Evaluation of Ion Concentrations in Laser Mass-Spectrometric Analysis with Photographic Recording

  • Published:
Journal of Analytical Chemistry Aims and scope Submit manuscript

Abstract

Methods for evaluating concentrations in analysis with the use of an EMAL-2 laser energy–mass analyzer are described. Analytical signals are calculated using the integrated intensity of spectral lines. The characteristic curve of a photographic emulsion is approximated by the function \(F(x) = \int_{ - \infty }^a {e^{ - x^2 } } dx\). The possibility of taking into account doubly and triply charged ions in the evaluation of concentrations is analyzed. It is shown that taking into account multiply charged ions reduces the relative root-mean-square deviation from 0.18 to 0.03.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

REFERENCES

  1. Trace Analysis by Mass Spectrometry, Ahearn A.J., Ed., New York and London: Academic Press, 1972. Translated under the title Mass-spektrometricheskii metod opredeleniya sledov, Moscow: Mir, 1975.

    Google Scholar 

  2. Ramendik, G.I., Elementnyi mass-spektrometricheskii analiz (Element Mass-Spectrometric Analysis), Moscow: Khimiya, 1993, p. 159.

    Google Scholar 

  3. Bykovskii, Yu.A.,Gladkov, V.P., andKuznetsov, G.B., Nauchnaya sessiya MIFI-99. Sbornik nauchnykh trudov (Scientific Session of Moscow Engineering Physics Institute MIFI-99. Collection of Scientific Works), Moscow: Mosk. Ingh.-Fiz. Inst., 1999, vol. 3, p. 145.

    Google Scholar 

  4. Kouznetsov, G.B., 16 Journées Francaises de Spectrométrie de Mass, France, Nancy, Session E: Instrumentation, p. 49.

  5. Potapov, M.A.,Chupakhin, M.S.,Etinger, A.G., andFalin, V.N., Zh. Anal. Khim., 1983, vol. 38, no. 4, p. 592.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Bykovskii, Y.A., Gladkov, V.P. & Kuznetsov, G.B. Evaluation of Ion Concentrations in Laser Mass-Spectrometric Analysis with Photographic Recording. Journal of Analytical Chemistry 56, 156–159 (2001). https://doi.org/10.1023/A:1009450820155

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1023/A:1009450820155

Keywords

Navigation