Experimental Study On Shear Performance of Steel–Concrete Composite Bolted Connectors in Precast Concrete Shear Walls

Abstract

To explore the shear performance of steel-concrete composite bolted (SCCB) connectors used in precast reinforced concrete (RC) shear walls, 16 specimens were designed and tested under monotonic loading, taking the bolt diameter, bolt pretension force, bolt hole diameter, concrete compressive strength, sandwich concrete thickness, thickness of inner plate and cap plate into consideration. The failure modes, load-slip curves, bolt force, shear bearing capacity as well as the shear stiffness of the tested specimens were obtained accordingly. Test results demonstrated that two failure modes involved bolt shear failure and bearing failure were observed in all specimens, the failure mode that was experienced mainly depended on bolt diameter, inner plate thickness and cap plate thickness. The peak load for specimen with bolt diameters of 16 mm showed an improvement of over 52% than that with bolt diameters of 24 mm, but the variation of shear stiffness was less than 8.1%. About 16.6% and 23.5% increase in peak load and shear stiffness for specimen with C50 concrete was observed than specimen with C30 concrete. Compared to specimen with cap plate thickness of 6 mm, the peak load and shear stiffness of specimen with cap plate thickness of 14 mm are increased by 9.8% and 56.2%, respectively. In addition, the sandwich concrete thickness, bolt pretension force, bolt hole diameter and inner plate thickness had only a minor influence on the peak load and shear stiffness of the SCCB connectors.

This is a preview of subscription content, access via your institution.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16
Fig. 17
Fig. 18

References

  1. 1.

    Yee AA, Eng PHD (2001) Structural and economic benefits of precast/prestressed concrete construction. PCI J 46(4): 34–42. https://doi.org/10.15554/pcij.07012001.34.42

  2. 2.

    VanGeem M (2006) Achieving Sustainability with Precast Concrete. PCI J 51(1):42–61. https://doi.org/10.15554/pcij.01012006.42.61

  3. 3.

    Brunesi E, Peloso S, Pinho R, Nascimbene R (2018) Cyclic testing of a full-scale two-storey reinforced precast concrete wall-slab-wall structure. B Earthq Eng 16(11):5309–5339. https://doi.org/10.1007/s10518-018-0359-z

    Article  Google Scholar 

  4. 4.

    Soudki KA, Rizkalla SH, LeBlanc B (1995) Horizontal connections for precast concrete shear walls subjected to cyclic deformations part 1: mild steel connections. PCI J 40(4): 78–96. https://doi.org/10.15554/pcij.07011995.78.96

  5. 5.

    Shah YI, Hu Z, Yin BS, Li X (2021) Flexural performance analysis of UHPC wet joint of prefabricated bridge deck. Arab J Sci Eng. https://doi.org/10.1007/s13369-021-05735-z

    Article  Google Scholar 

  6. 6.

    Seifi P, Henry RS, Ingham JM (2019) In-plane cyclic testing of precast concrete wall panels with grouted metal duct base connections. Eng Struct 184:85–98. https://doi.org/10.1016/j.engstruct.2019.01.079

    Article  Google Scholar 

  7. 7.

    Hofheins CL, Reaveley LD, Pantelides CP (2002) Behavior of welded plate connections in precast concrete panels under simulated seismic loads. PCI J 47(4): 122–133. https://doi.org/10.15554/pcij.07012002.122.133

  8. 8.

    Wang W, Zhang X, Zhou X, Wu L, Zhu H (2021) Study on shear behavior of multi-bolt connectors for prefabricated steel-concrete composite beams. Front Mater 8:625425. https://doi.org/10.3389/fmats.2021.625425

    Article  Google Scholar 

  9. 9.

    Dal Lago B, Biondini F, Toniolo G (2017) Friction-based dissipative devices for precast concrete panels. Eng Struct 147:356–371. https://doi.org/10.1016/j.engstruct.2017.05.050

    Article  Google Scholar 

  10. 10.

    Kurama Y, Pessiki S, Sause R, Lu L (1999) Seismic behavior and design of unbonded post-tensioned precast concrete walls. PCI J 44(3): 72–89. https://doi.org/10.15554/pcij.05011999.72.89

  11. 11.

    Sun J, Qiu H, Lu B (2015) Experimental validation of horizontal joints in an innovative totally precast shear wall system. J SE Univ 31(1):124–129. https://doi.org/10.3969/j.issn.1003-7985.2015.01.021

  12. 12.

    Sun J, Qiu H, Jiang H (2019) Experimental study and associated mechanism analysis of horizontal bolted connections involved in a precast concrete shear wall system. Struct Concrete 20(1):282–295. https://doi.org/10.1002/suco.201800113

    Article  Google Scholar 

  13. 13.

    Jiang H, Qiu H, Sun J, Del Rey CE, Ingham JM (2020) Influence of friction-bearing devices on seismic behavior of PC shear walls with end columns. Eng Struct 210:110293. https://doi.org/10.1016/j.engstruct.2020.110293

    Article  Google Scholar 

  14. 14.

    Fang Q, Qiu H, Sun J, Dal Lago B, Jiang H (2021) Performance study of precast reinforced concrete shear walls with steel columns containing friction-bearing devices. Arch Civ Mech Eng 21:110. https://doi.org/10.1007/s43452-021-00261-z

    Article  Google Scholar 

  15. 15.

    Sun J, Qiu H, Lu Y (2016) Experimental study and associated numerical simulation of horizontally connected precast shear wall assembly. Struct Des Tall Special Build 25(13):659–678. https://doi.org/10.1002/tal.1277

    Article  Google Scholar 

  16. 16.

