Abstract
The use of a quadrupole ion trap mass spectrometer (QITMS) for quantitative analysis of hydrogen and helium as well as of other permanent gases is demonstrated. Like commercial instruments, the customized QITMS uses mass selective instability; however, this instrument operates at a greater trapping frequency and without a buffer gas. Thus, a useable mass range from 2 to over 50 daltons (Da) is achieved. The performance of the ion trap is evaluated using part-per-million (ppm) concentrations of hydrogen, helium, oxygen, and argon mixed into a nitrogen gas stream, as outlined by the National Aeronautics and Space Administration (NASA), which is interested in monitoring for cryogenic fuel leaks within the Space Shuttle during launch preparations. When quantitating the four analytes, relative accuracy and precision were better than the NASA-required minimum of 10% error and 5% deviation, respectively. Limits of detection were below the NASA requirement of 25-ppm hydrogen and 100-ppm helium; those for oxygen and argon were within the same order of magnitude as the requirements. These results were achieved at a fast data recording rate, and demonstrate the utility of the QITMS as a real-time quantitative monitoring device for permanent gas analysis.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Paul, W.; Steinwedel, H. Apparatus for Separating Charged Particles of Different Specific Charges. U. S. Patent No. 2,939,952, 7 June, 1960.
Stafford, G. C.; Kelley, P. E.; Syka, J. E. P.; Reynolds, W. E.; Todd, J. F. J. Recent Improvements in and Analytical Applications of Advanced Ion Trap Technology. Int. J. Mass Spectrom. Ion Proc. 1984, 60, 85–98.
Stafford, G. C.; Kelley, P. E.; Stephens, D. R. Method of Mass Analyzing a Sample by Use of a Quadrupole Ion Trap. U. S. Patent No. 4,540,884, 10 September, 1985.
Ghosh, P. K. Ion Traps. Oxford University Press: New York, 1995; pp 232–235.
Dehmelt, H. G.; Jefferts, K. B. Alignment of the H. Phys. Rev. 1962, 125, 1318–1322.
Dehmelt, H. G.; Major, F. G. Orientation of (He4)+ Ions by Exchange Collisions with Cesium Atams. Phys. Rev. Lett. 1962, 8, 213–214.
Todd, J. F. J.; Lawson, G.; Bonner, R. F. Quadrupole Mass Spectrometry and Its Applications; Dawson, P. H., Ed., Elsevier: New York, 1976; pp 181–224 Chap VIII.
Alheit, R.; Henning, C.; Morgenstern, R.; Vedel, F.; Werth, G. Observation of Instabilities in a Paul Trap with Higher-Order Anharmonicities. Appl. Phys. B—Lasers and Optics 1995, 61, 277–283.
Alheit, R.; Kleineidam, S.; Vedel, F.; Vedel, M.; Werth, G. Higher Order Non-Linear Resonances in a Paul Trap. Int. J. Mass Spectrom. Ion Proc. 1996, 154, 155–169.
Alheit, R.; Chu, X. Z.; Hoefer, M.; Holzki, M.; Werth, G. Nonlinear Collective Oscillations of an Ion Cloud in a Paul Trap. Phys. Rev. A 1997, 56, 4023–4031.
Sheretov, E. P.; Rozhkov, O. W.; Kiryushin, D. W.; Malutin, A. E. Mass Selective Instability Mode without a Light Buffer Gas. Int. J. Mass Spectrom. 1999, 190/191, 103–111.
Griffin, T. P.; Naylor, G. R.; Haskell, W. D.; Breznik, G. S.; Mizell, C. A. A Fully Redundant On-Line Mass Spectrometric System for the Space Shuttle Used to Monitor Cryogenic Fuel Leaks. The Second Workshop on Harsh-Environment Mass Spectrometry; St. Petersburg, FL, March 18–21, 2001.
Griffin, T. P.; Naylor, G. R.; Hritz, R. J.; Barrett, A. Sample Delivery and Computer Control Systems for Detecting Leaks in the Main Engines of the Space Shuttle. Proceedings of the 45th ASMS Conference on Mass Spectrometry and Allied Topics; Palm Springs, CA, June, 1997; p 471.
Ottens, A. K.; Griffin, T. P.; Helms, W. R.; Yost, R. A. A Quadrupole Ion Trap Mass Spectrometer for Quantitative Analysis of Nitrogen-Purged Compartments within the Space Shuttle. Proceedings of the 49th ASMS Conference on Mass Spectrometry and Allied Topics; Chicago, IL, May, 2001; AO10267.
Ottens, A. K.; Griffin, T. P.; Helms, W. R.; Harrison, W. W. Quadrupole Ion Trap Mass Spectrometry for Space Shuttle Ground Support. The Third Workshop on Harsh-Environment Mass Spectrometry; Pasadena, CA, March 25–28, 2002.
Chutjian, A. Miniature Mass Spectrometer and Front-end Interfaces. The Third Workshop on Harsh-Environment Mass Spectrometry; Pasadena, CA, March 25–28, 2002.
Orient, O. J.; Chutjian, A. A Compact, High-Resolution Paul Ion Trap Mass Spectrometer with Electron-Impact Ionization. Rev. Sci. Instr. 2002, 75, 2157–2160.
Badman, E. R.; Cooks, R. G. Miniature Mass Analyzers. J. Mass Spectrom. 2000, 35, 659–671.
Hirohata, Y.; Mutoh, A.; Hino, T.; Yamashina, T.; Kikuchi, T.; Ohsako, N. Pump-down Characteristics of Outgassed Clean Stainless Steel Vacuum Chamber and Surface Analysis of the Chamber Wall. Vacuum 1996, 47, 727–731.
Harrison, A. G. Chemical Ionization Mass Spectrometry. CRC Press: Boca Raton, 1992.
Arkin, C. R.; Griffin, T. P.; Ottens, A. K.; Diaz, J. A.; Follistein, D. W.; Adams, F. W.; Helms, W. R. Evaluation of Small Mass Spectrometer Systems. J. Am. Soc. Mass Spectrom. to be published.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Ottens, A.K., Harrison, W.W., Griffin, T.P. et al. Real-time quantitative analysis of H2, He, O2, and Ar by quadrupole ion trap mass spectrometry. J. Am. Soc. Spectrom. 13, 1120–1128 (2002). https://doi.org/10.1016/S1044-0305(02)00431-2
Received:
Revised:
Accepted:
Issue Date: