Abstract
Charge reduction electrospray mass spectrometry (CREMS) reduces the charge states of electrospray-generated ions, which concentrates the ions from a protein into fewer peaks spread over a larger m/z range, thereby increasing peak separation and decreasing spectral congestion. An optimized design for a CREMS source is described that provides an order-of-magnitude increase in sensitivity compared to previous designs and provides control over the extent of charge reduction. Either a corona discharge or an α-particle source was employed to generate anions that abstract protons from electrosprayed protein cations. These desired ion/ion proton transfer reactions predominated, but some oxidation and ion-attachment reactions also occurred, leading to new peaks or mass-shifted broader peaks while decreasing signal intensity. The species producing these deleterious side-reactions were identified, and conditions were found that prevented their formation. Spectrometer m/z biases were examined because of their effect upon the signal intensity of higher m/z charge-reduced protein ions. The utility of this atmospheric pressure CREMS was demonstrated using a cell lysate fraction from E. coli. The spectral simplification afforded by CREMS reveals more proteins than are observed without charge reduction.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Karas, M.; Bachmann, D.; Bahr, U.; Hillenkamp, F. Matrix-Assisted Ultraviolet-Laser Desorption of Nonvolatile Compounds. Int. J. Mass Spectrom. Ion Processes 1987, 78, 53–68.
Hillenkamp, F.; Karas, M.; Beavis, R. C.; Chait, B. T. Matrix-Assisted Laser Desorption Ionization Mass-Spectrometry of Biopolymers. Anal. Chem. 1991, 63, A1193-A1202.
Fenn, J. B.; Mann, M.; Meng, C. K.; Wong, S. F.; Whitehouse, C. M. Electrospray Ionization for Mass-Spectrometry of Large Biomolecules. Science 1989, 246, 64–71.
Smith, R. D.; Loo, J. A.; Loo, R. R. O.; Busman, M.; Udseth, H. R. Principles and Practice of Electrospray Ionization-Mass-Spectrometry for Large Polypeptides and Proteins. Mass Spectrom. Rev. 1991, 10, 359–451.
Smith, R. D.; Cheng, X.; Bruce, J. E.; Hofstadler, S. A.; Anderson, G. A. Trapping, Detection, and Reaction of Very Large Single Molecular-Ions by Mass-Spectrometry. Nature 1994, 369, 137–139.
Stephenson, J. L. Jr.; McLuckey, S. A. Ion/Ion Reactions for Oligopeptide Mixture Analysis: Application to Mixtures Comprised of 0.5–100 kDa Components. J. Am. Soc. Mass Spectrom. 1998, 9, 585–596.
Hayter, J. R.; Robertson, D. H. L.; Gaskell, S. J.; Beynon, R. J. Proteome Analysis of Intact Proteins in Complex Mixtures. Mol. Cell. Proteomics 2003, 2, 85–95.
Li, W. Q.; Hendrickson, C. L.; Emmett, M. R.; Marshall, A. G. Identification of Intact Proteins in Mixtures by Alternated Capillary Liquid Chromatography Electrospray Ionization and LC ESI Infrared Multiphoton Dissociation Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Anal. Chem. 1999, 71, 4397–4402.
Lee, S. W.; Berger, S. J.; Martinovic, S.; Pasa-Tolic, L.; Anderson, G. A.; Shen, Y. F.; Zhao, R.; Smith, R. D. Direct Mass Spectrometric Analysis of Intact Proteins of the Yeast Large Ribosomal Subunit Using Capillary LC/FTICR. Proc. Natl. Acad. Sci. U.S.A. 2002, 99, 5942–5947.
Meng, F. Y.; Cargile, B. J.; Patrie, S. M.; Johnson, J. R.; McLoughlin, S. M.; Kelleher, N. L. Processing Complex Mixtures of Intact Proteins for Direct Analysis by Mass Spectrometry. Anal. Chem. 2002, 74, 2923–2929.
McLuckey, S. A.; Stephenson, J. L. Jr. Ion/Ion Chemistry of High-Mass Multiply Charged Ions. Mass Spectrom. Rev. 1998, 17, 369–407.
