Remote mass spectrometric sampling of electrospray- and desorption electrospray-generated ions using an air ejector
Application Note
First Online:
Received:
Revised:
Accepted:
- 118 Downloads
- 25 Citations
Abstract
A commercial air ejector was coupled to an electrospray ionization linear ion trap mass spectrometer (LTQ) to transport remotely generated ions from both electrospray (ESI) and desorption electrospray ionization (DESI) sources. We demonstrate the remote analysis of a series of analyte ions that range from small molecules and polymers to polypeptides using the AE-LTQ interface. The details of the ESI-AE-LTQ and DESI-AE-LTQ experimental configurations are described and preliminary mass spectrometric data are presented.
Keywords
Melittin Inlet Pressure Desorption Electrospray Ionization PTFE Surface Venturi Effect
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.
Preview
Unable to display preview. Download preview PDF.
References
- 1.McEwen, C. N.; McKay, R. G.; Larsen, B. S. Analysis of Solids, Liquids, and Biological Tissues Using Solids Probe Introduction at Atmospheric Pressure on Commercial LC/MS Instruments. Anal. Chem. 2005, 77, 7826–7831.CrossRefGoogle Scholar
- 2.Cody, R. B.; Laramee, J. A.; Durst, H. D. Versatile New Ion Source for the Analysis of Materials in Open Air under Ambient Conditions. Anal. Chem. 2005, 77, 2297–2302.CrossRefGoogle Scholar
- 3.Takats, Z.; Wiseman, J. M.; Gologan, B.; Cooks, R. G. Mass Spectrometry Sampling under Ambient Conditions with Desorption Electrospray Ionization. Science. 2004, 306, 471–473.CrossRefGoogle Scholar
- 4.Coon, J. J.; Harrison, W. W. Laser Desorption-Atmospheric Pressure Chemical Ionization Mass Spectrometry for the Analysis of Peptides from Aqueous Solutions. Anal. Chem. 2002, 74, 5600–5605.CrossRefGoogle Scholar
- 5.Shiea, J.; Huang, M. Z.; HSu, H. J.; Lee, C. Y.; Yuan, C. H.; Beech, I.; Sunner, J. Electrospray-Assisted Laser Desorption/Ionization Mass Spectrometry for Direct Ambient Analysis of Solids. Rapid Commun. Mass Spectrom. 2005, 19, 3701–3704.CrossRefGoogle Scholar
- 6.Huang, M. Z.; Hsu, H. J.; Lee, L. Y.; Jeng, J. Y.; Shiea, L. T. Direct Protein Detection from Biological Media through Electrospray-Assisted Laser Desorption Ionization/Mass Spectrometry. J. Proteome Res. 2006, 5, 1107–1116.CrossRefGoogle Scholar
- 7.Sampson, J. S.; Hawkridge, A. M.; Muddiman, D. C. Generation and Detection of Multiply-Charged Peptides and Proteins by Matrix-Assisted Laser Desorption Electrospray Ionization (MALDESI) Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. J. Am. Soc. Mass Spectrom. 2006, 17, 1712–1716.CrossRefGoogle Scholar
- 8.Sampson, J. S.; Hawkridge, A. M.; Muddiman, D. C. Direct Characterization of Intact Polypeptides by Matrix Assisted Laser Desorption Electrospray Ionization (MALDESI) Quadrupole Fourier Transfrom Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun. Mass Spectrom. 2007, 21, 1150–1154.CrossRefGoogle Scholar
- 9.Badman, E. R.; Cooks, R. G. Special Feature: Perspective—Miniature Mass Analyzers. J. Mass Spectrom. 2000, 35, 659–671.CrossRefGoogle Scholar
- 10.Gao, L.; Song, Q. Y.; Patterson, G. E.; Cooks, R. G.; Ouyang, Z. Handheld Rectilinear Ion Trap Mass Spectrometer. Anal. Chem. 2006, 78, 5994–6002.CrossRefGoogle Scholar
- 11.Chaudhary, A.; van Amerom, F. H. W.; Short, R. T.; Bhansali, S. Fabrication and Testing of a Miniature Cylindrical Ion Trap Mass Spectrometer Constructed from Low Temperature Co-fired Ceramics. Int. J. Mass Spectrom. 2006, 251, 32–39.CrossRefGoogle Scholar
- 12.Mulligan, C. C.; Talaty, N.; Cooks, R. G. Desorption Electrospray Ionization with a Portable Mass Spectrometer: In Situ Analysis of Ambient Surfaces. Chem. Commun. 2006, 16, 1709–1711.CrossRefGoogle Scholar
- 13.Takats, Z.; Wiseman, J. M.; Cooks, R. G. Ambient Mass Spectrometry Using Desorption Electrospray Ionization (DESI): Instrumentation, Mechanisms and Applications in Forensics, Chemistry, and Biology. J. Mass Spectrom. 2005, 40, 1261–1275.CrossRefGoogle Scholar
- 14.Cotte-Rodriguez, I.; Cooks, R. G. Non-proximate Detection of Explosives and Chemical Warfare Agent Simulants by Desorption Electrospray ionization Mass Spectrometry. Chem. Commun. 2006, 28, 2968–2970.CrossRefGoogle Scholar
- 15.Takats, Z.; Nanita, S. C.; Cooks, R. G.; Schlosser, G.; Vekey, K. Amino Acid Clusters Formed by Sonic Spray Ionization. Anal. Chem. 2003, 75, 1514–1523.CrossRefGoogle Scholar
- 16.Bereman, M. S.; Muddiman, D. C. Detection of Attomole Amounts of Analyte by Desorption Electrospray Ionization Mass Spectrometry (DESI-MS) Determined Using Fluorescence Spectroscopy. J. Am. Soc. Mass Spectrom. 2007, 18, 1093–1096.CrossRefGoogle Scholar
- 17.Zhou, L.; Yue, B. F.; Dearden, D. V.; Lee, E. D.; Rockwood, A. L.; Lee, M. L. Incorporation of a Venturi Device in Electrospray Ionization. Anal. Chem. 2003, 75, 5978–5983.CrossRefGoogle Scholar
- 18.Hawkridge, A. M.; Zhou, L.; Lee, M. L.; Muddiman, D. C. Analytical Performance of a Venturi Device Integrated into an Electrospray Ionization Fourier Transform Ion Cyclotron Resonance Mass Spectrometer for Analysis of Nucleic Acids. Anal. Chem. 2004, 76, 4118–4122.CrossRefGoogle Scholar
- 19.Yang, P. X.; Cooks, R. G.; Ouyang, Z.; Hawkridge, A. M.; Muddiman, D. C. Gentle Protein Ionization Assisted by High-Velocity Gas Flow. Anal. Chem. 2005, 77, 6174–6183.CrossRefGoogle Scholar
Copyright information
© American Society for Mass Spectrometry 2007