1 Introduction

One of the main environmental challenges of the twenty-first century is the pollution of the lakes, rivers, streams and oceans. Among all the contaminants detected in water, a large concern has emerged about the occurrence of micropollutants of diverse chemical natures. Micropollutants are contaminants, which are present at trace levels ranging from ng L−1 up to hundreds of µg L−1 [1, 2]. This category of pollutants notably includes pharmaceuticals, endocrine disruptors, hormones, personal care products and perfluorinated compounds. They can have a significant effect on water quality, living organisms and ecosystems. They can produce adverse effects even at very low concentrations [2,3,4]. The processes used in the conventional wastewater treatment plants (WWTPs) are not able to remove efficiently a great number of these biorecalcitrant contaminants [4, 5]. Several reasons can explain this aspect. First, the micropollutants are biorecalcitrants to the biological degradation which might occur during the biological treatments. Second, the micropollutants are generally polar. Consequently, they are not adsorbed onto the sludge and they cannot be removed by sedimentation. For the same reason, they cannot be eliminated by the tertiary treatments (sand filtration, lagooning process). Third, the diversity of pollutants (macro and micro) with different physico-chemical properties entering inside the conventional WWTPs plays also a role. The operating conditions to remove all these pollutants are different while the reactors design and the operating conditions (flow-rate, etc.) inside the conventional WWTPs are mainly made to remove the macropollutants [6]. Consequently, micropollutants concentrations from ng L−1 to µg L−1 are commonly encountered at the outlet of the WWTPs and find their ways into rivers [7,8,9]. Other routes of contaminations exist. The leaching from farmlands and agricultural runoff, the infiltration inside fractured bedrocks are some examples.

The development of new kinds of technologies capable of eliminating a wide spectrum of micropollutants of diverse chemical natures becomes necessary. Physicochemical processes (adsorption, membrane technology) appear as auspicious methods [10,11,12,13] but they produce a transfer of pollution from the water to another materials, which need to be retreated in an additional step. Advanced oxidation processes (AOPs) seem to be the most promising technologies because they are able, under certain conditions, to totally mineralize the pollutants present in the water [14, 15]. AOPs are based on the production of very strong oxidizing agents, the hydroxyl radicals, that are capable of degrading biorecalcitrant compounds [14, 15]. AOPs are particularly adapted to treat water at low pollutant concentrations and low or moderate flow-rates [15]. In addition, the kinetic of photodegradation by photocatalysis and photo-Fenton is quite slow. As an example, it can take several hours to reach the complete mineralization of water containing pollutants at concentration of mg/L. As a consequence, they are more efficient to remove in a sufficient short amount of time the micropollutants with concentrations of ng/L and µg/L. Heterogeneous photocatalysis and photo-Fenton are one of the most efficient AOPs for the removal of organic compounds and micropollutants [16, 17].

Several studies demonstrated that photocatalysis and photo-Fenton processes are efficient to degrade a wide range of micropollutants under ideal laboratory solution conditions with contaminant concentrations ranging from µg L−1 to mg L−1 [18,19,20,21,22,23]. However, these large concentrations of micropollutants are not representative of those encountered in real surface waters (lakes, rivers). Recently, the removal of micropollutants has been studied using synthetic and real waters (WWTP effluents or water from rivers) spiked with solutions of model micropollutants [20,21,22,23]. Only very few studies worked with micropollutants, at low concentrations in the range of ng L−1, from real water. The two processes appear efficient to remove several micropollutants, in the range of concentrations from 1 to 500 ng L−1, from real waters (outlet of drinking water treatment plant, effluent from a WWTP, real municipal effluent) [24,25,26,27].

However, the most appropriate AOP to remove the micropollutants is still under discussions. It appears that the comparison between the degradation performances of the AOPs concerns mainly heterogeneous photocatalysis and homogeneous photo-Fenton [28,29,30,31,32]. The general trend is that homogeneous photo-Fenton leads to better removal efficiency than that of TiO2 photocatalysis [28,29,30,31]. The comparison of the efficacy of heterogeneous photocatalysis and heterogeneous photo-Fenton is barely reported in the scientific literature. In addition, to our knowledge, no specific study has been conducted with the aim to compare the heterogeneous photocatalysis and heterogeneous photo-Fenton removal of various microcontaminants at concentrations of ng L−1 from a real river water.

In this study, for the first time, the efficiency of classical TiO2 UV photocatalysis and photo-Fenton process with iron-impregnated faujasite is compared and tested towards the removal of 21 micropollutants from a real river. River water downstream a WWTP has been selected because it represents a real water system with different micropollutants at low concentrations (from few ng L−1 to hundreds ng L−1) and in real conditions related to matrix effect and other water contaminants. The contaminants studied are composed of pharmaceuticals, personal care products, endocrine disruptors and perfluorinated compounds. Two sampling campaigns were carried out at different periods of the year in order to modulate the microcontaminants concentration in addition to the matrix composition.

