Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction

  • Original Articles
  • Published:
Journal of Nuclear Cardiology Aims and scope

Abstract

Background

The diagnostic value and incremental contribution of different noninvasive tests to the identification of coronary artery disease in 128 patients from a general population with intermediate pretest likelihood (48.0%) were determined by ordered logistic regression analysis and receiver-operating characteristic (ROC) curves.

Methods and Results

Patients referred for suspicion of coronary heart disease were submitted to bicycle exercise testing under clinical and electrocardiographic control. At peak exercise, first-pass radionuclide angiography was performed after injection of 99mTc-labeled sestamibi, followed by single-photon emission computed tomographic (SPECT) acquisition. A comparative rest study was obtained within 1 week, and qualitative and quantitative analysis was applied to assess the presence and extent of disease. With coronary angiography and 50% stenosis used as a standard, the discriminative accuracy of each test was calculated. The accuracies to diagnose coronary heart disease were 71.3%±4.7% for the bicycle test, 66.7%±5.3% for radionuclide angiography, and 81.6%±3.9% for the SPECT data. By ROC curves, the optimal criteria for positivity were determined for the visual and quantitative analysis for both presence and extent of coronary artery disease. Results of visual and quantitative SPECT were compared in terms of area under the ROC curves. The diagnostic performances showed no significant difference, ranging from 74.3% to 81.6%. The first-pass radionuclide angiographic and SPECT data were added progressively to the stress testing to evaluate their incremental diagnostic contribution. Only the addition of SPECT results significantly increased the accuracy to 85.6%±3.3% (p<0.0001).

Conclusion

Exercise electrocardiography and first-pass radionuclide angiography showed comparable accuracy to detect coronary artery disease. However, the combination of exercise testing and visual SPECT analytic data sufficed to ensure diagnostic accuracy, without significant benefit from the addition of other tests or the application of quantification.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Maddahi J, Garcia EV, Berman DS, Waxman A, Swan HJC, Forrester J. Improved noninvasive assessment of coronary artery disease by quantitative analysis of regional stress myocardial distribution and washout of thallium-201. Circulation 1981;64: 924–35.

    PubMed  CAS  Google Scholar 

  2. Kaul S, Boucher CA, Newell JB, et al. Determination of the quantitative thallium imaging variables that optimize, detection of coronary artery disease. J Am Coll Cardiol 1986;7:527–37.

    PubMed  CAS  Google Scholar 

  3. Kiat H, Maddahi J, Roy LT, et al. Comparison of technetium 99m methoxy isobutyl isonitrile and thallium 201 for evaluation of coronary artery disease by planar and tomographic methods. Am Heart J 1989;117:1–11.

    Article  PubMed  CAS  Google Scholar 

  4. Fintel DJ, Links JM, Brinker JA, Frank TL, Parker M, Becker LC. Improved diagnostic performance of thallium 201 single photon emission computerized tomography over planar imaging in the diagnosis of coronary artery disease: a receiver operating characteristic analysis. J Am Coll Cardiol 1989;13:600–12.

    PubMed  CAS  Google Scholar 

  5. DePuye EG, Garcia EV. Optimal specificity of thallium-201 SPECT through recognition of imaging artifacts. J Nucl Med 1989;30:441–9.

    Google Scholar 

  6. Wackers FJ. Artifacts in planar and SPECT myocardial perfusion imaging. Am J Cardiac Imaging 1992;6:42–58.

    CAS  Google Scholar 

  7. Patel R, Bushnell DL, Wagner R, Stumbris R. Frequency of false-positive septal defects on adenosine/201TI images in patients with left bundle branch block. Nucl Med Commun 1995;16:137–9.

    PubMed  CAS  Google Scholar 

  8. Borges-Neto S, Coleman RE, Potts JM, Jones RH. Combined exercise radionuclide angiography and single photon emission computed tomography perfusion studies for assessment of coronary artery disease. Semin Nucl Med 1991;21:223–9.

    Article  PubMed  CAS  Google Scholar 

  9. Pollock SG, Abbott RD, Boucher CA, Beller GA, Kaul S. Independent and incremental prognostic value of tests performed in hierarchical order to evaluate patients with suspected coronary artery disease: validation of models based on these tests. Circulation 1992;85:237–48.

    PubMed  CAS  Google Scholar 

  10. Bonow RO. Prognostic assessment in coronary artery disease: role of radionuclide angiography. J Nucl Cardiol 1994;1:280–91.

    Article  PubMed  CAS  Google Scholar 

  11. Mazzotta G, Pace L, Bonow RO. Risk stratification of patients with coronary artery disease and left ventricular dysfunction by exercise radionuclide angiography and exercise electrocardiography. J Nucl Cardiol 1994;1:529–36.

    Article  PubMed  CAS  Google Scholar 

  12. Avery PG, Hudson NM, Hubner PJB. Gated technetium-99m methoxy-isobutylisonitrile perfusion imaging. Int J Cardiol 1992; 35:227–34.

    Article  PubMed  CAS  Google Scholar 

  13. DePuey EG, Rozanski A. Gated Tc-99m sestamibi SPECT to characterize fixed defects as infarct or artifact. J Nucl Med 1995;36:952–5.

    PubMed  CAS  Google Scholar 

  14. Diamond GA, Forrester JS. Analysis of probability as an aid in the clinical diagnosis of coronary artery disease. N Engl J Med 1979;300:1350–8.

