Skip to main content
Log in

Identification of in vitro metabolites of indinavir by “intelligent automated LC-MS/MS” (INTAMS) utilizing triple quadrupole tandem mass spectrometry

  • Published:
Journal of the American Society for Mass Spectrometry

Abstract

In an effort to improve the efficiency of the TSQ 7000 LC-MS/MS system for identification of drug metabolites in biological matrices in support of drug discovery programs, a combination of instrument control language procedures for the Finnigan MAT TSQ 7000 mass spectrometer, referred to as INTAMS, were composed. INTAMS was designed to conduct unattended, automatic liquid chromatography/mass spectrometry (LC-MS) and LC-MS/MS analyses of drugs and metabolites in commonly encountered in vitro biological matrices. A novel peak detection algorithm was developed to automatically detect and record the pseudomolecular ions and retention times of chromatographic components, even if not fully resolved. This algorithm was used in combination with an automated technique for predicting the molecular weights of metabolites based on incremental changes of the molecular weight of the parent drug resulting from well-known biotransformation processes. When applied to a sample of an incubation mixture of the HIV protease inhibitor Indinavir with a rat liver S9 preparation, the results obtained by the automatic metabolite detection procedures for LC-MS and LC-MS/MS analyses in real time were the same as those which were determined manually, by a knowledgeable operator.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Gallop, M. A.; Barrett, R. W.; Dower, W. J.; Fodor, S. P.; Gordon, E. M. J. Med. Chem. 1994, 37, 1233–1251.

    Article  CAS  Google Scholar 

  2. Gordon, E. M.; Barrett, R. W.; Dower, W. J.; Fodor, S. P.; Gallop, M. A. J. Med. Chem. 1994, 37, 1385–1401.

    Article  CAS  Google Scholar 

  3. Humphrey, M. J. Drug Metab. Rev 1996, 28, 473–489.

    Article  CAS  Google Scholar 

  4. Halm, K. A.; Adkison, K. K.; Berman, J.; Shaffer, J. E.; Tong, Q. W.; Lee, F. W.; Unger, S. E. Proceedings of the 44th ASMS Annual Conference on Mass Spectrometry and Allied Topics; Portland, OR, May 1996; p 392.

  5. Olah, T. V.; McLoughlin, D. A.; Gilbert, J. D. Rapid Commun. Mass Spectrom. 1997, 11, 17–23.

    Article  CAS  Google Scholar 

  6. McLoughlin, D. A.; Olah, T. V.; Gilbert, J. D. J. Pharm. Biomed. Anal. 1997, 15, 1893–1901.

    Article  CAS  Google Scholar 

  7. Berman, J.; Halm, K. A.; Adkison, K. K.; Shaffer, J. E. J. Med. Chem. 1997, 40, 827–829.

    Article  CAS  Google Scholar 

  8. Rudewicz, P.; Straub, K. M. Anal. Chem. 1986, 58, 2928–22934.

    Article  CAS  Google Scholar 

  9. Mylchreest, I.; Wheeler, K.; Campbell, C. Finnigan MAT TSQ® Application Report 1995, #240.

  10. Cole, M. J.; Gauthier, J. W.; Luther, E. W.; Fouda, H. G. Proceedings of the 43rd ASMS Annual Conference on Mass Spectrometry and Allied Topics; Atlanta, GA, May 1995; p 569.

  11. Lin, J. H.; Chiba, M.; Balani, S. K.; Chen, I.-W.; Kwei, G. Y.-S.; Vastag, K. J.; Nishime, J. A. Drug Metab. Dispos 1996, 24, 1111–1120.

    CAS  Google Scholar 

  12. Balani, S. K.; Woolf, E. J.; Hoagland, V. L.; Sturgill, M. G.; Deutsch, P. J.; Yeh, K. C.; Lin, J. H. Drug. Metab. Dispos. 1996, 24, 1389–1394.

    CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Yu, X., Cui, D. & Davis, M.R. Identification of in vitro metabolites of indinavir by “intelligent automated LC-MS/MS” (INTAMS) utilizing triple quadrupole tandem mass spectrometry. J Am Soc Mass Spectrom 10, 175–183 (1999). https://doi.org/10.1016/S1044-0305(98)00132-9

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1016/S1044-0305(98)00132-9

Keywords

Navigation