Introduction

Rheumatoid arthritis (RA) is a chronic inflammatory rheumatic condition involving progressive joint destruction with functional, psychological, and social repercussions, which can be serious for the patient. RA is estimated to affect 0.3–1% of the general population of adults with approximately 200,000 estimated cases in France [1].

MTX is considered the anchor drug on the basis of its efficacy as a monotherapy and on the basis of its ability to increase the efficacy of biological DMARDs when used in combination [2, 3]. MTX reduces comorbidities and mortality in RA [4, 5]. MTX is prescribed in up to 70% of RA patients [6]. The recommended starting dosage is 10–15 mg/week orally followed by rapid dose escalation (typically 5-mg increment every 1–4 weeks) to achieve the optimal dosage corresponding to 15–25 mg/week in most patients [7].

MTX can also be administered subcutaneously (SC) [7, 8]. Several studies and systematic literature reviews pointed out better bioavailability, higher efficacy, similar to better tolerability and better compliance of MTX SC as compared to oral MTX [9,10,11,12]. Even though this does not mean that all patients should be treated with parenteral MTX, it suggests that patients with an inadequate response and/or intolerance to oral MTX may benefit from parenteral MTX [13].

In recent years, the use of subcutaneous injections gained in importance with the development of prefilled syringes containing MTX. Compared to injection by nursing staff, self-injection can increase patients’ treatment adherence and reduce costs for society and patients by decreasing frequency of healthcare professionals’ visits and transport. However, reduced manual dexterity, dependence on others, injection site reactions, and injection pain can impair compliance to MTX injections in patients with RA [14]. Manual injections require grip and dexterity to handle the vial, needle, and syringe and its plunger in case. This could be difficult in case of functional limitations due to joint pain and impaired mobility commonly encountered in RA patients. Prefilled auto-injector (AI) technology is a valuable response to such limitations. AIs automatically insert the needle and deliver a controlled and fixed dose of drug. Minimizing the pain at injection site, they are easy to learn and use and RA patients express a high level of satisfaction [15,16,17]. Few studies have addressed AI effect on RA clinical outcomes [15,16,17]. They relied mainly on usability and patient preference. Head-to-head comparisons of PFS and AI on RA clinical outcomes are lacking [15].

A newly developed prefilled AI containing MTX has been developed for greater patient convenience and ease of use. This prefilled AI is provided with a needle-cover system to automatically prevent needle stick injury that could potentially result in secondary infections. The aim of this study was to evaluate both compliance and clinical outcomes of this newly developed AI versus prefilled syringes containing MTX in patients suffering from RA.

Methods

Compliance with Ethics Guidelines

This study was conducted in accordance with GCP using the guidance documents and practices offered by the International Conference on Harmonization and the European directives 2001/20/CE and ISO 14155, and in agreement with the local regulations.

All procedures performed in studies involving human participants were in accordance with the Comité de Protection des Personnes (CPP) Ouest VI, an Independent Ethics Committee (IEC) in France where the study was performed, and with the 1964 Helsinki Declaration and its later amendments. Informed consent was obtained from all individual participants included in the study.

The final protocol and its amendments were reviewed and approved by the Competent Authority of France, the French National Agency for Medicines and Health Products Safety (ANSM). A voluntary, signed and dated informed consent form was obtained from the patient prior to any trial-related activity. This study was registered under the number NCT02553018 in ClinicalTrials.gov.

Study Design and Patient Population

This was a multicenter, randomized, comparative, non-inferiority, two-parallel-groups, open-label clinical study conducted in rheumatology centers in France. The primary objective of the study was to compare the percentage of good compliers and the change in Health Assessment Questionnaire (HAQ) after 6 months of treatment. Secondary objectives encompassed evolution of quality of life after 6 months of treatment, acceptability of the two injection devices, and preference for any of them. The study also aimed at describing local and general safety. The study hypotheses were (1) the compliance with AI would not be inferior to compliance with PFS, (2) effect of MTX administered with AI on HAQ score would not be inferior to those of PFS.

Adult patients with an established diagnosis of RA (according to ACR/EULAR criteria) [15] and receiving MTX (orally of by injection) for at least 3 months entered the study. They were recruited by private practice or hospital-based rheumatologists. For patients currently treated with oral MTX, the switch decided by the rheumatologist was made for either safety, compliance or efficacy issues. Pregnant or breast-feeding women or patients with contra-indication to MTX were excluded from the study. Patients were randomly allocated to either MTX by AI or MTX by PFS using a prefilled syringe according to a 1:1 ratio (central randomization).

The investigational product was a disposable, fixed, single-dose auto-injector with 25 g/ml MTX. The product was marketed in April of 2017 in France, under the brand name Nordimet® (Nordic Group BV). The reference product was a pre-filled syringe with attached injection needle with 50 mg/ml MTX (Metoject®, medac GmbH). Devices involved similar costs. For instance, in France, prices per milligram of MTX injected (depending on the packaging and out of dispensing fees) range from 1.04 to 2.15€ for PFS to 0.88 to 1.86€ for AI (http://base-donnees-publique.medicaments.gouv.fr—accessed on 16/11/2018). Patients received one MTX injection per week at a posology varying from 7.5 to 25 mg let at physician’s discretion. Different content in mg MTX involved different devices with the corresponding volume to fully inject. Patients received training and instructions for use of the study product by the physician. The allocated treatment was pursued for 6 months, the so-called comparative phase. During a further 6-month non-comparative phase, PFS patients switched to AI. The total study duration per patient was 12 months. At M6 visit, patients who switched from PFS to AI were trained and received instructions for use. During the 6-month comparative phase, patients were asked to visit the physician every other month. During the 6-month non-comparative phase, patients visited the physician at M9 and M12. Products were dispensed by the physician at each visit.

Collected Data

Collected data included demographics, medical and surgical history, comorbidities, history of RA, and vital signs. Ongoing treatments for RA (DMARDs, corticosteroids, folates) were documented at entry and at M2, M6, and M9 visits.

Compliance was assessed at M2, M6, M9, and M12 visits. It was calculated as the ratio of the actual number of injections divided by the planned number of injections since last visit, based on used and unused products returned by the patient at each visit.

HAQ was collected at entry, M6, and M12 visits. HAQ measures the impact of the disease on the physical function. It includes 20 questions scored using a four-level difficulty scale, organized into eight categories. The HAQ score is the mean of the highest score in each of the eight categories, ranging from 0 to 3 [18].

Quality of life was assessed at entry and at M6 visit by the RAQoL, a 30-item validated disease-specific patient-reported outcome measure [19]. Scores on the RAQoL are a sum of all the individual item scores with a range from 0 to 30, with a lower score indicating better quality of life.

RA activity was monitored by the Disease Activity Score (DAS) 28 [20] with ESR (last value available) or CRP if ESR was missing, swollen joints count, tender joints count, morning stiffness, VAS pain, VAS patient’s global assessment of disease activity, VAS physician’s global assessment of disease activity, extra-articular manifestations. DAS 28 was calculated at entry, M2, M6, M9, and M12 visits.

Patients were asked on acceptability at M6 visit using a self-questionnaire with questions answered with a five-point Likert scale. Acceptability encompassed ease of use, satisfaction, pleasantness, motivation for further utilization, reassurance, treatment-related burden, stress during injection, and pain during injection. Patients were asked to express their preference for AI or PFS at M6 visit for those who had a history of PFS before entry and who were randomized to AI. The same question was asked at M12 for patients who were randomized to PFS during the comparative phase and who switched to AI during the non-comparative phase. Information regarding who performed MTX administration was collected at entry and 6 months later.

Local safety was qualitatively evaluated by the physician at each visit on a four-point verbal scale (unsatisfactory to very satisfactory) and adverse events were collected.

