Abstract
Many performance parameters of Fourier transform ion cyclotron resonance (FT-ICR) mass spectrometry improve dramatically with increasing magnetic field. Our prior results from a 20 tesla resistive magnet showed that performance was limited by the large spatial inhomogeneity in spite of the high field. In this paper, we compare matrix-assisted laser desorption/ionization (MALDI) mass spectra at the same magnetic field for two resistive magnets with different field spatial homogeneity. In addition, we report MALDI spectra at 25 tesla—the highest magnetic field for FT-ICR to date. The first broadband FT-ICR mass spectrum [poly(ethylene glycol) 2000] from a resistive magnet is accurately fitted by the standard ICR mass calibration function.
References
Comisarow, M. B.; Marshall, A. G. Fourier Transform Ion Cyclotron Resonance Spectroscopy Chem. Phys. Lett. 1974, 25, 282–283.
Comisarow, M. B.; Marshall, A. G. Frequency-Sweep Fourier Transform Ion Cyclotron Resonance Spectroscopy Chem. Phys. Lett. 1974, 26, 489–490.
Trends in Analytical Chemistry 13, Special Issue: Fourier Transform Mass Spectrometry; Wilkins, C. L., Ed.; Elsevier: Amsterdam, 1994; pp 223–251.
McLafferty, F. W. High-Resolution Tandem FT Mass Spectrometry above 10 kDa. Acc. Chem. Res. 1994, 27, 379–386.
Marshall, A. G., Ed. Int. J. Mass Spectrom. Ion Processes. Special Issue: Fourier Transform Ion Cyclotron Resonance Mass Spectrometry 1996, 137/138, 1–410.
Laude, D. A.; Stevenson, E.; Robinson, J. M. Electrospray ionization/Fourier transform ion cyclotron resonance mass spectrometry In Electrospray Ionization Mass Spectrometry; R. B. Cole, Ed.; Wiley: New York, 1997; pp 291–319.
Marshall, A. G.; Hendrickson, C. L.; Jackson, G. S. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: A Primer. Mass Spectrom. Rev. 1998, 17, 1–35.
Amster, I. J. A Tutorial on Fourier Transform Mass Spectrometry. J. Mass Spectrom. 1996, 31, 1325–1337.
Dienes, T.; Pastor, S. J.; Schürch, S.; Scott, J. R.; Yao, J.; Cui, S.; Wilkins, C. L. Fourier Transform Mass Spectrometry—Advancing Years (1992–Mid 1996). Mass Spectrom. Rev. 1996, 15, 163–211.
Marshall, A. G.; Guan, S. Advantages of High Magnetic Field for FT-ICR Mass Spectrometry. Rapid Commun. Mass Spectrom. 1996, 10, 1819–1823.
Senko, M. W.; Hendrickson, C. L.; Pasa-Tolic, L.; Marto, J. A.; White, F. M.; Guan, S.; Marshall, A. G. Electrospray Ionization FT-ICR Mass Spectrometry at 9. 4 Tesla. Rapid Commun. Mass Spectrom. 1996, 10, 1824–1828.
Gorshkov, M. V.; Pasa-Tolic, L.; Udseth, H. R.; Anderson, G. A.; Huang, B. M.; Bruce, J. E.; C, P. D.; Hofstadler, S. A.; Tang, L.; Chen, L.-Z.; Willett, J. A.; Rockwood, A. L.; Sherman, M. S.; Smith, R. D. Electrospray Ionization-Fourier Transform Ion Cyclotron Resonance Mass Spectrometry at 11. 5 Tesla: Instrument Design and Initial Results. J. Am. Soc. Mass Spectrom. 1998, 9, 692–700.
Shi, S. D.-H.; Hendrickson, C. L.; Marshall, A. G. Counting Individual Sulfur Atoms in a Protein by Ultrahigh-Resolution Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: Experimental Resolution of Isotopic Fine Structure in Proteins. Proc. Natl. Acad. Sci. U. S. A. 1998, 95, 11532–11537.
Kelleher, N. L.; Senko, M. W.; Siegel, M. M.; McLafferty, F. W. Unit Resolution Mass Spectra of 112 kDa Molecules with 3 Da Accuracy. J. Am. Soc. Mass Spectrom. 1997, 8, 380–383.
Hendrickson, C. L.; Drader, J. J.; Laude, D. A., Jr.; Guan, S.; Marshall, A. G. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry in a 20 T Resistive Magnet. Rapid Commun. Mass Spectrom. 1996, 10, 1829–1832.
Brooks, J.; Crow, J. E.; Parkin, D. M.; Schneider-Muntau, H. J.; Sullivan, N. S. National High Magnetic Field Laboratory: Facilities and Scientific Opportunities. Physica B 1994, 197, 19–27.
Senko, M. W.; Canterbury, J. D.; Guan, S.; Marshall, A. G. A High-Performance Modular Data System for FT-ICR Mass Spectrometry. Rapid Commun. Mass Spectrom. 1996, 10, 1839–1844.
Drader, J. J.; Shi, S. D.-H.; Blakney, G. T.; Hendrickson, C. L.; Marshall, A. G.; Laude, D. A. Digital Quadrature Heterodyne Detection in FT-ICR MS In Proc. 46th American Society for Mass Spectrometry Annual Conference on Mass Spectrometry & Allied Topics. Amer. Soc. Mass Spectrom: Orlando, FL, 1998; p 910.
Alford, J. M.; Williams, P. E.; Trevor, D. J.; Smalley, R. E. Metal Cluster ICR. Combining Supersonic Metal Cluster Beam Technology with FT-ICR. Int. J. Mass Spectrom. Ion Processes 1986, 72, 33–51.
Wilson, M. N. Superconducting Magnets, Oxford University Press: Oxford, 1983.
Eyssa, Y. M.; Bird, M. D.; Gao, B. J.; Schneider-Muntau, H.-J. Design and Analysis of a 25 T Resistive NMR Magnet. IEEE Trans. Magn. 1996, 32, 2546–2549.
Comisarow, M. B. Signals, Noise, Sensitivity and Resolution in ICR Spectroscopy In Ion Cyclotron Resonance Spectrometry II; Hartmann, H.; Wanczek, K.-P., Eds.; Springer: Berlin, 1982; pp 484–513.
Ledford, E. B., Jr.; Rempel, D. L.; Gross, M. L. Space Charge Effects in Fourier Transform Mass Spectrometry. Mass Calibration. Anal. Chem. 1984, 56, 2744–2748.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Shi, S.D.H., Drader, J.J., Hendrickson, C.L. et al. Fourier transform ion cyclotron resonance mass spectrometry in a high homogeneity 25 tesla resistive magnet. J Am Soc Mass Spectrom 10, 265–268 (1999). https://doi.org/10.1016/S1044-0305(98)00152-4
Received:
Revised:
Accepted:
Issue Date: