Skip to main content

Table 3 Reservoir inflow, surface elevation, turbine discharge and power output

From: Performance evaluation of Kainji hydro-electric power plant using artificial neural networks and multiple linear regression

S/no. Reservoir inflow (m2/s) Water surface elevation (m) Turbine discharge (m3/s) Power generated (MW)
1 1513 140.71 991 373.77
2 1638 141.66 856 305.07
3 1688 139.3 1233 387.87
4 1750 141.09 1199 403
5 1380 141.38 1161 395.42
6 1505 141 937 319.65
7 1080 139.79 804 261.91
8 1593 141.12 424 141.69
9 1350 140.97 2 0.02
10 1280 140.29 295 97
11 924 140.84 904 334.62
12 1294 141.42 774 277.99
13 1340 139.63 1202 410.34
14 1632 141.49 1102 369.69
15 1323 141.31 1135 388.87
16 1546 141.24 859 295.33
17 908 139.48 858 290.73
18 1531 141.47 430 141.6
19 1186 140.57 162 46
20 1069 139.94 379 127
120 1202 141.2 801 269.34