Abstract

In the present study, the dynamics of a red blood cell (RBC) in a simple microchannel and in a microchannel with obstacle is simulated using combined lattice Boltzmann-immersed boundary method. The fluid flow field is solved for using LBM and the interaction between the fluid and the RBC is simulated using the IBM. The RBC is considered as a deformable boundary immersed in the fluid flow. When the RBC is stiffer, the flow passage is further blocked due to the lack of flexibility of the RBC causing the flow velocity to decrease and greater drag force (resistance force against the motion of cell) from the fluid to be exerted on it. As a result, the pressure around the RBC increases and becomes even higher than the inlet pressure of microchannel. This increased pressure is thought to be the reason of many serious diseases including cardiovascular diseases. If the number of RBCs used in the simulation increases, the pressure increase would be more appreciable. In addition, the high-flexibility RBC experienced tank-treading motion due to its low elastic and bending coefficients whereas for the low-flexibility RBC the tumbling motion took place. The mechanical properties of RBCs are the determining factor in the distribution of hematocrit in microcirculation. The current results showed good agreement with the available results.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12

Similar content being viewed by others

References

  • Alizadeh A, Dadvand A (2016) Simulation of the motion of two elastic membranes in Poiseuille shear flow via a combined immersed boundary-lattice Boltzmann method. J Comput Sci 12:51–61

    Google Scholar 

  • Alizadeh A, Dadvand A (2018a) Effects of deformability of RBCs on their dynamics and blood flow passing through a stenosed microvessel: an immersed boundary-lattice Boltzmann approach. Theor Comput Fluid Dyn 32(1):91–107

    MathSciNet  Google Scholar 

  • Alizadeh A, Dadvand A (2018b) Hydrodynamic interaction of elastic membranes in a stenosed microchannel. Appl Math Model 54:361–377

    MathSciNet  Google Scholar 

  • Attard M (2003) Finite strain-isotropic hyperelasticity. Int J Solids Struct 17:4353–4378

    MATH  Google Scholar 

  • Bächer C, Schrack L, Gekle S (2017) Clustering of microscopic particles in constricted blood flow. Phys Rev Fluids 2(1):013102

    Google Scholar 

  • Bagchi P (2007) Mesoscale simulation of blood flow in small vessels. Biophys J 92:858–877

    Google Scholar 

  • Cabrales P, Tsai AG, Intaglietta M (2008) Increased plasma viscosity prolongs microhemodynamic conditions during small volume resuscitation from hemorrhagic shock. Resuscitation 77:379–386

    Google Scholar 

  • Cheng Y, Zhang H (2010) Immersed boundary method and lattice Boltzmann method coupled FSI simulation of mitral leaflet flow. Comput Fluids 39:871–881

    MathSciNet  MATH  Google Scholar 

  • Eggleton CD, Popel AS (1998) Large deformation of red blood cell ghosts in a simple shear flow. Phys Fluids 10:1834–1845

    Google Scholar 

  • El-Kareh AW, Secomb TW (2000) A model for red blood cell motion in bifurcating microvessels. Int J Multiph Flow 26:1545–1564

    MATH  Google Scholar 

  • Enden G, Popel AS (1992) A numerical study of the shape of the surface separating flow into branches in microvascular bifurcations. J Biomech Eng 114:398–405

    Google Scholar 

  • Faivre M, Abkarian M, Bickraj K, Stone A (2006) Geometrical focusing of cells in a microfluidic device: an approach to separate blood plasma. Biorheology 43:147–159

    Google Scholar 

  • Fedosov DA (2011) Quantifying the biophysical characteristics of Plasmodium-falciparum-parasitized red blood cells in microcirculation. Proc Natl Acad Sci 108(1):35–39

    Google Scholar 

  • Feng ZG, Michaelides EE (2004) The immersed boundary-lattice Boltzmann method for solving fluid-particles interaction problems. J Comput Phys 195(2):602–628

    MATH  Google Scholar 

  • Fischer T, Schmid-Schonbein H (1977) Tank treading motion of red blood cell membranes in viscometric flow, behavior of intracellular and extracellular markers. Blood Cells 3:351–365

