Abstract
A variable flow “peak trapping” liquid chromatography (LC) interface has been developed for the coupling of nanoscale LC to electrospray ionization mass spectrometry (ESI-MS). The presented peak trapping LC interface allows for the extended analysis time of co-eluting compounds and has been employed for the identification of proteins via tandem mass spectrometry (MS/MS). The variable flow process can be controlled either manually or in a completely automated manner where the mass spectrometer status determines the status of the variable flow interface. When the mass spectrometer operates in MS survey mode, the interface is operated in a so-called “high-flow” mode. Alternatively, the interface is operated in a “low-flow” mode during MS/MS analysis. In the “high-flow” mode of the variable flow process the column flow rate is typically around 200 nL/min, whereas in the “low-flow” mode the column effluent is introduced into the source of the mass spectrometer at 25 nL/min. In addition to the flow reduction during MS/MS analysis, the gradient is paused to preserve the peptide separation on the analytical nanoscale LC column. The performance of the variable flow nanoscale LC/MS/MS interface is demonstrated by the automated analysis of standard peptide mixtures and protein digests utilizing variable flow, data-dependent scanning MS/MS techniques, and automated database searching.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Yates, J. R., 3rd; McCormack, A. L.; Schieltz, D.; Carmack, E.; Link, J. Protein Chem. A 1997, 16, 495–497.
Link, A. J.; Eng, J.; Schieltz, D. M.; Carmack, E.; Mize, G. J.; Morris, D. R.; Garvik, B. M.; Yates, J. R., III. Nat. Biotechnol. 1999, 17, 676–682.
Washburn, M. P.; Wolters, D.; Yates, J. R., 3rd. Nat. Biotechnol. 2001, 19, 242–247.
Moseley, M. A.; Deterding, L. J.; Tomer, K. B.; Jorgenson, J. W. Anal. Chem. 1991, 63, 1467–1473.
Hunt, D. F.; Alexander, J. E.; McCormack, A. L.; Martino, P. A.; Michel, H.; Shabanowitz, J.; Sherman, N.; Moseley, M. A.; Jorgenson, J. W.; Tomer, K. B. Tech. Protein Chem. 2 1991, 441–454 [Pap. Annu. Symp. Protein Soc.], 4th.
Morris, H. R.; Paxton, T.; Dell, A.; Langhorne, J.; Berg, M.; Bordoli, R. S.; Hoyes, J.; Bateman, R. H. Rapid Commun. Mass Spectrom. 1996, 10, 889–896.
Yates, J. R., III; Eng, J. K.; Clauser, K. R.; Burlingame, A. L. J. Am. Soc. Mass Spectrom. 1996, 7, 1089–1098.
Perkins, D. N.; Pappin, D. J. C.; Creasy, D. M.; Cottrell, J. S. Electrophoresis 1999, 20, 3551–3567.
Opiteck, G. J.; Jorgenson, J. W.; Anderegg, R. J. Anal. Chem. 1997, 69, 2283–2291.
Opiteck, G. J.; Lewis, K. C.; Jorgenson, J. W.; Anderegg, R. J. Anal. Chem. 1997, 69, 1518–1524.
Opiteck, G. J.; Jorgenson, J. W.; Moseley, M. A., III; Anderegg, R. J. J. Microcolumn Sep. 1998, 10, 365–375.
Opiteck, G. J.; Ramirez, S. M.; Jorgenson, J. W.; Moseley, M. A., III. Anal. Biochem. 1998, 258, 349–361.
Washburn, M. P.; Wolters, D.; Yates, J. R. Nat. Biotechnol. 2001, 19, 242–247.
Davis, M. T.; Stahl, D. C.; Lee, T. D. J. Am. Soc. Mass Spectrom. 1995, 6, 571–577.
Davis, M. T.; Lee, T. D. J. Am. Soc. Mass Spectrom. 1997, 8, 1059–1069.
Lee, T. D.; Davis, M. T.; Stahl, D. C.; Swiderek, K. M.; Esworthy, R. S.; Hefta, S. A. Nippon Iyo Masu Supekutoru Gakkai Koenshu 1996, 21, 17–32.
Martin, S. E.; Shabanowitz, J.; Hunt, D. F.; Marto, J. A. Anal. Chem. 2000, 72, 4266–4274.
Shabanowitz, J.; Settlage, R. E.; Marto, J. A.; Christian, R. E.; White, F. M.; Russo, P. S.; Martin, S. E.; Hunt, D. F. Mass Spectrom. Biol. Med. 2000, p 163–177.
Davis, M. T.; Stahl, D. C.; Hefta, S. A.; Lee, T. D. Anal. Chem. 1995, 67, 4549–4556.
Wilm, M. S.; Mann, M. Int. J. Mass Spectrom. Ion Processes 1994, 136, 167–180.
Wilm, M.; Mann, M. Anal. Chem. 1996, 68, 1–8.
Burkhart, W. In-Situ Proteolytic Digestions Performed on Proteins Bound to the Hewlett-Packard Hydrophobic Sequencing Cartridge. Academic Press: San Diego, CA, 1993, pp 399–406.
Koc, E. C.; Blackburn, K.; Burkhart, W.; Spremulli, L. L. Biochem. & Biophys. Research Commun. 1999, 266, 141–146.
Vissers, J. P. C.; Hulst, W. P.; Chervet, J. P.; Snijders, H. M. J.; Cramers, C. A. J. Chrom. B: Biomedical Applications 1996, 686, 119–128.
Geromanos, S.; Freckleton, G.; Tempst, P. Anal. Chem. 2000, 72, 777–790.
Moseley, M. A.; Blackburn, R. K.; Burkhart, W.; Vissers, J. P. C.; Bordoli, R. S. Increased Proteome Coverage using a Novel Peak Trapping Interface for Nanoscale Capillary LC/MS/MS Analysis of Complex Peptide Mixtures. Proceedings of the 48th ASMS Conference, Long Beach, CA, 2000.
Yamashita, M.; Fenn, J. B. J. Phys. Chem. 1984, 88, 4451.
Koc, E. C.; Burkhart, W.; Blackburn, K.; Moseley, A.; Koc, H.; Spremulli, L. L. J. Biol. Chem. 2000, 275, 32585–32591.
Koc, E. C.; Burkhart, W.; Blackburn, K.; Moyer, M. B.; Schlatzer, D. M.; Moseley, A.; Spremulli, L. L. J. Biol. Chem. 2001, 276, 43958–43969.
Koc, E. C.; Burkhart, W.; Blackburn, K.; Moseley, A.; Spremulli, L. L. J. Biol. Chem. 2001, 276, 19363–19374.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Vissers, J.P.C., Blackburn, R.K. & Moseley, M.A. A novel Interface for variable flow nanoscale LC/MS/MS for improved proteome coverage. J Am Soc Mass Spectrom 13, 760–771 (2002). https://doi.org/10.1016/S1044-0305(02)00418-X
Received:
Revised:
Accepted:
Issue Date: