Abstract
Orthogonal acceleration is a method for gating ions from an ion beam into a time-of-flight (TOF) mass spectrometer. The technique involves a pulsed electric field to apply acceleration directed orthogonally to an ion beam. This approach is useful for coupling continuous ion sources to TOF mass analyzers. Most instruments of this type, which have been described in the literature, use steering electrodes after the orthogonal acceleration step. Those velocity components of ions originating from the ion beam velocity are minimized so that the deflected drift-trajectory is parallel to a transverse flight tube. In an alternative geometry the ion beam velocity is conserved and the drift-trajectory after the orthogonal acceleration step is spontaneous. The differences between the space-time focusing ability with spontaneous and deflected drift-trajectories are discussed and investigated. Trajectory calculations indicate that deflection fields placed after the orthogonal acceleration step distort the ion packet because, in this geometry, the flight-time to the detector is dependent on the position that the ions enter the steering optics. Increasing the duty-cycle efficiency by sampling longer sections of the continuous ion beam leads to a degradation of resolving power. Employing a spontaneous drift-trajectory after orthogonal acceleration provides the advantage that the arrival time spread for isobaric ions is, in principle, independent of the length of the ion beam sampled. The major implication of these findings is that simultaneously optimized sensitivity and resolving power may not be achievable with the deflected drift-trajectory instruments. The calculations are in agreement with results from the published data of a number of groups who have built instruments based on the orthogonal acceleration principle.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
Cotter, R. J. Anal. Chem. 1992, 64, 1027A-1039A.
Cotter, R. J. Biomed. Environ. Mass Spectrom. 1989, 18, 513–532.
Sanzone, G. Rev. Sci. Instrum. 1970, 41,741–742.
Grix, R.; Grüner, U.; Li, G.; Stroh, H.; Wollnik, H. Int. J. Mass Spectrom. Ion Prrrccsses 1989, 93, 323–330.
Dawson, J. H. J.; Guilhaus, M. Rapid Commun. Mass Specfrom. 1989, 3,155–159.
Coles, J.; Guilhaus, M. Trends Anal Chem. 1993, 12, 203–213.
Benson, S. W.; Grossman, J. J.; Elkin, H. S. U.S. Patent No. 2, 938, 116, May 24, 1960 (filed April 2, 1956).
O’Halloran, G. J.; Fluegge, R. A.; Betts, J. F.; Everett, W. L. Technical Documentary Report, No. ASD-TDR-62-644, Part I & II, prepared under Contract Nos. AF33 (616)-8374 and AF33(657)-11018 by The Bendix Corporation, Research Laboratories Division, Southfield, Michigan, 1964.
Gerhardt, Ph.; Löffler, S.; Homann, K. H. Proceedings of the 22nd Symposium (International) on Combustion; The University of Washington; Seattle, WA, August 14–19, 1988, pp. 395–401.
10. Chemushevich, I. V.; Dodonov, A. F.; Dodonova, T. F., Inventors; USSR Chem. Phys. Energy Problems Inst., Assignee. Soviet patent No. SU 1681340 A1, Mass Spectrometric Analysis According to Transit Time of Continuous Ion Beam—lnvolves Feeding Ions into Modulator in Direction Perpendicular to Axis of Drip Tube (filed February 25, 1987).
11. (a) Dodonov, A. F.; Chemushevich, I. V.; Laiko, V. V. Extended Abstract from the Proceedings of the 12th International Mass Spectrometry Conference; Amsterdam, The Netherlands, August 26–30, 1991; (b) see also Verentchikov, A.; Ens, W.; Standing, K. G. Paper MOA 10: 50 in Abstracts and Proccedings of the 41st Annual ASMS Conference on Mass Spectrometry and Allied Topics; San Francisco, CA, May 30–June 4, 1993.
12. Dodonov, A. F.; Chemushevich, I. V.; Dodonova, T. F.; Raznikov, V. V.; Talmze, V .L., Inventors; USSR Chem. Phys. Energy Problems Inst., Assignee. Soviet patent No. WO 91/03071 (PCT/SU89/00228), Method and Device for Continuous-Wave Ion Beam Time-of-Flight Mass Spectrometric Analysis (filed August 25, 1989).
Bergmann, T.: Martin, T. P.; Shaber, H. Rev. Sci. Instrum. 1990, 61, 2585–2591.
Sin, C. H.; Lee, E. D.; Lee, M. L. Anal. Chem 1991, 63, 2897–2900
15. Myers, D. P.; Hieftje, G. M. Proceedings of the 41st Annual ASMS Coference on Mass Spectromety and Allied Topics; San Francisco, CA, May 30-June 4, 1993, ThP 131.
Boyle, J. G.; Whitehouse, C. M. Alaal. Chem., 1992, 64, 2084–2089.
Clayton, E.; Bateman, R H. Rapid Comm. Mass Spectrom. 1992, 5, 719–720.
Pollard, J. E.; Lichtin, D. A.; Janson, S. W.; Cohen, R. B. Rev. Sci. Instrum. 1989, 60, 3171–3180.
Bergmann, T.; Martin, T. P.; Shaber, H. Rev. Sci. Instrum. 1989, 60, 347.
20. Application Note ITI 015B, Characterising and Troubleshooting High Speed Circuits, The LeCmy Corporation: Chestnut Ridge, NY, June 1993, p. 4.
21. Coles, J. N.; Guilhaus, M. J. Am. Soc. Mass Spectrom. 1994, 5, in press.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Guilhaus, M. Spontaneous and deflected drift-trajectories in orthogonal acceleration time-of-flight mass spectrometry. J Am Soc Mass Spectrom 5, 588–595 (1994). https://doi.org/10.1016/1044-0305(94)90009-4
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/1044-0305(94)90009-4