Intercomparison study on accurate mass measurement of small molecules in mass spectrometry

  • Anthony W. T. Bristow
  • Kenneth S. Webb
Articles

Abstract

The results from an intercomparison of accurate mass measurement of a small molecule (molecular weight 475 Da) across a broad range of mass spectrometers are reported. The intercomparison was designed to evaluate the relative capabilities and the optimum methodology of the diverse range of mass spectrometers currently used to record accurate mass measurements. The data will be used as a basis for developing guidance on accurate mass measurement. The need for guidance has resulted from the continued growth in the use of accurate mass measurements for assignment of elemental formula in the chemical and biochemical industries. This has been fuelled by a number of factors and includes the rapid pace of instrument development, which has enabled accurate mass measurements to be made in a less costly, yet robust fashion. The data from the intercomparison will allow us to compare those protocols that produced excellent accuracy and precision with those that produced poorer accuracy and/or precision for each type of mass spectrometer. The key points for best practice will then be established from this comparison for each type of mass spectrometer and accurate mass measurement technique. A compound was sent to the participating laboratories (in the UK, Europe, and USA), the identity of which was not revealed. Each laboratory was asked to record a minimum of five repeat mass measurements of the molecular species using their local protocols and their preferred ionization technique or techniques. To the best of our knowledge there were no interfering (unresolved) ions that originated from the sample. A questionnaire was also completed with the experimental work. The information from the questionnaires was used to evaluate the protocols used to record the measurements. Forty-five laboratories have reported their results. To summarize the performance of mass spectrometers in the intercomparison, magnetic sector field mass spectrometers used in peak matching mode and FTMS reported the highest mean mass measurement accuracy (88 and 83%, respectively, achieved ≤1 ppm). Magnetic sector field mass spectrometers used in voltage scanning produced 60% of the mean mass measurements with accuracy ≤1 ppm. Magnetic sector field mass spectrometers used in magnet scanning modes, quadrupole-TOF and TOF instruments generally achieved mean mass measurement accuracy between 5 and 10 ppm. The two low resolution triple quadrupoles used in the inter-comparison produced mean mass measurement accuracy of <2 ppm. The precision of the data from each instrument and experiment type is an important consideration when evaluating their relative capabilities. Using both the precision and accuracy, it will be possible to define the uncertainty associated with the elemental formulae derived from accurate mass measurements. Therefore, a thorough statistical evaluation of the data is underway and will be presented in a subsequent publication.

Keywords

Mass Measurement Mass Accuracy Accurate Mass Measurement Elemental Formula Fourier Transform Mass Spectrometry 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.