    PubMed  CAS  Google Scholar 

  15. Franken, PR, Dobbeleir AA, Ham HR, et al. Clinical usefulness of ultrashort-lived iridium-191m from a carbon-based generator system for the evaluation of the left ventricular function. J Nucl Med 1989;30:1025–31.

    PubMed  CAS  Google Scholar 

  16. Dobbeleir A, Franken PR, Ham HR, et al. Performance of a single crystal digital gamma camera for first pass cardiac studies. Nucl Med Commun 1991;12:27–34.

    Article  PubMed  CAS  Google Scholar 

  17. Franken PR, Vervaet A, Ranquin R, et al. Improvement in the efficacy of exercise first-pass radionuclide angiocardiography in detecting coronary artery disease and the effect of the patient age. Eur Heart J 1992;13:1189–94.

    PubMed  CAS  Google Scholar 

  18. Gibbons RJ. Rest and exercise radionuclide angiography for diagnosis in chronic ischemic heart disease. Circulation 1991;84: 93–9.

    Google Scholar 

  19. Dobbeleir A, Franken PR, Vandevivere J. A normalisation method for quantification of myocardial perfusion images independent of normal tissue localisation [abstract]. Eur J Nucl Med 1991;18:660.

    Google Scholar 

  20. SAS/STAT user’s guide, version 6. 4th ed. Cary, North Carolina: SAS Institute Inc, 1990.

  21. Hanley JA, McNeil BJ. The meaning and use of the area under a receiver operating characteristic (ROC) curve. Radiology 1982; 143:29–36.

    PubMed  CAS  Google Scholar 

  22. Metz CE. Basic principles of ROC analysis. Semin Nucl Med 1978;8:283–98.

    Article  PubMed  CAS  Google Scholar 

  23. Metz CE, Kronman HB. A test for the statistical significance of difference between ROC curves. In: Information processing in medical imaging. Paris: INSERM, 1979:647–60.

    Google Scholar 

  24. Metz CE, Wang PL, Kronman HB. A new approach for testing the significance of differences between ROC curves measured from correlated data. In: Information processing in medical imaging. The Haghe: M Nijhoff, 1984:432–45.

    Google Scholar 

  25. Patterson RE, Horowitz SF. Importance of epidemiology and biostatistics in deciding clinical strategies for using diagnostic tests: a simplified approach using examples from coronary artery disease. J Am Coll Cardiol 1989;13:1653–65.

    PubMed  CAS  Google Scholar 

  26. Di Bello V, Gori E, Bellina RC, et al. Incremental diagnostic value of dipyridamole echocardiography and exercise thallium-201 scintigraphy in the assessment of presence and extent of coronary artery disease. J Nucl Cardiol 1994;1:372–81.

    Article  PubMed  Google Scholar 

  27. Carini G, Di Pasquale G, Labanti G, et al. The incremental prognostic value of normal myocardial scintigraphy in patients with abnormal asymptomatic exercise testing [abstract]. Eur J Nucl Med 1994;21:S79.

    Google Scholar 

  28. Palmas W, Friedman JD, Kiat H, et al. Improved identification of multiple vessel coronary artery disease by addition of exercise wall motion analysis to Tc-99m sestamibi myocardial perfusion SPECT [abstract]. J Nucl Med 1993;34:130P.

    Google Scholar 

  29. Better N, Parker JA, Rocco T, Simons M, Gervino EV. The impact of the perfusion component of stress studies on clinical management [abstract]. Eur J Nucl Med 1994;21:S78.

    Google Scholar 

  30. Iskandrian AS, Ghods M, Helfeld H, Iskandrian B, Cave V, Heo J. The treadmill exercise score revisited: coronary angiography and thallium perfusion correlates. Am Heart J 1992;124:1581–6.

    Article  PubMed  CAS  Google Scholar 

  31. Jamar F, Topcuoglu R, Cauwe F, et al. Exercise gated planar myocardial perfusion imaging using technetium-99m sestamibi for the diagnosis of coronary artery disease: an alternative to exercise tomographic imaging. Eur J Nucl Med 1995;22:40–8.

    Article  PubMed  CAS  Google Scholar 

  32. Van Train KF, Garcia EV, Maddahi J, et al. Multicenter trial validation for quantitative analysis of same-day rest-stress technetium-99m-sestamibi myocardial tomograms. J Nucl Med 1994; 35:609–18.

    PubMed  Google Scholar 

  33. DePasquale EE, Nody AC, DePuey EG, et al. Quantitative rotational thallium-201 tomography for identifying and localizing coronary artery disease. Circulation 1988;77:316–27.

    PubMed  CAS  Google Scholar 

  34. Mahmarian JJ, Boyce TM, Goldberg RK, Cocanougher MK, Roberts R, Verani MS. Quantitative exercise thallium-201 single photon emission computed tomography for the enhanced diagnosis of ischemic heart disease. J Am Coll Cardiol 1990;15:318–29.

    Article  PubMed  CAS  Google Scholar 

  35. Wackers FJTh. Science, art, and artifacts: how important is quantification for the practicing physician interpreting myocardial perfusion studies? J Nucl Cardiol 1994;1:S109–17.

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Hambÿe, A.S., Vervaet, A., Lieber, S. et al. Diagnostic value and incremental contribution of bicycle exercise, first-pass radionuclide angiography, and 99mTc-labeled sestamibi single-photon emission computed tomography in the identification of coronary artery disease in patients without infarction. J Nucl Cardiol 3, 464–474 (1996). https://doi.org/10.1016/S1071-3581(96)90056-2

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1016/S1071-3581(96)90056-2

Key Words

Navigation