Statistical Analyses

Results were expressed as mean ± standard deviation (mean ± SD) for continuous variables and number and percentage for categorical variables. Percentages were calculated on observed data. Good compliers were defined as patients with at least 80% compliance over the comparative 6-month period. The response to DMARD was assessed according to the EULAR criteria based on the DAS28 [21]. Percentage of good compliers was estimated with a two-sided 95% confidence interval (CI) assuming a binomial distribution. Non-inferiority limit was fixed at − 4% between groups (AI–PFS). For percent change in HAQ from baseline to M6, a one-way analysis of variance model was built using group as fixed effect. Computed means by group were presented as well as an estimate of the difference between means (AI–PFS) and 95% two-sided confidence interval. Non-inferiority limit was fixed at − 5% between groups. By convention, percentage change from baseline was set at 400% for patients with HAQ at baseline = 0 and HAQ at the end the comparative phase > 0. This value corresponded to the maximum observed value. Absolute change in HAQ was calculated as (M6-baseline) and compared between groups by a two-way analysis of covariance model with group as fixed effect and baseline score as covariate. Patients overall preference was described at 6 months and 12 months only for patients having used both injection devices. Preference was tested using a Chi-square test for equality of proportions. Other statistical comparisons used Chi-squared tests and Mann–Whitney U tests. As the primary analysis was a non-inferiority analysis, it was conducted in the per protocol (PP) population and confirmed in the full analysis set (FAS) population.

Supposing a 99% rate of good compliers with PFS and a non-inferiority margin of 4%, with the alpha risk set at 5%, 130 patients per group were needed (260 in total) to ensure a power of 80%. Supposing a non-inferiority delta of 5% in percent change in HAQ, 130 patients per group ensured a power of 80% with alpha risk at 5% and standard deviation of 0.125.

The statistical analysis used SAS 9.4 software (SAS Institute, Cary, NC, USA).

Results

Study Population and Baseline Characteristics

A total of 271 patients were selected for the study. Six patients attended inclusion visit (V1) but were not randomized due to the non-respect of inclusion/exclusion criteria, resulting in 265 randomized patients by 50 active centers. Eight randomized patients did not receive the study product, resulting in a population of 257 treated patients involved in the safety analysis set. During the comparative phase, 136 patients were allocated to AI and 129 were allocated to PFS. Among them, at least one co-primary endpoint was missing in 55 patients, leaving 202 patients in the full analysis set (FAS), 101 in each group. Two patients received PFS instead of AI and three patients received AI instead of PFS. Misallocation was considered as a major protocol violation and these patients were excluded from the PP population which involved 197 patients (99 AI and 98 PFS). Forty-eight patients withdrew from the study during the comparative phase: 26 patients in the AI group and 22 patients in the PFS group. Main reasons for withdrawal during this phase were occurrence of AEs/SAEs (n = 8 in AI; n = 5 in PFS) and patient’s request (n = 6 in AI; n = 8 in PFS).

RA has been diagnosed 5.3 ± 6.6 years before entry in the study when patients were 58.9 ± 12.6 years old. At the inclusion visit, MTX treatment was initiated for 3.1 ± 3.3 years; current MTX administration was through subcutaneous route (58.4%) or orally (38.6%). Mean dosage of MTX was 15.4 ± 4.2 mg/week corresponding to a mean dose of 0.22 ± 0.07 mg/kg/week. Thirty-one patients (15.5%) had a current MTX dosage > 0.3 mg/kg/week. Mean DAS28 score was 3.1 ± 1.2. Around one-third of patients were in remission (DAS < 2.6). Mean HAQ score was 0.60 ± 0.60. Around one-third of patients (n = 56; 27.7%) had no impairment (HAQ = 0). Patients characteristics are detailed in Table 1.

Table 1 Patients characteristics

Evolution of the MTX Dose

At visit M0, patients were prescribed a mean MTX dose of 16.5 ± 4.2 mg/week thus a mean of 0.24 ± 0.07 mg/kg/week, which was inferior to 0.3 mg/kg/week in 158 (79.0%) patients. Mean dose of MTX remained stable during the comparative phase, ranging from 16.8 ± 4.2 mg/week at M2 to 16.9 ± 4.4 mg/week at M6 (median dose = 15 mg/week). MTX dose changed at least once during the comparative phase in 22 (21.8%) patients with AI and 16 (15.8%) of those with PFS. Change was mainly due to clinico-biological signs.

Compliance

Compliance during the comparative phase was 96.2 ± 14.6% in the AI group and 98.9 ± 11.4% in the PFS group, thus a non-significant difference (AI–PFS) of − 2.7% (95% CI − 6.4%; 1.0%) in the PP set. Good compliers were 89.9% in the AI group and 94.9% in the PFS group, thus a difference of (AI–PFS) of − 5.0% (95% CI − 18.9%; 8.9%) which was slightly more than the non-inferiority limit of − 4%. Similar results were observed in FAS set (Table 2).

Table 2 Compliance

HAQ Score

HAQ score remained stable, from baseline to M6, in the two groups. In the PP set, HAQ score decreased from 0.66 ± 0.62 to 0.60 ± 0.58 in the AI group and from 0.55 ± 0.58 to 0.49 ± 0.60 in the PFS group. After imputation to 400% of relative change in HAQ in patients with baseline value = 0 and post-baseline value > 0, percentage of HAQ change at the end of comparative phase from baseline was 21.3% (95% CI − 2.6%; 45.2%) in the AI group and 22.4% (95% CI − 1.6%; 46.5%) in the PFS group. Difference of percent change in HAQ score between AI and PFS was − 1.1% (95% CI − 35.0%; 32.7%). The upper limit of the 95% CI of the difference was superior to the non-inferiority limit of 5% but with a high confidence interval due to both missing data for the endpoint and a high variability of the change of HAQ related to imputation rules (Table 3).

Table 3 Clinical evolution at the end of the comparative phase (M6)

Mean absolute change was − 0.06 ± 0.38 in the AI group and − 0.06 ± 0.41 in the PFS group (p = 0.635). Similar results were found in the FAS.

A decrease in HAQ score of − 0.22 is considered as the minimal clinically important improvement (MCII) [21]. Twenty-five (25.3%) patients in the AI group and 30 (30.6%) in the PFS group improved HAQ score by at least − 0.22. On the other hand, HAQ score increased of at least 0.22 in 19 (19.2%) and 17 (17.3%) patients, respectively. Using another threshold of − 0.375 as MCII [22], 15 (15.2%) patients in the AI group and 19 (19.4%) in the PFS group improved HAQ score by at least − 0.375. HAQ score increased of at least 0.375 in 11 (11.1%) and 12 (12.2%) patients, respectively.

RaQoL

Quality of life, assessed by the RaQoL questionnaire, remained stable in both groups during the comparative phase of the study. No significant difference was found between groups (p = 0.886 in the PP set; p = 0.809 in FAS).

DAS28

EULAR good response based in the improvement of the DAS28 score was observed in 25.3 and 23.9% of patients and moderate response was reported on 20.9 and 22.7% of patients from of AI group and PFS group respectively, at the end of the comparative phase.

Acceptability

AI was declared to be not at all or somewhat not stressful by 77.4% of patients, and not at all or somewhat not painful by 72.6% as compared with 66.6 and 69.2% of patients with PFS, respectively. The method of administration was declared to be moderately to very pleasant in 59.4 and 36.8%, reassuring in 91.8 and 88.6%, and easy-to-use in 95.3 and 86.3% of patients in the AI group and the PFS group respectively. Positive judgments translated in a high rate of moderately to very much satisfied patients (96.5%), as compared to a rate of 90.1% of patients in the PFS group. At the end of the comparative phase, patients very or quite motivated to pursue the treatment using the same device represented 83.8% of the AI group and 69.6% of the PFS group. Similar results were found for FAS (data not shown).