2 Materials and methods

2.1 Water sampling

Water samples were collected from the Meurthe River, close to the city of Nancy in the northeast of France. The samples were taken from a specific site called Moulin Noir. The site was situated downstream the WWTP. The exact position of the sampling site is given in Fig. S1 of the Supporting Information. The latitude and longitude coordinates were equal to 48°44.605′N and 6°10.865′E, respectively. Two sampling campaigns were conducted on October 14th 2016 and March 17th 2017. On October 14th 2016, the weather was dry but cloudy. The air temperature was around 8 °C. On March 17th 2017, the sampling took place under a cloudy sky with atmospheric temperature of 10 °C. The volumetric flow-rates in Moulin Noir on October 14th 2016 and March 17th 2017 amounted to 9.28 and 35.40 m3/s, respectively. The samples were collected from the middle of a bridge crossing the river to ensure the good mixing of the water. The water was collected using brown glass bottle (volume of 1 L) surrounded by iron cover, to avoid its breakage, using a thick long ribbon that was dropped from the bridge into the river. The collected waters were filtrated by two processes. First, funnel and filter paper were employed to remove the bulk materials. Then, the water was filtrated using a glass-fiber filter of 1.2 μm porosity followed by a cellulose acetate filter with a porosity of 0.45 μm. Then, the sampled waters were kept in dark glass bottles at a temperature of 4 °C.

To estimate the nature and amount of some of the water components, and particularly the macropollutants present in the water, various analyses were performed. Non-purgeable organic carbon (NPOC), total nitrogen (TN) and inorganic carbon (IC) were evaluated using a TOC-VCSH analyzer (Shimadzu). The UV–visible absorbance spectra were obtained with a spectrophotometer (Cary 5G UV–Vis-NIR). The fluorescence spectra were recorded with a F-2500 fluorescence spectrophotometer. The apparatus operated in synchronous fluorescence mode under excitation wavelengths (λex) ranging from 230 to 600 nm with Δλ (λem − λex) = 50 nm. λem denoted the fluorescence emission wavelength. The concentrations of different ions (Cl, CO32−, SO42−, NO3) were measured by ICS-3000 Reagent-Free™ Ion Chromatography (RFIC™) using hydroxide eluents with a flow-rate of 1 mL/min and AS18 (4 × 250 mm) column.

2.2 Adsorption, photolysis, photocatalysis and photo-Fenton experiments

For photocatalysis experiments, the photocatalyst consisted of commercial Degussa P25 TiO2 particles constituted of 75% anatase and 25% rutile. A previously developed iron-impregnated faujasite was used to degrade the microcontaminants by heterogeneous photo-Fenton process. The catalyst was prepared by wet impregnation of iron (III) nitrate nonahydrate deposited onto the faujasite [33]. The faujasite contained 20 wt% of iron. The Table 1 summarizes some of the properties of the two catalysts. In the previous paper [33] we developed the synthesis of the iron-impregnated faujasite. In addition, the photo-Fenton process was optimized in terms of pH, H2O2 content, iron content deposited onto the faujasite, and light intensity. This optimization was conducted using macropollutant as well as micropollutants sampled from the Meurthe River. The sampling period and also the sampling position were different from those utilized here. However, in the previous study, the number of micropollutants with initial concentrations lower than the limit of quantification of the LC–MS/MS was relatively high. For this reason, in the present work, the water was sampled in a different position (in the site called Moulin Noir) and also at different periods of the year to work with larger amounts of different micropollutants at various concentrations. In addition, in the present study, the photo-Fenton removal experiments were directly conducted under the optimized conditions.

Table 1 Comparison of the surface properties of the iron-impregnated faujasite and TiO2

The experiments were carried out, at room temperature, in glass crystallizers. The reaction media was illuminated with a mercury lamp (low-pressure mercury arc, 18 W, wavelength of 254 ± 12 nm) placed vertically 3.5 cm far from the top of the crystallizer. The total fluence reaching the reaction media amounted to 10−6 Einstein L−1 s−1. For each photodegradation test, 600 mL of water sample was utilized because a minimum volume of 500 mL was needed to perform a reliable quantification of all the micropollutants. In order to conduct the experiments with our conventional photocatalytic experimental assembly currently used in our previous works [34, 35], the volume of water was divided into 3 crystallizers of 200 mL each. An amount of 0.2 g of catalyst, i.e. TiO2 or iron-impregnated faujasite, was dispersed into 200 mL of the water sampled from the river for each reactor. Only for the photo-Fenton degradation tests, the experiments were performed in the presence of 0.007 mol/L (0.238 g/L) of H2O2. This amount of H2O2 was chosen based on the optimization and effect of several criteria studied before [33]. It corresponded to a ratio [H2O2]/[Fe] = 0.4 which ensured a total reaction of the used H2O2, avoiding its presence at the end of the reaction. For each experiment, the three reactors worked in parallel. The suspensions containing the micropollutants were kept under magnetic stirring in the dark during 2 h. This step appeared necessary to ensure the adsorption equilibrium [36] and evaluate the adsorption capacity of the catalysts towards the micropollutants. After completion of this step, the lamp was switched on. The degradation tests were conducted during 30 min or 6 h under UV irradiation and magnetic stirring. No intermediate sampling was performed during the experiments. At the end of the process, the whole treated waters from the three reactors were recovered and mixed together. The treated water was centrifuged for 25 min at 4000 rpm in order to separate the particles from the solution.

