Abstract
A simple and robust impulse-driven droplet deposition system was developed for off-line liquid chromatography matrix-assisted laser desorption ionization mass spectrometry (LC-MALDI MS). The system uses a solenoid operated with a pulsed voltage power supply to generate impulses that dislodge the hanging droplets from the LC outlet directly to a MALDI plate via a momentum transfer process. There is no contact between the LC outlet and the collection surface. The system is compatible with solvents of varying polarity and viscosity, and accommodates the use of hydrophobic and hydrophilic MALDI matrices. MALDI spots are produced on-line with the separation, and do not require further processing before MS analysis. It is shown that high quality MALDI spectra from 5 fmol of pyro-Glu-fibrinopeptide deposition after LC separation could be obtained using the device, indicating that there was no sample loss in the interface. To demonstrate the analytical performance of the system as a proteome analysis tool, a range of BSA digest concentrations covering about 3 orders of magnitude, from 5 fmol to 1 pmol, were analyzed by LC-MALDI quadrupole time-of-flight MS, yielding 6 and 57% amino acid sequence coverage, respectively. In addition, a complex protein mixture of an E. coli cell extract was tryptically digested and analyzed by LC-MALDI MS, resulting in the detection of a total of 409 unique peptides from 100 fractions of 15-s intervals.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Lilley, K. S.; Razzaq, A.; Dupree, P. Two-dimensional gel electrophoresis: Recent advances in sample preparation, detection, and quantitation. Curr. Opin. Chem. Biol. 2002, 6, 46–50.
Harry, J. L.; Wilkins, M. R.; Herbert, B. R.; Packer, N. H.; Gooley, A. A.; Williams, K. L. Proteomics: Capacity versus utility. Electrophoresis 2000, 21, 1071–1081.
Santoni, V.; Molloy, M.; Rabilloud, T. Membrane proteins and proteomics: Un amour impossible?. Electrophoresis 2000, 21, 1054–1070.
Gygi, S. P.; Corthals, G. L.; Zhang, Y.; Rochon, Y.; Aebersold, R. Evaluation of two-dimensional gel electrophoresis-based proteome analysis technology. Proc. Natl. Acad. Sci. U.S.A. 2000, 97, 9390–9395.
Opiteck, G. J.; Jorgenson, J. W.; Anderegg, R. J. Two-dimensional SEC/RPLC coupled to mass spectrometry for the analysis of peptides. Anal. Chem. 1997, 69, 2283–2291.
Simpson, D. C.; Smith, R. D. Combining capillary electrophoresis with mass spectrometry for applications in proteomics. Electrophoresis 2005, 26, 1291–1305.
Davis, M. T.; Lee, T. D. Variable flow liquid chromatography tandem mass spectrometry and the comprehensive analysis of complex protein digest mixtures. J. Am. Soc. Mass Spectrom. 1997, 8, 1059–1069.
Martin, S. E.; Shabanowitz, J.; Hunt, D. F.; Marto, J. A. Subfemtomole MS and MS/MS peptide sequence analysis using nano-HPLC micro-ESI Fourier transform ion cyclotron resonance mass spectrometry. Anal. Chem. 2000, 72, 4266–4274.
Li, L.; Wang, A. P. L.; Coulson, L. D. Continuous-flow matrix-assisted laser desorption ionization mass spectrometry. Anal. Chem. 1993, 65, 493–495.
Nagra, D. S.; Li, L. Liquid chromatography-time-of-flight mass spectrometry with continuous-flow matrix-assisted laser desorption ionization. J. Chromatogr. A. 1995, 711, 235–345.
Whittal, R. M.; Russon, L. M.; Li, L. Development of liquid chromatography-mass spectrometry using continuous-flow matrix-assisted laser desorption ionization time-of-flight mass spectrometry. J. Chromatogr. A 1998, 794, 367–375.
He, L.; Liang, L.; Lubman, D. M. Continuous-flow MALDI mass spectrometry using an ion-trap reflection time-of-flight detector. Anal. Chem. 1995, 67, 4127–4132.
Chang, S. Y.; Yeung, E. S. Laser vaporization/ionization interface for capillary electrophoresis time-of-flight mass spectrometry. Anal. Chem. 1997, 69, 2251–2257.
Zhan, Q.; Gusev, A.; Hercules, D. M. A novel interface for on-line coupling of liquid capillary chromatography with matrix-assisted laser desorption/ionization detection. Rapid Commun. Mass Spectrom. 1999, 13, 2278–2283.
Murray, K. K.; Russel, D. H. Liquid sample introduction for matrix-assisted laser desorption ionization. Anal. Chem. 1993, 65, 2534–2537.
Fei, X.; Wei, G.; Murray, K. K. Aerosol MALDI with a reflectron time-of-flight mass spectrometer. Anal. Chem. 1996, 68, 1143–1147.
Murray, K. K. Coupling matrix-assisted laser desorption/ionization to liquid separations. Mass Spectrom. Rev. 1997, 16, 283–299.
Orsnes, H.; Graf, T.; Degn, H.; Murray, K. K. A rotating ball inlet for on-line MALDI mass spectrometry. Anal. Chem. 2000, 72, 251–254.
Zhang, X.; Narcisse, D. A.; Murray, K. K. On-line single droplet deposition for MALDI mass spectrometry. J. Am. Soc. Mass Spectrom. 2004, 15, 1471–1477.
Mukhopadhyay, R. The automated union of LC and MALDI MS. Anal. Chem. 2004, 77, 150A-152A.
