Abstract
An inductively coupled plasma-time-of-flight mass spectrometer (ICP-TOFMS) has been constructed and evaluated for elemental analysis. The instrument produces analog spectra similar to those from quadrupole inductively coupled plasma mass spectrometers. The large abundance of Ar ions is deflected away from the microchannel plate detector to reduce detector dead time and space-charge complications. The ICP-TOFMS, operated in a linear (nonreflecting) mode, currently has a resolving power of 500 (full width at half maximum). Present ion optics employed in the instrument require a trade-off between signal-to-noise ratio and resolving power. In addition, mass-dependent kinetic energies in the supersonic beam created in the ICP mass spectrometer interface cause a mass bias in the right-angle TOFMS because the ions must be steered to the detector to compensate for their velocity in the supersonic beam direction. In the current design the sampling duty cycle is only approximately 3%, thereby limiting sensitivity. However, positive potentials applied to the right-angle extraction region can increase sensitivity by a factor of 2–4 by slowing down the ions that enter the extraction zone. The transmission efficiency of the TOFMS is approximately 20% and is limited by divergence of the ion packet in the drift tube.
Article PDF
Similar content being viewed by others
Avoid common mistakes on your manuscript.
References
O’Halloran, G. J.; Walker, L. W. Technical Document Report ASD TDR 62-644, Parts I and II, Nov. 1964. Prepared under Contract AF 33(657)-11018 by the Bendix Corporation, Research Laboratories Division, Southfield, MI.
Dodonov, A. E; Chernushevich, I. V.; Laiko, V. V. Book of Abstracts from the 12th International M4ss Spectrometry Conference; North-Holland: Amsterdam, 1991; p 153.
Coles, J.; Stutsel, M.; Guilhaus, M. Proceedings of the 40th ASMS Conference on Mass Spectrometry and Allied Topics; Washington, DC, 1992; p 10.
Boyle, J. G.; Whitehouse, C. M. Ana. Chem. 1992, 64, 2084–2089.
Sin, C. H.; Lee, E. D.; Lee, M. L. Anal. Chem. 1991, 63, 2897–2900.
Chien, B.M.; Michael, S. M.; Luhman, D.M. Anal. Chem. 1993, 65, 1916–1924.
Houk, R. S. Anal. Chem. 1986, 58, 97A-105A.
Myers, D. P.; Hieftjc, G. M. Microchem. J. 1993, 48, 259–277.
Kutscher, R.; Grix, R.; Li, G.; Wollnik, H. Int. J. Mass Spectrom. Ion Processes 1991, 103, 117–128.
Green, L. W.; Macdonald, R. G.; Sopchyshyn, F. C. Anal. Instrum. 1988, 17, 195–214.
Fassett, J. D.; Walker, R. J.; Travis, J. C.; Ruegg, F. C. Int. J. Mass Spectrom. Ion Processes 1987, 75, 111–126.
Simmons, D. S. Int. I. Mass Spectrom. Ion Processes 1984, 55, 15–30.
Wiley, W. C.; McClaren, I. H. Rev. Sci. lnstrum. 1955, 26, 1150–1157.
Fassel, V. A.; Bear, B. R. Spectrochim. Acta 1986, 41B, 1089–1113.
deHeer, W. A.; Milani, P. Reu. Sci. lnstrum. 1991,62, 670–677.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Myers, D.P., Li, G., Yang, P. et al. An inductively coupled plasma-time-of-flight mass spectrometer for elemental analysis. Part I: Optimization and characteristics. J Am Soc Mass Spectrom 5, 1008–1016 (1994). https://doi.org/10.1016/1044-0305(94)80019-7
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1016/1044-0305(94)80019-7