References

  1. 1.
    Gross, M. L. Accurate Masses for Structure Confirmation. J. Am. Soc. Mass Spectrom. 1994, 5, 57.CrossRefGoogle Scholar
  2. 2.
    Price, P. C.; Gale, P. J.; Loo, J. A.; Heller, D. N.; Richardson, S. D. Duncan, M. W. ASMS Guidelines for Exact Mass Measurement and Elemental Composition—New Perspectives. Proceedings of the 50th Annual Conference on Mass Spectrometry and Allied Topics; Orlando FL, 2002.Google Scholar
  3. 3.
    Aston, F. W. Bakerian Lecture—A New Mass-Spectrograph and the Whole Number Rule. Roy. Soc. Proc. A. 1927, 115, 487–514.CrossRefGoogle Scholar
  4. 4.
    Beynon, J. H. High Resolution Mass Spectrometry of Organic Materials. Adv. Mass Spectrom. 1959, 328–354.Google Scholar
  5. 5.
    Quisenberry, K. S.; Scolman, T. T.; Nier, A. O. Atomic Masses of H1, D2, C12, and S32. Phys. Rev. 1956, 102(4), 1071–1075.CrossRefGoogle Scholar
  6. 6.
    Nier, A. O. In Improvements in Double-Focusing Mass Spectrometry. Nuclear Masses and Their Determination; Hintenberger, H., Ed.; Pergamon Press: London, New York, Paris, Los Angeles, 1957; pp 185–193.Google Scholar
  7. 7.
    Craig, R. D.; Green, B. N.; Waldron, J. D. Application of High Resolution Mass Spectrometry in Organic Chemistry. Chimia 1963, 17, 33–42.Google Scholar
  8. 8.
    Bieman, K. Utility of Exact Mass Measurement. Methods Enzymol 1990, 193, 295–305.CrossRefGoogle Scholar
  9. 9.
    Bieman, K. High-Resolution Mass Spectrometry of Natural Products. Pure Appl. Chem. 1964, 9(1), 95–118.CrossRefGoogle Scholar
  10. 10.
    Campbell, A. J.; Halliday, J. S. Mass Measurement from Low Intensity Ion Beams. Proceedings of the 13th Annual Conference on Mass Spectrometry and Allied Topics; St. Louis, MO, May 1965; pp 200–203.Google Scholar
  11. 11.
    Green, B. N.; Merren, T. O.; Murray J. G. Fast Scanning of Mass Spectra at High Resolution. Proceedings of the 13th Annual Conference on Mass Spectrometry and Allied Topics; St. Louis, MO, May 1965; pp 204–211.Google Scholar
  12. 12.
    Marshall, A. G. Scaling MS Plateaus with High-Resolution FT-ICRMS. Anal. Chem. 2002, 74(9), 253A-259A.CrossRefGoogle Scholar
  13. 13.
    Marshall, A. G.; Hendrickson, C. L.; Jackson, G. S. Fourier Transform Ion Cyclotron Resonance Mass Spectrometry: A Primer. Mass Spectrom Rev 1998, 17, 1–35.CrossRefGoogle Scholar
  14. 14.
    Amster, I. J. Fourier Transform Mass Spectrometry. J. Mass Spectrom. 1996, 31, 1325–1337.CrossRefGoogle Scholar
  15. 15.
    Eckers, C.; Wolff, J. C.; Haskins, N. J.; Sage, A. B.; Giles, K.; Bateman, R. Accurate Mass Liquid Chromatography/Mass Spectrometry on Orthogonal Acceleration Time-of-Flight Mass Analyzers Using Switching between Separate Sample and Reference Sprays. 1. Proof of Concept. Anal. Chem. 2000, 72, 3683–3688.CrossRefGoogle Scholar
  16. 16.
    Wolff, J. C. Eckers, C.; Sage, A. B.; Giles, K.; Bateman, R. Accurate Mass Liquid Chromatography/Mass Spectrometry on Quadrupole Orthogonal Acceleration Time-of-Flight Mass Analyzers Using Switching between Separate Sample and Reference Sprays. 2. Applications Using the Dual-Electrospray Ion Source. Anal. Chem. 2001, 73, 2605–2612.CrossRefGoogle Scholar
  17. 17.
    Blom, K. F. Estimating the Precision of Exact Mass Measurements on an Orthogonal Time-of-Flight Mass Spectrometer. Anal. Chem. 2001, 73, 715–719.CrossRefGoogle Scholar
  18. 18.
    Richards, D. Accurate Mass Quadrupole Time-of-Flight Mass Spectrometry for Veterinary Drug Metabolism. Proceedings of the 25th Annual Meeting of the British Mass Spectrometry Society; University of Southampton, UK, 2001; p 78; and personal communication, 2001.Google Scholar
  19. 19.
    Haddon, W. F.; Lukes, H, C. Elemental Composition Mass Spectrometry. Proceedings of the 22nd ASMS Conference on Mass Spectometry and Allied Topics; Philadelphia, PA, 1974; pp 436–439.Google Scholar
  20. 20.
    Haddon, W. F.; Harden, L. A.; Lieberman, A. E. Accurate Mass Measurement by Quadrupole Mass Spectrometry; Applications to LSIMS and Particle Beam-EI Spectra. Proceedings of the 38th ASMS Conference on Mass Spectometry and Allied Topics; Tucson, AZ, 1990; pp 122–123.Google Scholar
  21. 21.
    Tyler, A. N.; Clayton, E.; Green, B. N. Exact Mass Measurement of Polar Organic Molecules at Low Resolution Using Electrospray Ionization and a Quadrupole Mass Spectrometer. Anal. Chem. 1996, 68, 3561–3569.CrossRefGoogle Scholar
  22. 22.
    Stafford, G. J., Jr. Ion Trap Mass Spectrometry: A Personal Perspective. J. Am. Soc. Mass Spectrom. 2002, 13(6), 589–596.CrossRefGoogle Scholar
  23. 23.
    Sargent, M.; O’Connor, G. Feasibility Study: Mass Spectrometry Techniques for Accurate Molecular Weight Determinations of Large Molecule; 2002. Reference number LGC/VAM/2001/026. Available from the author upon request.Google Scholar
  24. 24.
    Sack, T. M.; Lapp, R. L.; Gross, M. L.; Kimble, B. J. A Method for the Statistical Evaluation of Accurate Mass Measurement Quality. Int. J. Mass Spectrom. Ion Processes. 1984, 61, 191–213.CrossRefGoogle Scholar

Copyright information

© American Society for Mass Spectrometry 2003

Authors and Affiliations

  • Anthony W. T. Bristow
    • 1
  • Kenneth S. Webb
    • 1
  1. 1.LGC LimitedTeddingtonUK

Personalised recommendations