Wall, D. B.; Berger, S. J.; Finch, J. W.; Cohen, S. A.; Richardson, K.; Chapman, R.; Drabble, D.; Brown, J.; Gostick, D. Continuous sample deposition from reversed-phase liquid chromatography to tracks on a matrix-assisted laser desorption/ionization precoated target for the analysis of protein digest. Electrophoresis 2002, 23, 3193–3204.
Fung, K. Y. C.; Askovic, S.; Basile, F.; Duncan, M. W. A simple and inexpensive approach to interfacing high-performance liquid chromatography and matrix-assisted laser desorption/ionization-time of flight-mass spectrometry. Proteomics 2004, 4, 3121–3127.
Preisler, J.; Hu, P.; Rejtar, T.; Karger, B. L. Capillary electrophoresis matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using a vacuum deposition interface. Anal. Chem. 2000, 72, 4785–4795.
Chen, H.; Rejtar, T.; Andreev, V.; Moskovets, E.; Karger, B. L. High-speed, high-resolution monolithic capillary LC-MALDI MS using an off-line continuous deposition interface for proteomic analysis. Anal. Chem. 2005, 77, 2323–2331.
Griffin, T. J.; Gygi, S. P.; Rist, B.; Aebersold, R.; Loboda, A.; Jilkine, A.; Ens, W.; Standing, K. G. Quantitative proteomic analysis using a MALDI quadrupole time-of-flight mass spectrometer. Anal. Chem. 2001, 73, 978–986.
Bodnar, W. M.; Blackburn, R. K.; Krise, J. M.; Moseley, M. A. Exploiting the complementary nature of LC/MALDI/MS/MS and LC/ESI/MS/MS for increased proteome coverage. J. Am. Soc. Mass Spectrom. 2003, 14, 971–979.
Parker, K. C.; Patterson, D.; Williamson, B.; Marchese, J.; Graber, A.; He, F.; Jacobson, A.; Juhasz, P.; Martin, S. Depth of proteome issues—A yeast isotope-coded affinity tag reagent study. Mol. Cell. Proteom. 2004, 3, 625–659.
Tegeler, T. J.; Mechref, Y.; Boraas, K.; Reilly, J. P.; Novotny, M. V. Microdeposition device interfacing capillary electrochromatography and microcolumn liquid chromatography with matrix-assisted laser desorption/ionization mass spectrometry. Anal. Chem. 2004, 76, 6698–6706.
Mirgorodskaya, E.; Braeuer, C.; Fucini, P.; Lehrach, H.; Gobom, J. Nanoflow liquid chromatography coupled to matrix-assisted laser desorption/ionization mass spectrometry: Sample preparation, data analysis, and application to the analysis of complex peptide mixtures. Proteomics 2005, 5, 399–408.
Miliotis, T.; Kjellstrom, S.; Nilsson, J.; Laurell, T.; Edholm, L.; Marko-Varga, G. Capillary liquid chromatography interfaced to matrix-assisted laser desorption/ionization time-of-flight mass spectrometry using an on-line coupled piezoelectric flow-through microdispenser. J. Mass Spectrom. 2000, 35, 369–377.
Ekstrom, S.; Nisson, J.; Helldin, G.; Laurell, T.; Marko-Varga, G. Disposable polymeric high-density nanovial arrays for matrix assisted laser desorption/ionization-time of flight-mass spectrometry: II Biological applications. Electrophoresis 2001, 22, 3987–3992.
Laurell, T.; Nisson, J.; Marko-Varga, G. Silicon microstructures for high-speed and high-sensitivity protein identifications. J. Chromatogr. B 2001, 752, 217–232.
Ericson, C.; Phung, Q. T.; Horn, D. M.; Peters, E. C.; Fitchett, J. R.; Ficarro, S. B.; Salomon, A. R.; Brill, L. M.; Brock, A. An automated noncontact deposition interface for liquid chromatography matrix-assisted laser desorption/ionization mass spectrometry. Anal. Chem. 2003, 75, 2309–2315.
Bogan, M. J.; Agnes, G. R. Preliminary investigation of electrodynamic charged droplet processing to couple capillary liquid chromatography with matrix-assisted laser desorption/ionization mass spectrometry. Rapid Commun. Mass Spectrom. 2004, 18, 2673–2681.
Zhang, B.; McDonald, C.; Li, L. Combining liquid chromatography with MALDI mass spectrometry using a heated droplet interface. Anal. Chem. 2004, 76, 992–1001.
Ji, C. J.; Li, L. Quantitative proteome analysis using differential stable isotopic labeling and microbore LC-MALDI MS and MS/MS. J. Proteome Res. 2005, 4, 734–742.
Ji, C. J.; Li, L. J.; Gebre, M.; Pasdar, M.; Li, L. Identification and quantification of differentially expressed proteins in E-cadherin deficient SCC9 cells and SCC9 transfectants expressing E-cadherin by dimethyl isotope labeling, LC-MALDI MS and MS/MS. J. Proteome Res. 2005, 4, 1419–1426.
Ji, C. J.; Guo, N.; Li, L. Differential dimethyl labeling of N-termini of peptides after guanidination for proteome analysis. J. Proteome Res. 2005, 4, 2099–2108.
Li, N.; Wang, N.; Zheng, J. X.; Liu, X. M.; Lever, O. M.; Erickson, P. M.; Li, L. Characterization of human tear proteome using multiple proteomic analysis techniques. J. Proteome Res. 2005, 4, 2052–2061.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published online January 27, 2006
Rights and permissions
About this article
Cite this article
Young, J.B., Li, L. An impulse-driven liquid-droplet deposition interface for combining LC with MALDI MS and MS/MS. The official journal of The American Society for Mass Spectrometry 17, 325–334 (2006). https://doi.org/10.1016/j.jasms.2005.11.018
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1016/j.jasms.2005.11.018