He, M.; McLuckey, S. A. Charge Permutation Reactions in Tandem Mass Spectrometry. J. Mass Spectrom. 2004, 39, 1231–1259.
Pitteri, S. J.; McLuckey, S. A. Recent Developments in the Ion/Ion Chemistry of High-Mass Multiply Charged ions. Mass Spectrom. Rev. 2005, Published online,
Ikonomou, M. G.; Kebarle, P. An Ion-Source with which Ions Produced by Electrospray can be Subjected to Ion Molecule Reactions at Intermediate Pressures (10–100 Torr)—Deprotonation of Polyprotonated Peptides. Int. J. Mass Spectrom. Ion Processes 1992, 117, 283–298.
McLuckey, S. A.; Vanberkel, G. J.; Glish, G. L. Reactions of Dimethylamine with Multiply Charged Ions of Cytochrome-c. J. Am. Chem. Soc. 1990, 112, 5668–5670.
Loo, R. R. O.; Smith, R. D. Investigation of the Gas-Phase Structure of Electrosprayed Proteins Using Ion-Molecule Reactions. J. Am. Soc. Mass Spectrom. 1994, 5, 207–220.
Stephenson, J. L. Jr.; McLuckey, S. A. Ion/Ion Reactions in the Gas Phase: Proton Transfer Reactions Involving Multiply-Charged Proteins. J. Am. Chem. Soc. 1996, 118, 7390–7397.
Reid, G. E.; Shang, H.; Hogan, J. M.; Lee, G. U.; McLuckey, S. A. Gas-Phase Concentration, Purification, and Identification of Whole Proteins from Complex Mixtures. J. Am. Chem. Soc. 2002, 124, 7353–7362.
Scalf, M.; Westphall, M. S.; Krause, J.; Kaufman, S. L.; Smith, L. M. Controlling Charge States of Large Ions. Science 1999, 283, 194–197.
Scalf, M.; Westphall, M. S.; Smith, L. M. Charge Reduction Electrospray Mass Spectrometry. Anal. Chem. 2000, 72, 52–60.
Ebeling, D. D.; Westphall, M. S.; Scalf, M.; Smith, L. M. Corona Discharge in Charge Reduction Electrospray Mass Spectrometry. Anal. Chem. 2000, 72, 5158–5161.
Ebeling, D. D.; Westphall, M. S.; Scalf, M.; Smith, L. M. A Cylindrical Capacitor Ionization Source: Droplet Generation and Controlled Charge Reduction for Mass Spectrometry. Rapid Commun. Mass Spectrom. 2001, 15, 401–405.
Schneider, B. B.; Baranov, V. I.; Javaheri, H.; Covey, T. R. Particle Discriminator Interface for Nanoflow ESI-MS. J. Am. Soc. Mass Spectrom. 2003, 14, 1236–1246.
Tanner, S. D.; Douglas, D. J.; French, J. B. Gas and Ion Dynamics of a 3-Aperture Vacuum Interface for Inductively-Coupled Plasma-Mass Spectrometry. Appl. Spectrosc. 1994, 48, 1373–1378.
Lu, Q.; Koropchak, J. A. Corona Discharge Neutralizer for Electrospray Aerosols Used with Condensation Nucleation Light-Scattering Detection. Anal. Chem. 2004, 76, 5539–5546.
Loeb, L. B. Recent Developments in Analysis of the Mechanisms of Positive Coronas in Air. J. Appl. Phys. 1948, 19, 882–897.
Carroll, D. I.; Dzidic, I.; Horning, E. C.; Stillwell, R. N. Atmospheric-Pressure Ionization Mass-Spectrometry. Appl. Spectrosc. Rev. 1981, 17, 337–406.
Yamashita, M.; Fenn, J. B. Negative-Ion Production with the Electrospray Ion-Source. J. Phys. Chem. 1984, 88, 4671–4675.
Nikolaev, E.; Riter, L. S.; Laughlin, B. C.; Handberg, E.; Cooks, R. G. Trace Analysis of Organics in Air by Corona Discharge Atmospheric Pressure Ionization Using an Electrospray Ionization Interface. Eur. J. Mass Spectrom 2004, 10, 197–204.
