Abstract
Purpose
The earlier the detection and diagnosis of congenital heart diseases (CHD), the greater the clinical benefit; however, early fetal cardiac examination can be a challenge.
The aim of our study is to demonstrate that the fetal cardiac examination at 13+0–13+6 weeks can be as adequately assessed as the examination performed at 16 weeks in patients with low and high body mass index (BMI).
Methods
The study was a prospective observational cohort study. One hundred pregnant women at low risk of congenital heart anomalies were divided into two groups: 49 women with low BMI (<25) and 51 women with high BMI (≥ 25).
A complete fetal cardiac scan was performed on each patient at 13+0–13+6 weeks, via the transvaginal and transabdominal approaches, and at 16 weeks by the transabdominal approach.
Results
The examination at 13+0–13+6 weeks was adequately assessed in at least one of the two routes in 97 patients, as opposed to 87 patients at 16 weeks. A significantly higher adequate assessment rate was obtained at 13+0–13+6 weeks than at 16 weeks (p=0.017).
The transvaginal approach showed the best resolution of the three examinations in 42% of women with BMI ≥35. No CHD were overlooked.
Conclusions
Early fetal echocardiography is feasible and accurate at 13+0–13+6 weeks. Within patients with high BMI, early fetal echocardiography may be performed two weeks in advance, since it allows visualization of the fetal heart through the transvaginal route with a higher resolution in a large number of women, which is not feasible at 16 weeks.
Similar content being viewed by others
Data Availability
The anonymized data that support the findings of this study are available from the corresponding author upon reasonable request.
References
Khalil A, Nicolaides KH. Fetal heart defects: potential and pitfalls of first-trimester detection. Semin Fetal Neonatal Med. 2013;18(5):251–60. https://doi.org/10.1016/j.siny.2013.05.004.
Sarkola T, Ojala TH, Ulander VM, Jaeggi E, Pitkänen OM. Screening for congenital heart defects by transabdominal ultrasound-role of early gestational screening and importance of operator training. Acta Obstet Gynecol Scand. 2015;94(3):231–5. https://doi.org/10.1111/aogs.12572.
Abuhamad A, Chaoui R. A practical guide to fetal echocardiography: normal and abnormal heart. 3rd ed. Philadelphia: Wolkers Kluwer Health/Lippincott Williams And Wilkins; 2015.
Salomon LJ, Alfirevic Z, Bilardo CM, Chalouhi GE, Ghi T, Kagan KO, et al. ISUOG practice guidelines: performance of first-trimester fetal ultrasound scan. Ultrasound Obstet Gynecol. 2013;41(1):102–13. https://doi.org/10.1002/uog.12342 Erratum in: Ultrasound Obstet Gynecol. 2013 Feb;41(2):240.
Pooh RK, Maeda K, Kurjak A, Sen C, Ebrashy A, Adra A, et al. 3D/4D sonography - any safety problem. J Perinat Med. 2016;44(2):125–9. https://doi.org/10.1515/jpm-2015-0225.
Gembruch U, Knopfie G, Chatterjee M, Bald R, Hansmann M. First trimester diagnosis of fetal congenital heart disease by transvaginal two-dimensional and Doppler echocardiography. Obstet Gynecol. 1990;75:496–8.
Bronshtein M, Zimmer EZ, Milo S, Ho SY, Lorber A, Gerlis LM. Fetal cardiac abnormalities detected by transvaginal sonography at 12–16 weeks’ gestation. Obstet Gynecol. 1991;78:374–8.
Yagel S, Cohen SM, Messing M. First and early second trimester fetal heart screening. Curr Opin Obstet Gynecol. 2007;19(2):183–90. https://doi.org/10.1097/GCO.0b013e3280895de6.
DeVore GR. First trimester fetal echocardiography: is the future now? Ultrasound Obstet Gynecol. 2002;20:6–8. https://doi.org/10.1046/j.1469-0705.2002.00764.x.
Hutchinson D, McBrien A, Howley L, Yamamoto Y, Sekar P, Motan T, et al. First-trimester fetal echocardiography: identification of cardiac structures for screening from 6 to 13 weeks’ gestational age. J Am Soc Echocardiogr. 2017;30(8):763–72. https://doi.org/10.1016/j.echo.2017.03.017.
