Abstract
This article presents a comparative study of the performance, operational, and instrumental characteristics of AP and vacuum MALDI for the analysis of peptides and protein digests. Spectra generated with the two ion sources were surprisingly similar, both qualitatively and quantitatively, with vacuum MALDI generating ion count rates that were approximately a factor of 2 greater than those generated with AP MALDI on this system. Even though the peptide signals were 2X greater with vacuum MALDI, the background intensities also increased by a similar amount, leading to approximately equivalent signal/background ratios for digests and peptide mixtures. The results suggest that when AP MALDI conditions are properly optimized, the sensitivity can approach that of vacuum MALDI. However, AP MALDI performance is critically affected by source gas flows, potentials, and temperature, making it operationally more complex. In addition, evidence is provided for thermal degradation of samples stored on a target plate within a heated AP MALDI ion source. An improved interface for atmosphere to vacuum ion transfer substantially improved these characteristics.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Tanaka, K.; Ido, Y.; Akita, S.; Yoshida, Y; Yoshida T. Proceedings of the 2nd Japan-China Joint Symposium on Mass Spectrometry; September, 1987, Osaka, Japan.
Karas, M.; Hillenkamp, F. Laser Desorption Ionization of Proteins with Molecular Masses Exceeding 10,000 Daltons. Anal. Chem. 1988, 60, 2299–2301.
Colby, S. M.; King, T. B.; Reilly, J. P. Improving the Resolution of Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry by Exploiting the Correlation Between Ion Position and Velocity. Rapid Commun. Mass Spectrom. 1994, 8, 865–868.
Vestal, M. L.; Juhasz, P.; Martin, S. A. Delayed Extraction Matrix-Assisted Laser-Desorption Time-of-Flight Mass Spectrometry. Rapid Commun. Mass Spectrom. 1995, 9, 1044–1050.
Brown, R. S.; Lennon, J. J. Mass Resolution Improvement by Incorporation of Pulsed Ion Extraction in a Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometer. Anal. Chem. 1995, 67, 1998–2003.
Mamyrin, B. A.; Karataev, V. I.; Shmikk, D. V.; Zagulin, V. A. Sov. Phys. JETP 1973, 37, 45.
Qin, J.; Chait, B. T. Matrix-Assisted Laser Desorption Ion Trap Mass Spectrometry: Efficient Isolation and Effective Fragmentation of Peptide Ions. Anal. Chem. 1996, 68, 2108–2112.
Medzihradszky, K. F.; Campbell, J. M.; Baldwin, M. A.; Falick, A. M.; Juhasz, P.; Vestal, M. L.; Burlingame, A. L. The Characteristics of Peptide Collision-Induced Dissociation Using a High-Performance MALDI-TOF/TOF Tandem Mass Spectrometer. Anal. Chem. 2000, 72, 552–558.
Loboda, A. V.; Krutchinsky, A. N.; Bromirski, M.; Ens, W.; Standing, K. G. A Tandem Quadrupole/Time-of-Flight Mass Spectrometer with a Matrix-Assisted Laser Desorption/Ionization Source: Design and Performance. Rapid Commun. Mass Spectrom. 2000, 14, 104–1057.
Krutchinsky, A. N.; Loboda, A. V.; Spicer, V. L.; Dworschak, R.; Ens, W.; Standing, K. G. Orthogonal Injection of Matrix-Assisted Laser Desorption/Ionization Ions into a Time-of-Flight Spectrometer Through a Collisional Damping Interface. Rapid Commun. Mass Spectrom. 1998, 12, 508–518.
Douglas, D. J.; French, J. B. Collisional Focusing Effects in Radio Frequency Quadrupoles. J. Am. Soc. Mass Spectrom. 1992, 3, 398–408.
Loboda, A. V.; Krutchinsky, A. N.; Bromirski, M.; Ens, W.; Standing, K. G. A Tandem Quadrupole/Time-of-Flight Mass Spectrometer with a Matrix-Assisted Laser Desorption Ionization Source: Design and Performance. Rapid Commun. Mass Spectrom. 2000, 14, 1047–1057.
Verentchikov, A.; Smirnov, I.; Vestal, M. Proceedings of the 47th ASMS Conference on Mass Spectrometry and Allied Topics; June, 1999, Dallas, Texas.
Laiko, V. V.; Baldwin, M. A.; Burlingame, A. L. Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Mass Spectrometry. Anal. Chem. 2000, 72, 652–657.
Laiko, V. V.; Moyer, S. C.; Cotter, R. J. Atmospheric Pressure MALDI/Ion Trap Mass Spectrometry. Anal. Chem. 2000, 72, 5239–5243.
Doroshenko, V. M.; Laiko, V. V.; Taranenko, N. I.; Berkout, V. D.; Lee, H. S. Recent Developments in Atmospheric Pressure MALDI Mass Spectrometry. Int. J. Mass Spectrom. 2002, 221, 39–58.
Galicia, M. C.; Vertes, A.; Callahan, J. H. Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization in Transmission Geometry. Anal. Chem. 2002, 74, 1891–1895.
Moyer, S. C.; Cotter, R. J. Atmospheric Pressure MALDI. Anal. Chem. 2002, 74, 469A-476A.
Miller, C. A.; Yi, D.; Perkins, P. D. An Atmospheric Pressure Matrix-Assisted Laser Desorption/Ionization Ion Trap with Enhanced Sensitivity. Rapid Commun. Mass Spectrom. 2003, 17, 860–868.
Meza, J. E.; Yi, D.; Miller, C. A.; Perkins, P. D. Versatile Protein Identification Using AP-MALDI Ion Trap Mass Spectrometry. PharmaGenomics 2003, Nov./Dec., 29–40.
Wolfender, J. L.; Chu, F.; Ball, H.; Wolfender, F.; Fainzilber, M.; Baldwin, M. A.; Burlingame, A. L. Identification of Tyrosine Sulfation in Conus pennaceaus Conotoxins α-PnIB: Further Investigation of Labile Sulfo- and Phosphopeptides by Electrospray Matrix-assisted Laser Desorption/Ionization (MALDI) and Atmospheric Pressure MALDI Mass Spectrometry. J. Mass Spectrom. 1999, 34, 447–454.
Schneider, B. B.; Baranov, V. I.; Javaheri, H.; Covey, T. R. Particle Discriminator Interface for Nanoflow ESI-MS. J. Am. Soc. Mass Spectrom. 2003, 14, 1236–1246.
Lin, B.; Sunner, J. Ion Transport by Viscous Gas Flow Through Capillaries. J. Am. Soc. Mass Spectrom. 1994, 5, 873–885.
Tan, P. V.; Laiko, V. V.; Doroshenko, V. M. Atmospheric Pressure MALDI with Pulsed Dynamic Focusing for High Efficiency Transmission of Ions into a Mass Spectrometer. Anal. Chem. 2004, 76, 2462–2469.
Douglas, D. J.; French, J. B. Collisional Focusing Effects in Radio Frequency Quadrupoles. J. Am. Soc. Mass Spectrom. 1992, 3, 398–408.
Corr, J.; Covey, T. R.; Chau, T.; Kovarik, P.; Fisher, W. MALDI MS/MS on a Triple Quadrupole Mass Spectrometer: A New Technology for High Throughput Small Molecule Quantitation. Proceedings of the 51st ASMS Conference; Montreal, 2003.
Kovarik, P.; Corr, J.; Covey, T. R. Application of Orthogonal MALDI for Quantitation of Small Molecules using a Triple Quadrupole Mass Spectrometer. Proceedings of the 51st ASMS Conference; Montreal, 2003.
Tan, P. V.; Doroshenko, V. M.; Schneider, B. B.; Alary, J. F. AP/MALDI PDF on an ABI/SCIEX 4000 QTRAP. Lecture presented at the MassTech Users Meeting. Proceedings of the 52nd ASMS Conference; Nashville, TN, May, 2004.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published online December 9, 2004
Rights and permissions
About this article
Cite this article
Schneider, B.B., Lock, C. & Covey, T.R. AP and vacuum MALDI on a QqLIT instrument. J Am Soc Mass Spectrom 16, 176–182 (2005). https://doi.org/10.1016/j.jasms.2004.10.004
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/j.jasms.2004.10.004