The waters used for the photocatalysis and photo-Fenton degradation tests were the same. They were collected on October 14th 2016 and March 17th 2017. The water samples were treated by photo-Fenton the same day or, at least, 24 h after the photocatalytic reactions. The only difference between the two experiments was the nature of the catalyst (TiO2 vs iron-impregnated faujasite) and the presence of H2O2 during the photo-Fenton process. Note also that the photolysis tests were conducted in the absence of catalyst and H2O2. Every experiment was repeated three times, and the data presented below are the averages of the repeated results.

2.3 Micropollutants detection and quantification

Before the quantification of the micropollutants by LC–MS/MS, a concentration step by solid-phase extraction (SPE) was necessary. The solution was adjusted to pH 4 by adding concentrated sulfuric acid. 550 mL of water sample were concentrated 1100 times by SPE using an Autotrace SPE Workstation (Thermo Fisher Scientific). The SPE phase (Oasis HLB 200 mg/6 mL, Waters) was successively conditioned with methanol, followed by ultra-pure water at pH 4. After the sample loading, the cartridge was successively cleaned with a 95/5 (v/v) water/methanol mixture, dried under a stream of nitrogen, and finally eluted with 10 mL of methanol. The extract was evaporated under vacuum at 50 °C to the drop and recovered in 500 µL of water/methanol 90/10 (v/v). All the eluents were of ultra-pure grade. The final extract was analyzed by liquid chromatography (1260 Series, Agilent) coupled to triple-quadrupole mass spectrometry (QTRAP 4500, AB Sciex). The chromatographic separation was conducted on a Zorbax Eclipse Plus C18 column (150 × 2.1 mm ID, 3.5 µm particle size, Agilent). The flow-rate of the mobile phase was fixed to 0.25 mL/min while the temperature of the oven was maintained at 40 °C. The detailed nature of the mobile phases and the eluent programs are given in the Supporting Information (Table S1 of the Supporting Information). The mass spectrometer was operated in positive or negative electrospray mode depending on the target molecules (Table S2 of the Supporting Information). Two transitions were recorded in Multiple Reaction Monitoring mode for quantification and confirmation of each target compound. Quantitative results were provided thanks to internal calibrations.

We focused our analysis on twenty-one micropollutants. They were selected based on several factors including the usage (pharmaceuticals, hormones, and industrial compounds), the health concern, the occurrence in the municipal wastewater and water systems, and the physicochemical properties. These contaminants belonged to four different families, which are pharmaceuticals, personal care products, endocrine disruptors and perfluorinated compounds. The Table S2 in the Supporting Information provides more information about the selected contaminants.

We are aware that by-products can be produced during the water treatment and, thus, participate to the overall toxicity of the treated samples. However, the LC–MS/MS analysis described in this study was performed in Multiple Reaction Monitoring (MRM) mode, to ensure the best sensitivity and reliability of the measurements. As a matter of fact, this method offered very good performances, but was specific to the targeted analytes. So, the potential degradation products cannot be detected. The detection of by-products, even if fully relevant, would have required a “full scan” LC–MS method to allow the detection of unknown compounds, but with much higher quantification limits. Considering our aims in this study, we choose to give the priority to the sensitivity and ensure the detection of the target analytes at environmental concentration levels.

3 Results and discussion

3.1 Characterization of the matrix

Preliminary experiments were undertaken to evaluate the amount and the nature of some of the water components, and particularly, the macropollutants present in the water. They are representative of the matrix containing the targeted microcontaminants. The results of the analyses are summarized in Table 2.

Table 2 Comparison of the physicochemical characteristics of the two waters

Dissolved organic matter (DOM), dissolved organic carbon (DOC), and biochemical oxygen demand (BOD) in the river water are studied through fluorescence spectrophotometry (Fig. S2a of the Supporting Information). For the two water samples, the presence of two main peaks is observed: tryptophan-like fluorescence (λex = 288 nm, λem = 338 nm) related to protein-like substances and fulvic acids fluorescence (λex = 355 nm, λem = 405 nm). The position of the two peaks is the same for the two waters indicating similar DOM nature [37]. Tryptophan-like fluorescence can be used as an indicator of domestic pollution concentration [38]. Fulvic acids fluorescence intensity is found to be very close between the waters collected in October (152 a.u.) and March (117 a.u.), which reflects a similar fulvic acid component content. This result is consistent with the NPOC values (or DOC) that show no significant difference between the two waters.

The UV–visible spectroscopic analysis gives an idea about the nitrate and nitrite species present in the river water from the absorbance peak at 190 nm (A190, Fig. S2b of the Supporting Information). Similar intensities are recorded for this peak for the two waters indicating similar inorganic nitrate content. This result is confirmed by the slight variation in the amount of nitrate species detected in the two samples. Moreover, the UV absorbance at 254 nm (A254) has been found by most authors to be correlated to the DOM, the chemical oxygen demand (COD), and the TOC. Similar A254 (A254 = 0.07) are measured for the two samples. This is another indication for the close content nature of organic matter of the water matrices of the two waters. Specific UV absorbance (SUVA = A254 × 100/DOC) gives an indication of the content of aromatic and unsaturated organic compounds and reflects the DOM type. The SUVA values for the two waters (2.5 L mg−1 in October and 2.2 L mg−1 in March) are close indicating similar aromatic organic carbon content [39].

