Biomedical Engineering

, Volume 38, Issue 3, pp 120–127 | Cite as

Passive Propagation of Transmembrane Potential Induced by Intrinsic Capacitances of Myocardium Bioelectrolytes during Its Electrical Defibrillation

  • S. N. Rybkin
  • S. V. Selishchev
Article
  • 16 Downloads

Keywords

Intrinsic Capacitance Passive Propagation Electrical Defibrillation 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

REFERENCES

  1. 1.
    L. A. Bokeriya and A. Sh. Revishvili, In: Proc. Sci.-Pract. Conf. Electrostimulation-2002, Moscow (2002), pp. 9-11.Google Scholar
  2. 2.
    L. D. Landau and E. M. Lifshits, Electrodynamics of Continuous Media [in Russian], Moscow (1982).Google Scholar
  3. 3.
    S. V. Selishchev, In: Proc. Sci.-Pract. Conf. Electro-stimulation-2002, Moscow (2002).Google Scholar
  4. 4.
    Ya. P. Terletskii and Yu. P. Rybakov, Electrodynamics [in Russian], Moscow (1980).Google Scholar
  5. 5.
    I. R. Efimov, F. Aguel, Y. Cheng, et al., Am. J. Physiol. Heart Circ. Physiol., 279, H1055-H1070 (2000).Google Scholar
  6. 6.
    E. Entcheva, N. A. Trayanova, and F. J. Claydon, IEEE Trans. Biomed. Eng., 46, No. 3, 260-270 (1999).Google Scholar
  7. 7.
    M. G. Fisher, IEEE Trans. Biomed. Eng., 44, No. 1, 10-18 (1997).Google Scholar
  8. 8.
    L. A. Geddes and W. Wavel, Biomed. Instrument. Technol., 34, 39-54 (2000).Google Scholar
  9. 9.
    C. S. Heriquez and R. Plonsey, IEEE Trans. Biomed. Eng., 37, No. 9, 850-860 (1990).Google Scholar
  10. 10.
    L. Tung, Optical Mapping of Cardiac Excitation and Arrhythmias, New York (2001), pp. 313-332.Google Scholar
  11. 11.
    D. M. Langrill and B. J. Roth, IEEE Trans. Biomed. Eng., 48, No. 10, 1207-1211 (2001).Google Scholar
  12. 12.
    G. Nighswonger, In: Medical Device and Diagnostic Industry, No. 3 (2001) (www.devicelink.com). Google Scholar
  13. 13.
    R. Plonsey and R. C. Barr, IEEE Eng. Med. Biol., 17, No. 5, 130-137 (1998).Google Scholar
  14. 14.
    A. Pumir and V. I. Krinsky, Physica D., 91, 205-219 (1996).Google Scholar
  15. 15.
    B. Rigaud, L. Hamzaoui, M. R. Frikha, et al., Physiol. Meas., 16, A15-A28 (1995).Google Scholar
  16. 16.
    S. V. Selishchev, In: EMBEC'02, Vol. 1 (2002), pp. 712-713.Google Scholar
  17. 17.
    E. A. Sobie, R. C. Susil, and L. Tung, Biophys. J., 73, 1410-1423 (1997).Google Scholar
  18. 18.
    N. A. Trayanova, B. J. Roth, and L. J. Malden, IEEE Trans. Biomed. Eng., 40, No. 9, 899-908 (1993).Google Scholar
  19. 19.
    N. A. Trayanova, Herzshr. Elektrophys., No. 10, 137-148 (1999).Google Scholar
  20. 20.
    J.-Z. Tsai, J. A. Will, S. H. Van-Stelle, et al., IEEE Trans. Biomed. Eng., 49, No. 5, 472-483 (2002).Google Scholar

Copyright information

© Plenum Publishing Corporation 2004

Authors and Affiliations

  • S. N. Rybkin
    • 1
  • S. V. Selishchev
    • 1
  1. 1.Moscow State Institute of Electronic EngineeringMoscowRussia

Personalised recommendations