Abstract
Use of optimized instrument parameters that result from statistical experimentation revealed that the sensitivity of atmospheric pressure chemical ionization (APCI) liquid chromatography-mass spectrometry (LC/MS) is greater than the sensitivity of an optimized Thermabeam™ LC/MS interface by about 3 orders of magnitude, when tested on aromatic compounds. APCI is one of the few LC/MS techniques in which the chromatogram is directly comparable with liquid chromatographs that use ultraviolet detection. The optimum instrument parameters for a Finnigan SSQ-7000 APCI LC/MS interface were found at low flow rates (e. g., 0. 1 mL/min), relatively low capillary heat (e. g., 225 °C), and high sheath-gas pressure (e. g., 60 lb/in2). The optimization was achieved by monitoring the responses of sensitivity, fragmentation, and cluster ion formation. The fine tuning for high sensitivity calls for a high percentage of water in the mobile phase. In contrast, a high percentage of organic content in the mobile phase is required to obtain abundant protonated molecular ions with respect to fragmentation and clustering. This is an important consideration for analyses of unknowns.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Van Berkel, G. J.; McLuckey, S. A.; Glish, G. L. Anal. Chem. 1991, 63, 2064.
Quirke, J. M. E.; Adams, C. L.; Van Berkel, G. J. Anal Chem. 1994, 66, 1302.
Colton, R.; Traeger, J. C.; Harrey, J. Org. Mass Spectrom. 1992, 27, 1030.
Hiroka, K.; Kudaka, I.; Fujimaki, S.; Shinohara, H. Rapid Commun. Mass Spectrom. 1992, 6, 254.
Wilson, S. R.; Wu, Y. J. Am. Soc. Mass Spectrom. 1993, 4, 596.
Van Berkel, G. J.; Asano, K. G. Anal. Chem. 1994, 66, 2096.
Van Berkel, G. J.; Asano, K. G.; McLuckey, S. A. J. Am. Soc. Mass Spectrom. 1994, 5, 689.
Van Berkel, G. J.; McLuckey, S. A.; Glish, G. L. Anal. Chem. 1992, 64, 1586.
Zook, D. R.; Bruins, A. P. Proceedings of the 42nd ASMS Conference on Mass Spectrometry and Allied Topics; Chicago, IL, 1994.
Blades, A. T.; Ikonomou, M. G.; Kebarle, P. Anal. Chem. 1991, 63, 2109.
Ikonomou, M. G.; Blades, A. T.; Kebarle, P. Anal. Chem. 1991, 63, 1989.
Fenn, J. B.; Mann, M.; Meng, C. K.; Wong, S. F. Mass Spectrom. Rev. 1990, 9, 37.
Fenn, J. B. J. Am. Soc. Mass Spectrom. 1993, 4, 524.
Tang, L.; Kebarle, P. Anal. Chem. 1991, 63, 2709.
Straub, R. F.; Voyksner, R. D. J. Am. Soc. Mass Spectrom. 1993, 4, 578.
Cole, R. B.; Harrata, A. K. J. Am. Soc. Mass Spectrom. 1993, 4, 546.
Kebarle, P.; Tang, L. Anal. Chem. 1993, 65, 972A.
Buckley, J. A.; French, J. B.; Reid, N. M. Can. Aeronaut. Space J. 1974, 20, 231.
The API Book; PE Sciex: Thornhill, ON, Canada, 1990.
Huertas, M. L.; Fontan, J. Atmospheric Environ. 1975, 9, 1018.
Box, G. E. P.; Hunter, W. G.; Hunter, S. J. Statistics for Experimenters; Wiley: New York, 1991.
Montgomery, D. C. Design and Analysis of Experiments; Wiley: New York, 1991.
Mark, H.; Workman, J., Jr. Spectroscopy 1994, 9, 26–27, 30–32; 10, 17–20.
Huang, S. K.; Glancy, S. B.; Stanbury, W. F. Rapid Commun. Mass Spectrom. 1993, 7, 722.
Huang, S. K.; Garza, N. J. Am. Soc. Mass Spectrom. 1995, 6, 507.
Martens, H.; Naes, T. Multivariate Calibration, Wiley: New York, 1989.
Wold, S. Chemometrics and Intelligent Lab. Syst. 1987, 2, 37.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Garcia, D.M., Huang, S.K. & Stansbury, W.F. Optimization of the atmospheric pressure chemical ionization liquid chromatography mass spectrometry interface. J Am Soc Mass Spectrom 7, 59–65 (1996). https://doi.org/10.1016/1044-0305(95)00620-6
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/1044-0305(95)00620-6