The analysis of TN and IC in the two samples reflect also similar matrix content due to the relatively identical values recorded for the two samples (TN: 2.42 and 2.08 mg L−1, IC: 30.33 and 24.83 mg L−1). Concerning the ions, a variation has to be outlined between the amounts of CO32−, Cl, NO3 and SO42− detected inside the two water samples.

To summarize, it appears that the macropollution is not distinctly different between both water samples. A slight matrix effect in terms of organic compounds could be anticipated while a non-negligible effect of the ions may be obtained.

3.2 Initial micropollutant concentrations

In the first instance, the initial micropollutants concentrations from the two-sampled waters are considered (Table 3). The concentrations of cyclophosphamide, beta-estradiol, ethinylestradiol, sulfadimethoxine, sulfadimidine and sulfathiazole remain lower than the limit of quantification of the LC–MS/MS for the two waters. Consequently, the efficiency of the degradation process towards the removal of these micropollutants cannot be evaluated. For the other contaminants, their concentrations fall within the ng L−1 levels, i.e. from few ng L−1 to hundreds ng L−1. The contaminants concentrations depend on many factors such as sampling date, time of the day, weather, raining periods, etc. The micropollutant amounts are lower in the water sampled in March than that collected in October. This is particularly true for the pharmaceutical compounds. This can be attributed to a more important utilization of drugs medicines in October than in March and difference of river flow-rates. As an example, the clarithromycin antibiotic is significantly more abundant in October (703 ng L−1) compared to that reported in March (16 ng L−1). The same conclusion can be drawn with sulfamethoxazole, which is another antibiotic. Another illustration of this aspect is given with erythromycin and carbamazepine 10,11-epoxide, with respective concentrations of 1006 and 3 ng L−1 in the water collected in October, whereas their contents are lower than the limit of quantification for the water sampled in March.

Table 3 Initial concentrations (C0) of the micropollutants inside the river water samples from March 2017 and October 2016

3.3 Direct photolysis

Photolysis experiments were conducted in the absence of catalyst under UV illumination for 30 min and 6 h (Fig. 1a). The photolysis efficiency can be estimated using:

$${\text{Photolysis}} = \left( {\frac{{{\text{C}}_{ 0} - {\text{C(t,}}\;{\text{UV)}}}}{{{\text{C}}_{ 0} }}} \right) \times 100$$
(1)

where C0 is the initial micropollutant concentration, C(t, UV) represents the micropollutant concentration after 30 min (C(30 min, UV)) or 6 h (C(6 h, UV)) of UV treatment in the absence of catalyst.

Fig. 1
figure 1

a Photolysis efficiency towards the degradation of the micropollutants after 30 min (“30 min UV”) and 6 h (“6 h UV”) of UV treatment with river water sample from March 2017. b Blank experiments in the simultaneous presence of UV and H2O2 towards the degradation of the micropollutants after 30 min (“30 min UV + H2O2”) and 6 h (“6 h UV + H2O2”) of treatment with river water sample from March 2017

For most of the micropollutants, no variation of the concentrations is detected after 30 min and 6 h of illumination. This emphasizes that the photolysis effect is negligible for bisphenol A, carbamazepine, clarithromycin, estrone, ibuprofen, lidocaine, PFOA, PFOS, sulfamethoxazole and triclosan (Photolysis = 0–6%). Similar absence of photodegradation was previously reported for carbamazepine, clarithromycin and sulfamethoxazole [21, 40]. In addition, the negligible photolysis of estrone corresponds well to the results reported by Sornalingam et al. [23]. This behavior was attributed to the lack of light absorption by this pollutant. However, three microcontaminants need to be discussed. For naproxen, a slight photolysis effect is noticed since the photolysis efficiency becomes equal to 14% after 6 h of irradiation. The complete removal of ketoprofen occurs after 6 h of photolysis process (Photolysis = 100%). It is difficult to discriminate between the photolysis and the photocatalytic or photo-Fenton effects during the degradation of this contaminant. In addition, the photolysis effect cannot be neglected with diclofenac since the photolysis efficiency reaches 47% after 6 h of illumination. Bernabeu and coworkers [40] reached the same type of conclusion. They indicated that the photolysis of diclofenac was around 10% for an initial concentration of 300 ng L−1.

A second set of degradation experiments were conducted, in the absence of catalyst, under UV illumination and in the presence of H2O2 (Fig. 1b). For the majority of the micropollutants, the simultaneous presence of light and H2O2 leads to greater degradation of the contaminants than the photolysis. The reaction between UV and H2O2 produces ·OH hydroxyl radicals. The larger degradation of the micropollutants is due to the presence of the ·OH. The total degradation of ketoprofen takes place after 6 h of process. The degradation efficiency remains high for diclofenac (60%), naproxen (40%), clarithromycin (40%), bisphenol A (30%) and carbamazepine (30%) after 6 h of process. On the opposite, the removal remains weak for triclosan, lidocaine, estrone, PFOS, while it is negligible for ibuprofen and sulfamethoxazole.

