Skip to main content

Advertisement

Log in

A Randomized Comparative Study of Functional and Radiological Outcome of Tension Band Wiring for Patella Fractures Using SS Wire Versus Fiberwire

  • Original Article
  • Published:
Indian Journal of Orthopaedics Aims and scope Submit manuscript

Abstract

Background

Patellar fractures account for 1% of all skeletal injuries. Tension band wiring using SS wire has been the most commonly practiced procedure. Although this has shown good results, many patients experience hardware related problems like pain, irritation and prominence which necessitate it’s removal. Recent studies have highlighted braided sutures as a possible alternative to SS wire. The purpose of this study is to evaluate the functional and radiological outcomes and complications of TBW using SS wire versus FiberWire (a reinforced braided polyblend suture) for the treatment of displaced transverse patellar fractures.

Methods

A randomized comparative study was carried out at a tertiary care center from November 2019 to May 2021. 32 patients were randomized into two equal groups, one treated with TBW using FiberWire and the other with SS wire. Patients were followed up for a period of 20 weeks and evaluated for functional outcome using the Bostman scoring scale, radiological union, complications and hardware removal rates.

Results

The mean duration for radiological union was 12.85 weeks using FiberWire and 12.75 weeks using SS wire. The mean knee range of motion was 118.57° in the FiberWire group and 117.18° in the SS wire group. Functional scores in the FiberWire and SS wire groups were 24 (good) and 26 (good) respectively measured using the Bostman scoring scale at end of 20 weeks. Complications like hardware prominence, soft tissue irritation and hardware removal rates were significantly higher in the SS wire group with a p value of 0.023.

Conclusion

SS wire is biomechanically stronger than FiberWire when used for TBW. Both implants produce comparable results with respect to union rate, ROM and functional outcome, however, FiberWire causes fewer hardware complications like prominence and pain and hence alleviates the need for a second surgical procedure for implant removal. Thus, surgical treatment of transverse and inferior pole of patella fractures with TBW using FiberWire is a better alternative to SS wire considering early rehabilitation and lesser complication rates.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

References

  1. Bostrom, A. (1972). Fracture of the patella. A study of 422 patellar fractures. Acta Orthopaedica Scandinavica. Supplementum, 143, 1–80.

    CAS  PubMed  Google Scholar 

  2. Carpenter, J. E., Kasman, R. A., Patel, N., Lee, M. L., & Goldstein, S. A. (1997). Biomechanical evaluation of current patella fracture fixation techniques. Journal of Orthopaedic Trauma, 11, 351–356.

    Article  CAS  PubMed  Google Scholar 

  3. Carpenter, J. E., Kasman, R. A., Patel, N., Lee, M. L., & Goldstein, S. A. (1997). Biomechanical evaluation of current patella fracture fixation techniques. Journal of Orthopaedic Trauma, 11(5), 351–356.

    Article  CAS  PubMed  Google Scholar 

  4. Smith, S. T., Cramer, K. E., Karges, D. E., Watson, J. T., & Moed, B. R. (1997). Early complications in the operative treatment of patella fractures. Journal of Orthopaedic Trauma, 11, 183–187.

    Article  CAS  PubMed  Google Scholar 

  5. Patel, V. R., Parks, B. G., Wang, Y., Ebert, F. R., & Jinnah, R. H. (2000). Fixation of patella fractures with braided polyester suture: A biomechanical study. Injury, 31, 1–6.

    Article  CAS  PubMed  Google Scholar 

  6. Weber, M. J., Janecki, C. J., McLeod, P., Nelson, C. L., & Thompson, J. A. (1980). Efficacy of various forms of fixation of transverse fractures of the patella. Journal of Bone and Joint Surgery American, 62, 215–220.

    Article  CAS  Google Scholar 

  7. John, J., Wagner, W. W., & Kuiper, J. H. (2007). Tension-band wiring of transverse fractures of patella. The effect of site of wire twists and orientation of stainless steel wire loop: A biomechanical investigation. International Orthopaedics, 31, 703–707.

