A secondary ion microprobe ion trap mass spectrometer
- 423 Downloads
- 5 Citations
Abstract
An ion trap mass analyzer has been attached to an organic secondary ion microprobe. A pressure differential >100 can be maintained between the ion trap and microprobe. The well-focused secondary ion beam can transit a small (2 mm) diameter tube, but gas flow from ion trap to microprobe is impeded. This pressure differential allows the microprobe to retain imaging capability. Ion trap and microprobe data systems are integrated by taking advantage of the highly reproducible periodicity of the ion trap operating in resonant ejection mode and asynchronous signal and data acquisition afforded by commercially available interface cards. Secondary ion mass spectra and images obtained indicate an approximately 10-fold improvement in sensitivity, although preliminary evidence indicates low (<1%) trapping efficiency. Image data acquisition using the ion trap for mass analysis requires at least 10 times as much time compared to using a quadrupole mass filter because the mass-selected instability mode is used for mass analysis, i.e., mass resolution in the ion trap is not continuous as it is in the quadrupole.
Keywords
Quadrupole Mass Filter Chemical Noise Resonance Ejection Secondary Ionization Mass Spectrometry SpectrumReferences
- 1.Todd, P. J.; Schaaff, T. G.; Chaurand, P.; Caprioli, R. M. J. Mass Spectrom. 2001, 36, 355–369.CrossRefGoogle Scholar
- 2.Caprioli, R. M.; Farmer, T. B.; Gile, J. Anal. Chem. 1997, 69, 4751–4760.CrossRefGoogle Scholar
- 3.Todd, P. J.; McMahon, J. M.; Short, R. T.; McCandlish, C. A. Anal. Chem. 1997, 69, 529A-535A.Google Scholar
- 4.Todd, P. J.; Grimm, C. C.; Holland, W. M.; Markey, S. P. Anal. Chem. 1992, 64, 1871–1878.CrossRefGoogle Scholar
- 5.Burns, M. S. J. Microsc. 1982, 127, 237–258.Google Scholar
- 6.Chandra, S.; Morrison, G. H. Biol. Cell 1992, 74, 31–42.CrossRefGoogle Scholar
- 7.McMahon, J. M.; Short, R. T.; McCandlish, C. A.; Brenna, J. T.; Todd, P. J. Rapid Commun. Mass Spectrom. 1996, 10, 335–340.CrossRefGoogle Scholar
- 8.Benninghoven, A. Secondary Ion Mass Spectrometry Basic Concepts, Instrumental Aspects, Applications, and Trends. Wiley-Interscience: New York, 1987, 664–689.Google Scholar
- 9.Benninghoven, A. Surf. Sci. 1971, 28, 541.CrossRefGoogle Scholar
- 10.Dawson, P. H. Quadrupole Mass Spectrometry and Its Applications. Elsevier: Amsterdam, 1976, 105.Google Scholar
- 11.Short, R. T.; Grimm, C. C.; Todd, P. J. J. Am. Soc. Mass Spectrom. 1991, 2, 226–231.CrossRefGoogle Scholar
- 12.March, R. Quadrupole Storage Mass Spectrometry. John Wiley: New York, 1989, 369–70.Google Scholar
- 13.Ingram, J. C.; Groenewold, G. S.; Appelhans, A. D.; Dahl, D. A.; Delmore, J. E. Anal. Chem. 1996, 68, 1309–1316.CrossRefGoogle Scholar
- 14.McLuckey, S. A.; Glish, G. L.; Asano, K. G. Anal. Chim. Acta 1989, 225, 25–35.CrossRefGoogle Scholar
- 15.Qin, J.; Chait, B. T. Anal. Chem. 1996, 68, 2102–2107.CrossRefGoogle Scholar
- 16.Troendle, F. J.; Reddick, C. D.; Yost, R. A. J. Am. Soc. Mass Spectrom. 1999, 10, 1315–1321.CrossRefGoogle Scholar
- 17.Grimm, C. C.; Short, R. T.; Todd, P. J. J. Am. Soc. Mass Spectrom. 1991, 2, 362–371.CrossRefGoogle Scholar
- 18.Liebl, H. U. S. Patent 3,517,191 (1965).Google Scholar
- 19.Short, R. T.; McMahon, J. M.; Holland, W. M.; Todd, P. J. J. Am. Soc. Mass Spectrom. 1994, 5, 37–43.CrossRefGoogle Scholar
- 20.Bartmess, J. E.; Georgiadis, R. M. Vacuum 1983, 33, 149.CrossRefGoogle Scholar
- 21.Quarmby, S. T.; Yost, R. A. Int. J. Mass Spectrom. 1999, 190-191, 81–102.CrossRefGoogle Scholar