Skalny, J. D.; Mikoviny, T.; Matejcik, S.; Mason, N. J. An Analysis of Mass Spectrometric Study of Negative Ions Extracted from Negative Corona Discharge in air. Int. J. Mass Spectrom. 2004, 233, 317–324.
Guilhaus, M.; Selby, D.; Mlynski, V. Orthogonal Acceleration Time-of-Flight Mass Spectrometry. Mass Spectrom. Rev. 2000, 19, 65–107.
Chen, X.; Westphall, M. S.; Smith, L. M. Mass Spectrometric Analysis of DNA Mixtures: Instrumental Effects Responsible for Decreased Sensitivity with Increasing Mass. Anal. Chem. 2003, 75, 5944–5952.
Geno, P. W.; Macfarlane, R. D. Secondary-Electron Emission Induced by Impact of Low-Velocity Molecular-Ions on a Microchannel Plate. Int. J. Mass Spectrom. Ion Processes 1989, 92, 195–210.
Westmacott, G.; Frank, M.; Labov, S. E.; Benner, W. H. Using a Superconducting Tunnel Junction Detector to Measure the Secondary Electron Emission Efficiency for a Microchannel Plate Detector Bombarded by Large Molecular Ions. Rapid Commun. Mass Spectrom. 2000, 14, 1854–1861.
Busman, M.; Sunner, J.; Vogel, C. R. Space-Charge-Dominated Mass-Spectrometry Ion Sources—Modeling and Sensitivity. J. Am. Soc. Mass Spectrom. 1991, 2, 1–10.
Houston, P. L. Chemical Kinetics and Reaction Dynamics McGraw-Hill: Boston, 2001, 34–47.
Stephenson, J. L. Jr.; Van Berkel, G. J.; McLuckey, S. A. Ion-Ion Proton Transfer Reactions of Bio-Ions Involving Noncovalent Interactions: Holomyoglobin. J. Am. Soc. Mass Spectrom. 1997, 8, 637–644.
McLuckey, S. A.; Stephenson, J. L. Jr.; Asano, K. G. Ion/Ion Proton-Transfer Kinetics: Implications for Analysis of Ions Derived from Electrospray of Protein Mixtures. Anal. Chem. 1998, 70, 1198–1202.
Maleknia, S. D.; Brenowitz, M.; Chance, M. R. Millisecond Radiolytic Modification of Peptides by Synchrotron X-rays Identified by Mass Spectrometry. Anal. Chem. 1999, 71, 3965–3973.
Wong, J. W. H.; Maleknia, S. D.; Downard, K. M. Study of the Ribonuclease-S-Protein-Peptide Complex Using a Radical Probe and Electrospray Ionization Mass Spectrometry. Anal. Chem. 2003, 75, 1557–1563.
Maleknia, S. D.; Chance, M. R.; Downard, K. M. Electrospray-Assisted Modification of Proteins: A Radical Probe of Protein Structure. Rapid Commun. Mass Spectrom. 1999, 13, 2352–2358.
Mirza, U. A.; Chait, B. T. Effects of Anions on the Positive Ion Electrospray Ionization Mass Spectra of Peptides and Proteins. Anal. Chem. 1994, 66, 2898–2904.
Stephenson, J. L. Jr.; McLuckey, S. A. Gaseous Protein Cations are Amphoteric. J. Am. Chem. Soc. 1997, 119, 1688–1696.
Seinfeld, J. H.; Pandis, S. N. Atmospheric Chemistry and Physics: From Air Pollution to Climate Change; Wiley: New York 1998; 234–336.
Cooper, D. W.; Reist, P. C. Neutralizing Charged Aerosols with Radioactive Sources. J. Colloid Interface Sci. 1973, 45, 17–26.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published online September 28, 2005
Rights and permissions
About this article
Cite this article
Frey, B.L., Lin, Y., Westphall, M.S. et al. Controlling gas-phase reactions for efficient charge reduction electrospray mass spectrometry of intact proteins. J Am Soc Mass Spectrom 16, 1876–1887 (2005). https://doi.org/10.1016/j.jasms.2005.07.019
Received:
Revised:
Accepted:
Issue Date: