Abstract
Thermoanalytical techniques are currently used for the analysis of additives contained in polymers that cannot be easily dissolved, extracted, or hydrolyzed. With these techniques, the polymers are heated to liberate the additives trapped in the polymer matrix. If the polymer is heated slowly, up to its thermal degradation, the technique is called temperature-programmed pyrolysis (TPPy). For TPPy experiments, mass spectrometry is generally used as the detection method. The ionization sources commonly used in mass spectrometry, such as CI and EI, can cause fragmentation during the ionization process. Fragmentation decreases the sensitivity of the molecular ions and increases the risks of interferences with the compounds coming from the matrix. An energy-tunable ionization technique, called metastable atom bombardment (MAB), is proposed for TPPy/MS experiments. With this ionization source, the energy of ionization depends on the metastable gas used. With low-energy metastable gases such as Xe or N2, fragmentation is reduced compared to CI, whereas with medium-energy metastable gases such as Ar or Kr, the fragmentation is similar to that observed with CI. TPPy/MAB-MS was performed on an unknown polyurethane-based car paint. The detection of molecular ions and characteristic fragments with MAB(N2) led to the identification of two light stabilizers: Bis(1,2,2,6,6-pentamethyl-4-piperidinyl)sebacate (BPPS) and 2-(2H-benzotriazol-2-yl)-4,6-di-tert-pentylphenol (PTPP). Using MAB(Ar) to simulate CI, the molecular ion and one of the two characteristic fragments of BPPS were not detected, thus confirming the advantage of using MAB(N2) ionization for TPPy/MS experiments.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Gächter, R.; Müller, H. Plastics Additives Handbook 4th ed; Hansa: Munich, 1993.
Bart, J. C. J. Polymer Additive Analysis at the Limits. Polym. Degrad. Stab. 2003, 82, 197–205.
Bart, J. C. J. Polymer/Additive Analysis by Flash Pyrolysis Techniques. J. Anal. Appl. Pyrolysis 2001, 58/59, 3–28.
Molt, K.; Ihlbrock, D. Principles and Applications of Quality Control by Near Infrared Spectroscopy Using the Example of Polymer Additives. Fresenius J. Anal. Chem. 1994, 348, 523–529.
Herrera, M.; Matuschek, G.; Kettrup, A. Fast Identification of Polymer Additives by Pyrolysis-Gas Chromatography/Mass Spectrometry. J. Anal. Appl. Pyrolysis 2003, 70, 35–42.
Faubert, D.; Paul, G. J. C.; Giroux, J.; Bertrand, M. J. Selective Fragmentation and Ionization of Organic Compounds Using an Energy-Tunable Rare-Gas Metastable Beam Source. Int. J. Mass Spectrom. Ion Processes 1993, 124, 69–77.
Siska, P. E. Molecular-Beam Studies of Penning Ionization. Rev. Mod. Phys. 1993, 65, 337–412.
Delacroix, J. L.; Matos Ferreira, C.; Ricard, A. Atomes et molécules métastables dans les gaz ionisés; Centre National de la Recherche Scientifique: Paris, 1975; p 21.
Slanger, T. G. In Reactions of Small Transient Species: Kinetics and Energetics; Fontijn, A.; Clyne, M. A. A., Ed.; Academic Press: New York, 1983; pp 293–302.
Faubert, D. Développement et application d’une source d’ionisation utilisant le bombardement par atomes métastables; Montreal University: Montreal, 1999; pp 135–137.
Ikonomou, M. G.; Rayne, S. Chromatographic and Ionization Properties of Polybrominated Diphenyl Ethers Using GC/High-Resolution MS with Metastable Atom Bombardment and Electron Impact Ionization. Anal. Chem. 2002, 74, 5263–5272.
Moore, S. Use of the Metastable Atom Bombardment (MAB) Ion Source for the Elimination of PCDE Interference in PCDD/PCDF analysis. Chemosphere 2002, 49, 121–125.
Letarte S.; Mousselmal M.; Faubert D.; Bertrand M. J. Use of MAB-MS for the Characterization of Bacteria. Proceedings of the 46th ASMS Conference on Mass Spectrometry and Allied Topics; Orlando, FL, 1998.
Forest A.; Martin P.; Faubert D.; Sanchez G.; Bertrand M. J. Evaluation of Py-MAB-TOF as a Technique for the Detection of Explosives by Direct Analysis of Soil Samples. Proceedings of the 48th ASMS Conference on Mass Spectrometry and Allied Topics; Long Beach, CA, 1998.
Martin P.; Forest A.; Peraldi O.; Bertrand M. J. A Benchtop Mass Spectrometer Optimized for Pyrolysis Mass Spectrometry: PY-MAB-TOF. Proceedings of the 48th ASMS Conference on Mass Spectrometry and Allied Topics; Long Beach, CA, 2000.
Funazukuri, T.; Hudgins, R. R.; Silverston, P. L. Product Distribution for Flash Pyrolysis of Cellulose in a Coil Pyrolyzer. J. Anal. Appl. Pyrolysis 1987, 10, 225–249.
Boutin, M.; Lesage, J.; Ostiguy, C.; Bertrand, M. J. Comparison of EI and Metastable Atom Bombardment Ionization for the Identification of Polyurethane Thermal Degradation Products. J. Anal. Appl. Pyrolysis 2003, 70, 505–517.
McLafferty, F. W.; Turecek, F. Interpretation of Mass Spectra 4th ed University Science Books: Sausalito, CA, 1993, pp 53, 185, 186.
Author information
Authors and Affiliations
Corresponding author
Additional information
Published online July 28, 2004
Rights and permissions
About this article
Cite this article
Boutin, M., Lesage, J., Ostiguy, C. et al. Temperature-programmed pyrolysis hyphenated with metastable atom bombardment ionization mass spectrometry (TPPy/MAB-MS) for the identification of additives in polymers. J Am Soc Mass Spectrom 15, 1315–1319 (2004). https://doi.org/10.1016/j.jasms.2004.05.011
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/j.jasms.2004.05.011