3.4 Adsorption of the micropollutants onto TiO2 and iron-impregnated faujasite

To investigate the adsorption of the micropollutants onto TiO2 and iron-impregnated faujasite, the contaminants concentration is analyzed after 2 h of contact between the water and the catalyst. The adsorption efficiency of the catalyst is given by:

$${\text{R}}_{\text{a}} = \left( {\frac{{{\text{C}}_{ 0} - {\text{C}}\left( { 2\,{\text{h dark adsorption}}} \right)}}{{{\text{C}}_{ 0} }}} \right) \times 1 0 0$$
(2)

where C(2 h dark adsorption) stands for the remaining contaminants concentration after 2 h of contact between the water and the catalyst. The adsorption efficiencies obtained with the two catalysts for the two samplings performed at different periods are reported in Fig. 2.

Fig. 2
figure 2

Adsorption efficiency Ra of TiO2 (“TiO2”) and iron-impregnated faujasite (“Faujasite”) towards the micropollutants from the waters sampled in a March 2017 and b October 2016. “carba10,11epoxide” indicates carbamazepine 10,11-epoxide

In the presence of TiO2, among all the quantified micropollutants, only carbamazepine-10,11-epoxide is totally adsorbed after 2 h of stirring in the dark for the water sampled in October 2016 (Ra = 100%). The initial concentration of carbamazepine-10,11-epoxide is low (3.3 ng L−1) and close to its limit of quantification given as 3.0 ng L−1. The absence of adsorption of ibuprofen, PFOA and erythromycin onto TiO2 is also highlighted. For the other micropollutants, the adsorption efficiency Ra ranges between 9 and 49%, with the majority of the Ra around 10–20%. It can be concluded that the micropollutants adsorption remains low onto TiO2. Consequently, these micropollutants cannot be efficiently removed by adsorption over TiO2. This is not surprising since TiO2 possesses a low specific surface area (59 m2/g) and no apparent porosity [34, 35].

The iron-impregnated faujasite displays a different behavior in terms of micropollutant adsorption. The complete adsorption (Ra = 100%) of carbamazepine, carbamazepine-10,11-epoxide, estrone, lidocaine, PFOS, naproxen and triclosan occurs regardless of the initial micropollutant concentration. At the same time, diclofenac and bisphenol A, are totally adsorbed onto the iron-impregnated faujasite for the river water sample from March 2017, which present the lower initial concertation. For the other micropollutants such as clarithromycin (Ra = 45–58%), erythromycin (Ra = 45%), ibuprofen (Ra = 62–63%) and ketoprofen (Ra = 58–62%), the adsorption efficiencies remain at a high level. Conversely, only for sulfamethoxazole (Ra = 6–17%) and PFOA (Ra = 9–37%), the adsorption efficiency is low.

To summarize, the adsorbed amounts of all the micropollutants are higher onto the iron-impregnated faujasite compared to those onto TiO2. The better adsorption properties of the iron-impregnated faujasite are confirmed by carbon analysis performed with the sample of water collected in October (Table 4). The initial NPOC of 4.3 mg C L−1 decreases to 2.9 and 3.5 mg C L−1 at the end of the adsorption period in the presence of iron-impregnated faujasite and TiO2, respectively. Analogously, the IC of 30.3 mg C L−1 drops to 16.1 and 25.3 mg C L−1 after contact with the iron-impregnated faujasite and the TiO2, respectively. These results can be explained by the surface area of iron-impregnated faujasite (640 m2 g−1) that is greater than the one of TiO2 (59 m2 g−1).

Table 4 Concentration of non-purgeable organic carbon (NPOC) and inorganic carbon (IC) before and after treatment by photocatalysis with TiO2 and by photo-Fenton with iron-impregnated faujasite in river water sample from October 2016

3.5 Degradation of the micropollutants through photocatalysis and photo-Fenton processes

The photocatalytic and photo-Fenton removal of the micropollutants is studied. After the adsorption period, the concentrations of the different compounds are estimated after 30 min and 6 h under UV irradiation in the presence of TiO2 or iron-impregnated faujasite. The removal percentage can be expressed as:

$${\text{X(t)}} = \left( {\frac{{{\text{C}}_{ 0} - {\text{C(t)}}}}{{{\text{C}}_{ 0} }}} \right) \times 100$$
(3)

where C(t) represents the micropollutant concentration after 30 min (C(30 min)) or 6 h (C(6 h)) of process (photocatalysis or photo-Fenton). Note that the removal percentage of 100% does not necessarily indicate the complete mineralization of the contaminant. For instance, a weak carbon content ([NPOC] = 2.67 mg C L−1 and 2.44 mg C L−1) remains after 6 h of photocatalysis and photo-Fenton for the water sampled in October (Table 4). These carbon contents correspond to the whole matrix, which might include some originating by-products produced during the degradation and/or the other micro or macrocontaminants not degraded by the process. The low carbon content ([NPOC]) measured at the end of the reactions, is an important indication for high mineralization of the micropollutants and negligible toxicity.

