The effects of ion initial axial position on coherence of ion motion, induced ion cyclotron resonance (ICR) signal. and radial and z ejection have been evaluated by numerical simulation for a cubic Fourier transform-ion cyclotron resonance ion trap. For a given initial ion cyclotron phase and radius, ions of different initial z position are shown to be excited to significantly different ion cyclotron radii (and ultimately radially ejected at significantly different excitation amplitude-duration products). Ion initial z displacement from the trap midplane affects observed ICR signal magnitude in two ways: (1) for the same postexcitation cyclotron radius, an ion with larger initial z displacement induces a smaller ICR signal and (2) an ion with larger initial z displacement is excited to a smaller cyclotron radius. We also evaluate the induced ICR signal as a function of excitation amplitude-duration product for spatially uniform or Gaussian ion initial z distributions. In general, if the excitation waveform contains components at frequency, 2 ωz or (ω+ + 2 ωz, in which ωz is the axial C“trapping”) oscillation frequency, then ejection occurs axially. However, the resulting excitation amplitude-duration product for such axial ejection is significantly higher (factor of, ∼ 4) than that required for radial ejection (at ω+) for ions of small initial radius. The present results offer the first explanation of how, even if the ion is initially at rest on the z axis (i.e., zero excitation electric field amplitude on the z axis), z ejection (axial ejection) may nevertheless occur if the excitation waveform contains frequency components at ω+ + 2ωz and/or 2w z Namely, our simulations reveal that off-resonant excitation pushes ions away from the z axis, after which the ions are exposed to z excitation and eventual z ejection.
Article PDF
Similar content being viewed by others
References
Schweikhard.. L.; Marshall, A. G. J. Am. Soc. Mass Spectrom. 1993, 4, 433–452.
Comisarow, M. B. J. Chem. Phys. 1978, 69, 4097–4104.
Comisarow, M. B. In Ion Cyclotron Resonance Spectrometry II; Hartmann, H.; Wanczek, K,-P.J. Ed., Springer: Berlin, 1982; pp 484–513.
Limbach, P. A.; Grosshans, P. B.; Marshall, A. G. Anal. Chem. 1993, 65, 135–140.
Williams, E. R.; Henry, K. D.; McLafferty, F. W. J. Am. Chem. Soc. 1990, 112, 6157–6162.
Speir, J. P.; Gorman, G. S.; Pitsenberger, C. C.; Turner, C. A.; Wang, P. P.; Amster, I. J. Anal. Chem. 1993, 65. 1746–1752.
Guan, Z.; Hoftstadler, S. A.; Laude, D. A., Jr. Anal. Chem. 1993, 65, 1588–1593.
Guan, S., Am. Soc. Mass Spectrum. 19991, 2, 483–486.
Grosshans, P. B.; Chen, R.; Marshall, A. G. Int. J. Mass Spectrom. Ion Processes 1994, in press.
Brown, L. S.; Gabrielse, G. Rev. Mod. Phys. 1986, 58, 233–311.
Wang, M.; Marshall, A. G. Int. J. Mass Spectrom. Ion Processes 1990, 100, 323 -346.
Huang, S. K.; Rempel, D. L.; Gross, M. L. Int. J. Mass Spectrom. Ion Processes 1986, 72, 15–3l.
Rempel, D. L.; Huang, S. K.; Gross, M. L. Int. J. Mass Spectrom. Ion Processes 1986, 70, 163–184.
Allemann, M.; Kofel, P.; Kellerhals, H.; Wanczek, K.-P. Int. J. Mass Spectrom. Ion Processes 1987, 75, 47–54.
van der Hart, W. J.; van de Guchte, W. J. Int. J. Mass Spectrom. Ion Processes 1988, 82, 17–31.
van de Guchte, W. J.; van der Hart W. J. Int. J. Mass Spectrom. Ion Processes 1990, 95, 317–326.
Wang, M.; Marshall, A. G. Anal. Chem. 1990, 62, 515–520.
Fujiwara, M.; Yamauchi, T.; Miura, K.; Inoue, M. J. Amer. Soc. Mass Spectrom. 1992, 3, 847–852.
Mitchelt D. W.; Hearn, B. A.; DeLong, S. E. Int. J. Mass Spectrom. Ion Processes 1993, 125, 95–126.
Dunbar, R. C. Int. J. Mass Spectrom. Ion Processes 1984, 56, 1.
Grosshans, P. B.; Shields., P. J.; Marshall, A. G. J. Chem. Phys. 1991, 94, 5341–5352.
Xiang, X.; Guan, S.; Marshall, A. G. J. Am. Soc.Mass Spectrom. 1994, 8, 238–249.
Hanson, C. D, Castro, M. E.; Kerley, E. L.; Russell, D. H. Anal. Chem. 1990, 62, 520–526.
Caravatti, P.; Allernann, M. Org. Mass Spectrom. 1991, 26, 514–518.
Cuan, S.; Xiang, X.; Marshall, A. G. Int. T. Mass Spectrom. Ion Processes 1993, 124,. 53–67.
Schweikhard, L.; Guan, S.; Marshall, A. C. Int. J. Mass Spectrom. Ion Processes 1992, 120, 71–83.
Bollen, G.; Moore, R. B.; Savard, G.; Stolzenberg, H. Appl. Phys. 1990, 68, 4355–4374.
Savard, G.; Becker, S.; Bollen, G.; Kluge, H.-J.; Moore, R. B.; Schweikhard, L.; Stolzenberg, H.; Wiess, U. U. Phys. Lett. A 1991, 158, 247–252.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Xiang, X., Marshall, A.G. Simulated ion trajectory and induced signal in ion cyclotron resonance ion traps. Effect of ion initial axial position on ion coherence, induced signal, and radial or z ejection in a cubic trap. J. Am. Soc. Spectrom. 5, 807–813 (1994). https://doi.org/10.1016/1044-0305(94)87003-9
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/1044-0305(94)87003-9