We report the fabrication of a durable nonmetallized nanospray tip. This nanospray tip does not require complex preparation procedures such as chemical treatment, deposition of gold or SiOx vapor. It was fabricated by pulling a heated glass capillary of 1.1 mm internal diameter to produce a fine tip with an orifice of 10–15 µm in diameter. A 10 µm gold-plated tungsten wire was inserted through the capillary tip. This tungsten wire played a central role in the operation of this durable nanospray tip by providing electrical contact. This type of nanospray tip could withstand electrical discharges and sustained spraying of solution at nanoliter flow rate for more than 3 h. Using insulin (35 µM) and myoglobin (1 µM) solutions, useful mass spectrum could be acquired with low fmol sensitivity.
References
Fenn, J. B.; Mann, M.; Meng, C. K.; Wong, S. F.; Whitehouse, C. M. Science 1989, 246, 64.
Nohmi, T.; Fenn, J. B. J. Am. Chem. Soc. 1992, 114, 3241.
Banks, J. F.; Shen, S.; Whitehouse, C. M.; Fenn, J. B. Anal. Chem. 1994, 66, 406.
Le, J. C.; Hui, J.; Haniu, M.; Katta, V.; Rohde, M. F. J. Am. Soc. Mass Spectrom. 1997, 8, 703.
Wahl, J. H.; Gale, D. C.; Smith, R. D. J. Chromatogr A 1994, 659, 217.
Valskovic, G. A.; Kelleher, N. L.; McLafferty, F. W. Science 1996, 273, 1199.
Wilm, M. S.; Mann, M. Int. J. Mass Spectrom. Ion Processes 1994, 136, 167.
Wilm, M. S.; Mann, M. Anal. Chem. 1996, 68, 1.
Korner, R.; Wilm, M.; Morand, K.; Schubert, M.; Mann, M. J. Am. Soc. Mass Spectrom. 1996, 7, 150.
Valaskovic, G. A.; Kelleher, N. L.; Aaserud, D. J.; McLafferty, F. W. Anal. Chem. 1995, 67, 3802.
Kriger, M. S.; Cook, K. D.; Ramsey, R. S. Anal. Chem. 1995, 67, 385.
Valaskovic, G. A.; McLafferty, F. W. Rapid Commum. Mass Spectrom. 1996, 10, 825–828.
Kelly, J. F.; Ramaley, L.; Thibault, P. Anal. Chem. 1997, 69, 51–60.
Vanhoutte, K.; Van Dongen, W.; Hoes, I.; Lemiere, F.; Esmans, E. L.; Van Onckelen, H.; Van den Eeckhout, E.; Van Soest, R. E. J.; Hudson, A. J. Anal. Chem. 1997, 69, 3161.
Emmett, M. R.; White, F. M.; Hendrickson, C. L.; Shi, S. D.-H.; Marshall, A. G. J. Am. Soc. Mass Spectrom. 1998, 9, 333.
Vanhoutte, K.; Van Dongen, W.; Esmans, E. L. Rapid Commun. Mass Spectrom. 1998, 12, 15.
Hannis, J. C.; Muddiman, D. C. Rapid Commun. Mass Spectrom. 1998, 12, 443.
Geromanos, S.; Philip, J.; Freckleton, G.; Tempst, P. Rapid Commun. Mass Spectrom. 1998, 12, 551.