The removal percentages are given in Fig. 3a, b for the sampling performed in March and October, respectively. In a first approach, to compare the efficiency of the two processes, the results are discussed based on the removal efficiency after 6 h of process (X(6 h)). During 6 h of photocatalytic and photo-Fenton treatments, the main part of the micropollutants is removed, i.e. X(6 h) equals 100%. Carbamazepine, carbamazepine-10,11-epoxide, clarithromycin, diclofenac, estrone, ketoprofen, lidocaine, naproxen and triclosan are totally removed by the two processes for the two initial concentrations. For the other micropollutants, the removal percentage is generally greater using the photo-Fenton process than with the photocatalytic degradation. For bisphenol A and PFOS, X(6 h) increases, respectively, from 65–75% to 94–100%, and from 36–56% to 88–100%, when the TiO2 photocatalyst is replaced by the photo-Fenton catalyst. However, the removal efficiency towards ibuprofen is similar for the two processes (X(6 h) = 93–100%). Conversely, the photocatalytic process leads to the total degradation of initial sulfamethoxazole concentrations of 35 and 6 ng L−1, while the photo-Fenton treatment produces only partial degradation with X(6 h) values of 54% and 74%, respectively. The photocatalytic performances are similar to those described by Miralles-Cuevas et al. [26] for the photodegradation of diclofenac and naproxen. The authors reported a total disappearance of 1500 ng L−1 of diclofenac and 3000 ng L−1 of naproxen after 4 h under solar light irradiation. At the same time, the complete removal of ibuprofen (750 ng L−1) was achieved in 2 h. The degradation results are in accordance with the data reported by Bernabeu and coworkers [40] for the removal of clarithromycin, diclofenac and carbamazepine from a mixture containing nine emerging contaminants at concentrations around 50–100 ng L−1. The entire photocatalytic decomposition of sulfamethoxazole corresponds perfectly with previously reported findings [41, 42].

Fig. 3
figure 3

Removal percentages of the micropollutants by photocatalysis with TiO2 catalyst (“30 min TiO2”, “6 h TiO2”) and by photo-Fenton using iron-impregnated faujasite system (“30 min Faujasite”, “6 h Faujasite”) from the waters sampled in a March 2017 and b October 2016. “carba10,11epoxide” indicates carbamazepine 10,11-epoxide

It appears interesting to find a relation between the removal efficiency and the physico-chemical characteristics of each micropollutant. The removal of micropollutants depends on their physico-chemical properties such as pKa, solubility, octanol–water partition coefficient Kow and Henry’s constant. In the present study, log Kow, which is a hydrophobicity parameter, seems to play a role. The Table 5 lists the log Kow of the micropollutants with the removal percentages after 6 h of photocatalysis and photo-Fenton processes. The log Kow of all the micropollutants range between 0.79 and 4.3. For the pollutant with low log Kow (0.79), the total removal of sulfamethoxazole occurs only with photocatalysis. Sulfamethoxazole has a very low Kow value (0.79) compared to the others micropollutants, for which low Kow are larger than or equal to 2.1. Consequently, sulfamethoxazole is the most polar micropollutant among the targeted pollutants. It has a higher interaction affinity with TiO2 for which the hydrophilic character is caused by the hydroxyl groups on the surface. On the opposite, the micropollutants with log Kow between 2.16 and 3.1 behave similarly with total removal under both processes. For the micropollutants with log Kow larger than or equal to 3.3, i.e. bisphenol A and PFOS, their total removal can be obtained by photo-Fenton while the photocatalysis process produces lower removal efficiency. Bisphenol A and PFOS have higher log Kow (3.3 and 4.3, respectively). They possess less hydrophilic character than the other micropollutants which lead to stronger interactions with the hydrophobic iron-impregnated faujasite.

Table 5 Relationship between the log Kow of the micropollutants with the removal percentages after 6 h of photocatalysis and photo-Fenton processes