    Google Scholar 

  • Fischer T, Stohr-Lissen M, Schmid-Schonbein H (1978) The red cell as a fluid droplet: tank tread-like motion of the human erythrocyte membrane in shear flow. Science 202:894–896

    Google Scholar 

  • Fujiwara H, Ishikawa T, Lima R, Matsuki N, Imai Y, Kaji H, Nishizawa M, Yamaguchi T (2009) Red blood cell motions in high-hematocrit blood flowing through a stenosed microchannel. J Biomech 42:838–843

    Google Scholar 

  • Fung YC (1993) Biomechanics: mechanical properties of living tissues. Springer-Verlag, New York

    Google Scholar 

  • Gaehtgens P, Schmid-Schönbein H (1982) Mechanisms of dynamic flow adaptation of mammalian erythrocytes. Naturwissenschaften 69:294–296

    Google Scholar 

  • Goldsmith HL (1971) Red cell motions and wall interactions in tube flow. Fed Proc 30:1578–1590

    Google Scholar 

  • Guckenberger A, Kihm A, John T, Wagner C, Gekle S (2018) Numerical—experimental observation of shape bistability of red blood cells flowing in a microchannel. Soft Matter 14(11):2032–2043

    Google Scholar 

  • Hosseini SM, Feng JJ (2009) A particle-based model for the transport of erythrocytes in capillaries. ChemEngSci 64:4488–4497

    Google Scholar 

  • Hyakutake T, Ohkawa S, Mohri S, Yanase S (2008) Lattice Boltzmann analysis of microvascular constriction flow including red blood cell and liposome-encapsulated hemoglobin. Theor App Mech Jpn 56:215–224

    Google Scholar 

  • Kang M, Ji HS, Kim KC (2008) In-vivo investigation of RBC’s flow characteristics and hemodynamics feature through a microchannel with a micro-stenosis. Int J Biol Biomed Eng 2:1–8

    Google Scholar 

  • Kaoui B, Biros G, Misbah C (2009) Why do red blood cells have asymmetric shapes even in a symmetric flow? Phys Rev Lett 103(18):188101

    Google Scholar 

  • Keller SR, Skalak R (1982) Motion of a tank-treading ellipsoidal particle in a shear flow. J Fluid Mech 120:27–47

    MATH  Google Scholar 

  • Kim J, Kim D, Choi H (2001) An immersed-boundary finite-volume method for simulations of flow in complex geometries. J Comput Phys 171:132–150

    MathSciNet  MATH  Google Scholar 

  • Li H, Fang H, Lin Z, Xu S, Chen S (2004) Lattice Boltzmann simulation on particle suspensions in a two-dimensional symmetric stenotic artery. Phys Rev E 69:031919

    Google Scholar 

  • Ma G, Hua J, Li H (2009) Numerical modeling of the behavior of an elastic capsule in a microchannel flow, the initial motion. Phys Rev E 79(4):046710–046717

    Google Scholar 

  • Mohamad A (2011) Lattice Boltzmann method: fundamentals and engineering applications with computer codes. Springer, New York

    MATH  Google Scholar 

  • Peskin CS (1972) Flow patterns around heart valves: a digital computer method for solving the equations of Motion. Ph.D. thesis, Physiology, Albert Einstein College of Medicine Univ. Microfilms, vol 378, pp. 72–80

  • Pinelli A, Naqavi IZ, Piomelli U, Favier J (2010) Immersed-boundary methods for general finite difference and finite-volume Navier–Stokes solvers. J Comput Phys 229:9073–9091

    MathSciNet  MATH  Google Scholar 

  • Popel AS, Johnson PC (2005) Microcirculation and hemorheology. Annu Rev Fluid Mech 37:43–69

    MathSciNet  MATH  Google Scholar 

  • Pozrikidis C (1995) Finite deformation of liquid capsules enclosed by elastic membranes in simple shear flow. J Fluid Mech 297:123–152

    MATH  Google Scholar 

  • Pozrikidis C (2003) Numerical simulation of the flow-induced deformation of red blood cells. Ann Biomed Eng 31:1194–1205