Tudorache S, Cara M, Iliescu DG, Novac L, Cernea N. First trimester two- and four-dimensional cardiac scan: intra- and interobserver agreement, comparison between methods and benefits of color Doppler technique. Ultrasound Obstet Gynecol. 2013;42(6):659–68. https://doi.org/10.1002/uog.12459.
Lombardi CM, Bellotti M, Fesslova V, Cappellini A. Fetal echocardiography at the time of the nuchal translucency scan. Ultrasound Obstet Gynecol. 2007;29:249–57. https://doi.org/10.1002/uog.3948.
Huggon IC, Ghi T, Cook AC, Zosmer N, Allan LD, Nicolaides KH. Fetal cardiac abnormalities identified prior to 14 weeks’ gestation. Ultrasound Obstet Gynecol. 2002;20:22–9. https://doi.org/10.1046/j.1469-0705.2002.00733.x.
World Health Organization (WHO). Obesity and overweight. Fact sheet n° 311. 2016.
Hendler I, Blackwell SC, Bujold E, Treadwell MC, Mittal P, Sokol RJ, et al. Suboptimal second-trimester ultrasonographic visualization of the fetal heart in obese women should we repeat the examination? J Ultrasound Med. 2005;24:1205–9. https://doi.org/10.7863/jum.2005.24.9.1205.
McBrien A, Hornberger LK. Early fetal echocardiography. Birth Defects Res. 2018. https://doi.org/10.1002/bdr2.1414.
Mills JL, Troendle J, Conley MR, Carter T, Druschel CM. Maternal obesity and congenital heart defects: a population-based study. Am J Clin Nutr. 2010;91:1543–9. https://doi.org/10.3945/ajcn.2009.28865.
Bertagna F, Rakza T, Vaksmann G, Ramdane-Sebbane N, Devisme L, Storme L, et al. Transposition of the great arteries: factors influencing prenatal diagnosis. Prenat Diagn. 2014;34:534–7. https://doi.org/10.1002/pd.4343.
Romary L, Sinkovskaya E, Ali S, Cunningham TD, Marwitz S, Heeze A, et al. The role of early gestation ultrasound in the assessment of fetal anatomy in maternal obesity. J Ultrasound Med. 2017;36:1161–8. https://doi.org/10.7863/ultra.16.06083.
Majeed A, Abuhamad A, Romary L, Sinkovskaya E. Can ultrasound in early gestation improve visualization of fetal cardiac structures in obese pregnant women? J Ultrasound Med. 2019;38(8):2057–63. https://doi.org/10.1002/jum.14895.
Author information
Authors and Affiliations
Contributions
Study conception and design: R García Delgado, JA García. Material preparation: R García Rodríguez., M Medina. Sonographer: R García Delgado. Data collection and analysis were performed by R García Delgado, R García Rodríguez, I Ortega, M de Luis, and J Segura. Statistical analysis of the data: JM González. The first draft of the manuscript was written by R García Delgado and all authors commented on previous versions of the manuscript. All authors read and approved the final manuscript.
Corresponding author
Ethics declarations
Ethics Approval and Consent to Participate
This study was performed in line with the principles of the Declaration of Helsinki. The study was approved by the Ethics and Research Committee of the Complejo Hospitalario Universitario Insular Materno Infantil. (CEIC-CHUIMI-2015/819). Informed consent was obtained from all individual participants included in the study.
Consent for Publication
Patients signed informed consent regarding publishing their data and ultrasound images.
Competing Interests
The authors declare no competing interests.
Additional information
Publisher’s Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
García Delgado, R., García Rodríguez, R., Ortega Cárdenes, I. et al. Feasibility and Accuracy of Early Fetal Echocardiography Performed at 13+0–13+6 Weeks in a Population with Low and High Body Mass Index: a Prospective Study. Reprod. Sci. 28, 2270–2277 (2021). https://doi.org/10.1007/s43032-021-00477-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s43032-021-00477-7