In order to analyze the kinetic of degradation, it appears practical to discuss the removal efficiency after 30 min of process (X(30 min)). For almost all the micropollutants, the contaminants are totally removed after 30 min by photo-Fenton with iron-impregnated faujasite while a longer period is necessary by photocatalysis with TiO2. For instance, bisphenol A, carbamazepine, clarythromycine, diclofenac, estrone, ketoprofen, lidocaine, naproxen and triclosan are totally removed after 30 min using the photo-Fenton process for the two initial concentrations. Conversely, only estrone, naproxen and triclosan reach X(30 min) = 100% when treated by photocatalysis. The temporal evolutions of the NPOC values support these results (Table 4). The NPOC decreases with the time of process from 3.5 to 3.0 mg C L−1 and 2.7 mg C L−1 after 30 min and 6 h of photocatalysis. In the presence of iron-impregnated faujasite, the NPOC values of the solution after 30 min and 6 h of treatment range between 2.6 and 2.4 mg C L−1. The fastest degradation by photo-Fenton in the presence of iron-impregnated faujasite may arise from the larger amount of adsorbed micropollutants and/or the higher production of radicals. A correlation between the time needed to degrade the pollutant and the contaminant surface coverage was already reported for both photocatalysis and photo-Fenton processes [34, 43, 44]. The previous studies highlighted that a high adsorption of contaminant increases the efficiency of the degradation process. For the second explanation, it can be noticed that the hydroxyl radicals are the major active species during the oxidation reactions. It is assumed that the photo-Fenton process produces a larger amount of ·OH than the photocatalytic reaction. The additional formation of ·OH comes from Fenton reaction through the presence of H2O2. Our results corroborate the other measurements, demonstrating that photo-Fenton systems produced better degradation of the contaminants over TiO2 photocatalysis processes [28,29,30,31]. Dai et al. [45] reached the same conclusion when conducting degradation experiments over carbamazepine (1000 µg L−1). The degradation efficiencies proceeded in the following order ascending sequence: UV photolysis < UV/H2O2 < Fenton < UV/TiO2 < UV/photo-Fenton. Our results follow the same order with the real water containing the cocktail of microcontaminants.

It is also relevant to conduct an economical evaluation of both AOPs systems to evaluate which is the better one in terms of cost. In a first approach, the costs of the reagents is estimated. The costs of reagents (TiO2, faujasite, H2O2, iron (III) nitrate nonahydrate) are calculated as the concentration used (C) multiplied by the unit price of the product (P). They read as \([ {\text{C}} \times {\text{P]}}\). For photocatalysis process [\({\text{C}} \times {\text{P}}\)]Photocatalysis, is mainly due to the TiO2. Conversely, for photo-Fenton process, [\({\text{C}} \times {\text{P}}\)]Photo-Fenton takes into account the costs of the faujasite, the iron (III) nitrate nonahydrate used to prepare the iron-impregnated faujasite and the hydrogen peroxide.

$${\text{Photocatalysis}}\;{\text{cost}} = \left[ {{\text{C}} \times {\text{P}}} \right]_{\text{Photocatalysis}} = {\text{C}}_{{{\text{TiO}}_{2} }} \times {\text{P}}_{{{\text{TiO}}_{2} }}$$
(4)
$${\text{Photo-Fenton}}\;{\text{cost}}\, = \,{\text{C}}_{\text{faujasite}} \, \times \,{\text{P}}_{\text{faujasite}} \, + \,{\text{C}}_{{{\text{Fe}}\left( {{\text{NO}}_{3} } \right)3}} \, \times \,{\text{P}}_{{{\text{Fe}}\left( {{\text{NO}}_{3} } \right)3}} \, + \,{\text{C}}_{{{\text{H}}_{2} {\text{O}}_{2} }} \, \times \,{\text{P}}_{{{\text{H}}_{2} {\text{O}}_{2} }}$$
(5)

According to the market, the price of TiO2 ranges between 1800 and 2000 euros/ton, the price for faujasite is equal to 75–140 euros/ton, Fe(NO3)3 costs 500–800 euros/ton, while H2O2 costs 0.747 euro/kg. The calculation is conducted for 1 ton of TiO2 for photocatalysis and 1 ton of faujasite for photo-Fenton. For the calculation, it is considered that for 1 ton of catalyst (TiO2 or iron-impregnated faujasite), TiO2 has a cost of 2000 euros, faujasite 120 euros, Fe(NO3)3,120 euros (20 wt% of iron), and H2O2 177 euros (0.007 mol/L or 0.238 g/L). The photocatalysis cost [\({\text{C}} \times {\text{P}}\)]Photocatalysis is evaluated as 2000 euros/ton of TiO2 while the photo-Fenton cost [\({\text{C}} \times {\text{P}}\)]Photo-Fenton is equal to 417 euros/ton of faujasite. It can be deduced that the total price of the reagents used for photo-Fenton process is substantially less expensive than that used for photocatalysis. This is mainly due to the expansive price of TiO2 P25.

In the previous calculation, only the cost of the reagents was estimated. The total cost (TC) of the process is also affected by the operating cost (OC) of the process, which depends on the time of reaction tR, as well as the amortization costs of the investment (AC). In the present study, since we use a batch laboratory scale process, the price of several parameters is not easy to estimate in real plant conditions. The maintenance cost, working hours per day, amortization cost are some examples. To evaluate the operating cost, we use the approach developed by Santos-Juanes Jorda et al. [46]. This equation was developed for a pilot plant based in Almeria (Spain). The total cost per m3 of water treated is calculated as [46]:

$${\text{TC(euros/m}}^{ 3} )= {\text{AC}} + {\text{OC}} = 0. 0 7 1 2+ [ {\text{C}} \times {\text{P]}} + 1. 2 3 2 9\times {\text{t}}_{\text{R}} + 0. 0 0 4 2\times {\text{t}}_{\text{R}}^{ 2}$$
(6)