    Google Scholar 

  • Pries AR, Secomb TW (2003) Rheology of the microcirculation. Clin Hemorheol Microcirc 29:143–148

    Google Scholar 

  • Stoltz JF, Singh M, Riha P (1999) Hemorheology in practice. IOS Press, Amsterbam

    Google Scholar 

  • Sun C, Munn LL (2005) Particulate nature of blood determines macroscopic rheology: a 2-D lattice Boltzmann analysis. Biophys J 88:1635–1645

    Google Scholar 

  • Sun C, Migliorini C, Munn LL (2003) Red blood cells initiate leukocyte rolling in post capillary expansions: a lattice Boltzmann analysis. Biophys J 85:208–222

    Google Scholar 

  • Taira K, Colonius T (2007) The immersed boundary method: a projection approach. J Comput Phys 225:2118–2137

    MathSciNet  MATH  Google Scholar 

  • Tsubota K, Wada S (2010) Elastic force of red blood cell membrane during tank-treading motion: consideration of the membrane’s natural state. Phys Rev E 81:011910

    Google Scholar 

  • Vàzquez BYS, Martini J, Negrete AC, Cabrales P, Tsai AG, Intaglietta M (2009) Microvascular benefits of increasing plasma viscosity and maintaining blood viscosity: counter intuitive experimental findings. Biorheology 46:167–179

    Google Scholar 

  • Wu J, Shu C (2010a) Particulate flow simulation via boundary condition-enforced immersed boundary-lattice Boltzmann scheme. Commun Comput Phys 7(4):793

    MATH  Google Scholar 

  • Wu J, Shu C (2010b) An improved immersed boundary-lattice Boltzmann method for simulating three dimensional incompressible flow. J Comput Phys 229:5022–5042

    MATH  Google Scholar 

  • Xiong W, Zhang J (2010) Shear stress variation induced by red blood cell motion in microvessel. Ann Biomed Eng 38(8):2649–2659

    Google Scholar 

  • Zhang J (2011) Effect of suspending viscosity on red blood cell dynamics and blood flows in microvessels. Microcirculation 18:562–573

    Google Scholar 

  • Zhang J, Johnson PC, Popel AS (2007) An immersed boundary lattice Boltzmann approach to simulate deformable liquid capsules and its application to microscopic blood flows. Phys Biol 4:285–295

    Google Scholar 

  • Zhang J, Johnson PC, Popel AS (2008) Red blood cell aggregation and dissociation in shear flows simulated by lattice Boltzmann method. J Biomech 41:47–55

    Google Scholar 

  • Zhang J, Johnson PC, Popel AS (2009) Effects of erythrocyte deformability and aggregation on the cell free layer and apparent viscosity of microscopic blood flows. Microvasc Res 77:265–272

    Google Scholar 

  • Zhao H, Isfahani AHG, Olson LN, Freund JB (2010) A spectral boundary integral method for flowing blood cells. J Comput Phys 229:3726–3744

    MathSciNet  MATH  Google Scholar 

  • Zhu L, He G, Wang S, Miller L, Zhang X, You Q, Fang S (2011) An immersed boundary method based on the lattice Boltzmann approach in three dimensions, with application. Comput Math Appl 61(12):3506–3518

    MathSciNet  MATH  Google Scholar 

  • Zhao H, Freund JB, Moser RD (2008) A fixed-mesh method for incompressible flow-structure systems with finite solid deformation. J Comput Phys 227:3114–3140

    MathSciNet  MATH  Google Scholar 

Download references

Acknowledgements

The authors wish to thank the Ahvaz Branch, Islamic Azad University, for the financial support.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Reza Esmaily.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ghafouri, A., Esmaily, R. & Alizadeh, A. Numerical Simulation of Tank-Treading and Tumbling Motion of Red Blood Cell in the Poiseuille Flow in a Microchannel With and Without Obstacle. Iran J Sci Technol Trans Mech Eng 43, 627–638 (2019). https://doi.org/10.1007/s40997-018-0233-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40997-018-0233-2

Keywords

Navigation