    Pavlović M, Marković Z, Veljković M, Buđevac D (2013) Bolted shear connectors vs. headed studs behaviour in push-out tests. J Constr Steel Res 88:134–149. https://doi.org/10.1016/j.jcsr.2013.05.003

    Article  Google Scholar 

  17. 17.

    Liu X, Bradford MA, Lee MSS (2015) Behavior of high-strength friction-grip bolted shear connectors in sustainable composite beams. J Struct Eng 141(6):4014149. https://doi.org/10.1061/(ASCE)ST.1943-541X.0001090

    Article  Google Scholar 

  18. 18.

    Kwon G, Engelhardt MD, Klingner RE (2010) Behavior of post-installed shear connectors under static and fatigue loading. J Constr Steel Res 66(4):532–541. https://doi.org/10.1016/j.jcsr.2009.09.012

    Article  Google Scholar 

  19. 19.

    Zhang Y, Liu A, Chen B, Zhang J, Pi Y, Bradford MA (2020) Experimental and numerical study of shear connection in composite beams of steel and steel-fibre reinforced concrete. Eng Struct 215:110707. https://doi.org/10.1016/j.engstruct.2020.110707

    Article  Google Scholar 

  20. 20.

    Ataei A, Zeynalian M (2021) A study on structural performance of deconstructable bolted shear connectors in composite beams. Structures 29:519–533. https://doi.org/10.1016/j.istruc.2020.11.065

    Article  Google Scholar 

  21. 21.

    Zhao W, Lu S, Jing X (2020) Shear performance of high-strength bolt connector considering different pad and bolt hole. Structures 28:1291–1300. https://doi.org/10.1016/j.istruc.2020.09.050

    Article  Google Scholar 

  22. 22.

    GB 50017–2017 (2017) Code for design of steel structures. China Architecture & Building Press, Beijing

  23. 23.

    JGJ 82–2011 (2011) Technical specification for high strength bolt connections of steel structures. China Building Industry Press, Beijing

  24. 24.

    GB/T 228.1–2010 (2010) Metallic materials-tensile testing-part 1: method of test at room temperature. China Standard Press, Beijing

  25. 25.

    GB/T 50081–2002 (2002) Standard for test method of mechanical properties on ordinary concrete. China Architecture & Building Press, Beijing

  26. 26.

    Jiang H, Qiu H, Sun J, Yang Y (2019) Behavior of steel-concrete composite bolted connector in precast reinforced concrete shear wall. Adv Struct Eng 22(12):2572–2582. https://doi.org/10.1177/1369433219846957

    Article  Google Scholar 

  27. 27.

    Kong J (2017) Study on shear behavior of high-strength bolt using for connecting steel-concrete composite member. Master's Thesis, Southeast University

  28. 28.

    Li X, Hu Z, Fan L, Shah YI (2019) Experimental investigation of perfobond hoop shear connector, s bearing capacity and slip. Eng Struct 198:109461. https://doi.org/10.1016/j.engstruct.2019.109461

    Article  Google Scholar 

  29. 29.

    Kim TS, Kuwamura H, Cho TJ (2008) A parametric study on ultimate strength of single shear bolted connections with curling. Thin-Wall Struct 46(1):38–53. https://doi.org/10.1016/j.tws.2007.08.009

    Article  Google Scholar 

  30. 30.

    Rex CO, Easterling WS (2003) Behavior and modeling of a bolt bearing on a single plate. J Struct Eng 129(6):792–800. https://doi.org/10.1061/(ASCE)0733-9445(2003)129:6(792)

    Article  Google Scholar 

  31. 31.

    Rogers CA, Hancock GJ (2000) Failure modes of bolted-sheet-steel connections loaded in shear. J Struct Eng 126(3):288–296. https://doi.org/10.1061/(ASCE)0733-9445(2000)126:3(288)

    Article  Google Scholar 

  32. 32.

    Mahmood M, Elamin A, Tizani W (2020) Ultimate strength and fracture sequence of bolted connections to thin-walled carbon steel. Structures 23:646–659. https://doi.org/10.1016/j.istruc.2019.11.011

    Article  Google Scholar 

  33. 33.

    Fang Z, Liang W, Fang H, Jiang H, Wang S (2021) Experimental investigation on shear behavior of high-strength friction-grip bolt shear connectors in steel-precast UHPC composite structures subjected to static loading. Eng Struct 244:112777. https://doi.org/10.1016/j.engstruct.2021.112777

    Article  Google Scholar 

  34. 34.

    Yang F, Liu Y, Xin H, Veljkovic M (2021) Fracture simulation of a demountable steel-concrete bolted connector in push-out tests. Eng Struct 239:112305. https://doi.org/10.1016/j.engstruct.2021.112305

    Article  Google Scholar 

Download references

Acknowledgements

The authors gratefully acknowledge the financial support from the the National Nature Science Foundation of China (51708107) and the Jiangsu Natural Science Foundation (BK20170668).

Author information

Affiliations

Authors

Contributions

QF: methodology, investigation, validation, data curation, visualization, writing-original draft. HQ: supervision. JS: methodology, supervision. HJ: investigation, writing-original draft. YY: investigation, writing-original draft.

Corresponding author

Correspondence to Hongxing Qiu.

Ethics declarations

Conflict of interest

The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Rights and permissions

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Fang, Q., Qiu, H., Sun, J. et al. Experimental Study On Shear Performance of Steel–Concrete Composite Bolted Connectors in Precast Concrete Shear Walls. Int J Civ Eng (2021). https://doi.org/10.1007/s40999-021-00676-y

Download citation

Keywords

  • Precast concrete shear walls
  • Steel-concrete composite bolted connectors
  • High-strength bolts
  • Load-slip curves
  • Shear bearing capacity
  • Shear stiffness