    Article  CAS  PubMed  Google Scholar 

  8. Hung, L. K., Chan, K. M., Chow, Y. N., & Leung, P. C. (1985). Fractured patella: Operative treatment using the tension band principle. Injury, 16, 343–347.

    Article  CAS  PubMed  Google Scholar 

  9. Kumar, G., Mereddy, P. K., Hakkalamani, S., & Donnachie, N. J. (2010). Implant removal following surgical stabilization of patella fracture. Orthopedics. https://doi.org/10.3928/01477447-20100329-14 PMID: 20506948.

    Article  PubMed  Google Scholar 

  10. Komatsu, F., Mori, R., & Uchio, Y. (2006). Optimum surgical suture material and methods to obtain high tensile strength at knots: Problems of conventional knots and the reinforcement effect of adhesive agent. Journal of Orthopaedic Science, 11(1), 70–74.

    Article  PubMed  Google Scholar 

  11. Wright, P. B., Budoff, J. E., Yeh, M. L., Kelm, Z. S., & Luo, Z. P. (2006). Strength of damaged suture: An in vitro study. Arthroscopy, 22(12), 1270-1275.e3. https://doi.org/10.1016/j.arthro.2006.08.019 PMID: 17157724.

    Article  PubMed  Google Scholar 

  12. McGreal, G., Reidy, D., Joy, A., et al. (1999). The biomechanical evaluation of polyester as a tension band for the internal fixation of patellar fractures. Journal of Medical Engineering & Technology, 23(2), 53–56.

    Article  CAS  Google Scholar 

  13. Whittle, A. P., & Wood, G. W., II. (2003). Fractures of the lower extremity. In S. T. Canale (Ed.), Campbell’s operative orthopaedics (10th ed., pp. 2796–2804). Mosby.

    Google Scholar 

  14. Egol, K., Howard, D., Monroy, A., Crespo, A., Tejwani, N., & Davidovitch, R. (2014). Patella fracture fixation with suture and wire: You reap what you sew. Iowa Orthopaedic Journal, 34, 63–67. PMID: 25328461; PMCID: PMC4127725.

    PubMed  PubMed Central  Google Scholar 

  15. Wright, P., Kosmopoulos, V., Coté, R., Tayag, T., & Nana, A. (2009). FiberWire® is superior in strength to stainless steel wire for tension band fixation of transverse patellar fractures. Injury, 40(11), 1200–1203.

    Article  CAS  PubMed  Google Scholar 

  16. Camarda, L., La Gattuta, A., Butera, M., Siragusa, F., & D’Arienzo, M. (2015). FiberWire tension band for patellar fractures. Journal of Orthopaedics and Traumatology, 17(1), 75–80.

    Article  PubMed  PubMed Central  Google Scholar 

  17. Chatakondu, S. C., Abhaykumar, S., & Elliott, D. S. (1998). The use of non-absorbable suture in the fixation of patellar fractures: A preliminary report. Injury, 29(1), 23–27. https://doi.org/10.1016/s0020-1383(97)00114-9 PMID: 9659476.

    Article  CAS  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. T. Noothan.

Ethics declarations

Conflict of Interest

The authors have no conflicts of interest to declare. All co-authors have seen and agree with the contents of the manuscript and there is no financial interest to report. We certify that the submission is original work and is not under review at any other publication.

Ethical approval

Institutional ethical clearance was obtained before the  commencement of the study. 

Informed consent

Informed consent was obtained from all patients, those patients who refused to give consent for the procedure were excluded from the study.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Noothan, P.T., Somashekara, S.A., Sunkappa, S.R. et al. A Randomized Comparative Study of Functional and Radiological Outcome of Tension Band Wiring for Patella Fractures Using SS Wire Versus Fiberwire. JOIO 57, 876–883 (2023). https://doi.org/10.1007/s43465-022-00778-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s43465-022-00778-2

Keywords

Navigation