This equation shows the linear and quadratic effects of the reaction time tR on the total cost of the process. The Table 6 gives the economic and cost evaluation of the photocatalysis and photo-Fenton processes for treatment of the micropollutants. The time of reaction tR depends on the process and also on the nature of the micropollutants. For this reason, the TC are calculated for tR varying between 0.5 and 6 h for both processes. The results indicate that the total cost of the photocatalysis process is higher than that of photo-Fenton regardless of the reaction time. When tR equals 30 min, the cost of photocatalysis is the double of that of photo-Fenton. Conversely, after 6 h of process the cost of the two processes becomes closer (TC(photocatalysis)/TC(photo-Fenton) = 1.19). Based on these considerations, it can be concluded that the photo-Fenton process for the removal of the 21 micropollutants is the cheaper. This is particularly true since the majority of the micropollutants are removed after 30 min of photo-Fenton process while it takes 6 h to reach the complete removal using photocatalysis.

Table 6 Economic and cost evaluation of the photocatalysis and photo-Fenton processes for treatment of the micropollutants. TC is the total cost per m3 of water treated

For ibuprofen, ketoprofen, and triclosan, the initial concentrations are similar between the two waters (Table 3). These pollutants can be analyzed to assess the influence of the water matrix composition on the adsorption and photodegradation processes (photocatalysis and photo-Fenton). Recent studies showed that the photocatalytic performances are adversely impacted by the wastewater matrix [20,21,22,23]. In general, the constituents present in the wastewater lowered the degradation rate of the micropollutants due to the quenching of the ·OH by the organic matters, humic acid, inorganic ions such as Cl, NH4+, NO3, HCO3 [23]. Here, in both cases, the photocatalytic treatment leads to the disappearance of triclosan after 30 min of irradiation (Fig. 3). For ketoprofen, the complete removal (X = 100%) takes place during 6 h of photocatalysis for the two samplings. More remarkably, the removal percentages after 30 min of treatment are very close, i.e. X(30 min) = 8 and 10%. For ibuprofen, the photocatalytic removal efficiencies remain similar during the whole process: X(30 min) = 9–10% and X(6 h) = 93–94%. These data emphasise that the photocatalytic removal of the micropollutants is not affected by the water matrix. This result was expected since the physicochemical characteristics of the two water samples do not differ significantly in terms of macropollutants (Table 2). The same trend is reported also with the photo-Fenton process. For the two waters, the photo-Fenton treatment produces the disappearance of triclosan after 30 min. The adsorbed amounts of ketoprofen onto the iron-impregnated faujasite remain very close (Ra = 58 and 62%). In the special case of ibuprofen, the kinetic of degradation does not quantitatively differ between the two periods: X(30 min) = 90–100% and X(6 h) = 94–100%.

4 Conclusions

The aim of this paper was to study and compare the degradation of a large variety of micropollutants in real water samples from a river using the photocatalysis conventional TiO2/UV system and iron-impregnated faujasite photo-Fenton process. The samples have been collected from the Meurthe River in the vicinity of the city of Nancy in France. To address the influence of the water matrix composition and the micropollutants concentrations, the sampling campaigns have been conducted at two different periods of the year. Twenty one micropollutants including 14 pharmaceutical compounds, 1 personal care product, 4 endocrine disruptors and 2 perfluorinated molecules have been detected, quantified and degraded. All the initial concentrations appear in the range of ng L−1 since they range between 0.8 and 140 ng L−1.

The adsorption of all the micropollutants is higher onto the iron-impregnated faujasite compared to that onto TiO2. This is attributed to the larger surface area of the iron-impregnated faujasite as compared to that of TiO2. The iron-impregnated faujasite offers superior photo-Fenton oxidation efficiency towards the degradation of the micropollutants over the TiO2 photocatalysis system. During 6 h of photocatalytic and photo-Fenton treatments, carbamazepine, carbamazepine-10,11-epoxide, clarithromycin, diclofenac, estrone, ketoprofen, lidocaine, naproxen and triclosan are totally removed by the two processes for the two initial concentrations. For the other micropollutants, the removal percentage is greater using the photo-Fenton process than with the photocatalytic degradation. A relation between the removal efficiency and log Kow of each micropollutant can be deduced from the data. For the pollutant with low log Kow (0.79), the total removal of the micropollutant occurs only with photocatalysis. For the micropollutants with log Kow between 2.16 and 3.1, the total removal of the micropollutants is obtained under both processes. For the micropollutants with log Kow larger than or equal to 3.3, the total removal of the microcontaminants can be only obtained by photo-Fenton.

The removal efficiency after 30 min of process is used to evaluate the kinetic of the two processes. For almost all the micropollutants, the contaminants are totally degraded after 30 min by photo-Fenton with iron-impregnated faujasite while a longer period is necessary by photocatalysis with TiO2. The fastest photo-Fenton degradation in the presence of iron-impregnated faujasite arises from the larger amount of adsorbed micropollutant onto the iron-impregnated faujasite and the higher production of radicals due to the addition of H2O2. This latter aspect need to be experimentally verified. In addition, the economical evaluation reveals that the photo-Fenton process is more economic as compared to photocatalysis process. This is due to the high price of TiO2 and the shorter time of reaction during photo-Fenton process.