At the end of the comparative phase, 93.6% of patients who used a syringe for MTX injection before the study and who were allocated to the AI group preferred auto-injector (p < 0.001). At the end of the non-comparative phase, 96.2% of patients who experienced both methods of injections declared to prefer AI (p < 0.001). Overall, products were well accepted but acceptability was better with AI than with PFS. Differences were significant for treatment-related burden (p = 0.018), pleasantness (p < 0.001), reassurance (p = 0.016), and ease-of-use (p < 0.001). Global satisfaction and willingness to pursue the method of administration was higher for AI than for PFS (p < 0.001 and p = 0.001). No significant difference was observed regarding injection related stress or pain (Fig. 1).

Fig. 1
figure 1

Acceptability. Patients were asked on acceptability at M6 visit using a self-questionnaire with questions answered with a five-point Likert scale. Acceptability encompassed ease of use, satisfaction, pleasantness, motivation for further utilization, reassurance, treatment-related burden, stress during injection, and pain during injection. AI auto-injector, PFS prefilled syringe

Patient Autonomy for MTX Administration

MTX was mainly self-administered: 105 (86.8%) patients in the AI group and 78 (69.6%) patients in the PFS group of the safety set, reflecting higher autonomy with AI. Healthcare professionals were involved in MTX administration for eight (6.6%) patients in the AI group and 22 (19.6%) in the PFS group. Family and friends were involved in the remaining cases: i.e., for seven (5.8%) and 11 (9.8%) patients, respectively (Fig. 2).

Fig. 2
figure 2

MTX administration. At M6, patients were asked on whether MTX was self-administered (green) or administered with the help of healthcare professionals (yellow) or family and friends (orange). AI auto-injector, PFS prefilled syringe

Safety

General tolerance was similar between groups. During the comparative phase, nine patients (6.6%) from the AI group and four patients (3.3%) from the PFS group reported local adverse events at injection site, including, for AI, erythema, hematoma, pain, local reaction, and, for PFS, local swelling and skin depigmentation. Difficulty in using the device was reported by two patients in the AI group; a material issue was reported by one patient in the AI group. Local safety was very satisfactory or satisfactory according to the physician in 95.5 and 95.8% at M2, 96.7 and 100% at M4, and 96.7 and 94.6% at M6 in the AI group and the PFS group, respectively.

One patient from the PFS group died during the study from a metastatic Merkel’s cells carcinoma that was not related to the study product.

Discussion

This study aimed at assessing the feasibility of MTX self-injections using a pre-filled AI. Based on the percentage of good compliers (overall compliance ≥ 80%), the non-inferiority was not demonstrated. Indeed in PP set, the good compliers rate was 89.9% in the AI group and 94.9% in the PFS group, and the difference between groups was − 5.0% (95% CI − 18.9%; 8.9%) for a non-inferiority limit of − 4%. Nevertheless, compliance during the comparative phase was very good: 96.2% in the auto-injector group and 98.9% in the pre-filled syringe injection group. Difference of compliance was − 2.7% (95% CI − 6.4%; 1.0%), a slight difference that did not reach statistical significance. Based on the relative change in HAQ, non-inferiority was not demonstrated. Nevertheless, HAQ score remained stable in the two groups or even slightly improved without difference between groups. A similar proportion of patients experienced a decrease in HAQ at least equal to the minimal clinically important improvement. No difference was found between the two groups on quality of life or evolution of DAS28. Products were well accepted with better patient assessment for AI on treatment-related-burden, pleasantness, reassurance and ease of use. Global satisfaction and willingness to pursue the treatment were higher for AI.

In patients who had the opportunity to use both methods, 93.6% declared to prefer auto-injector at M6 and 96.2% at M12. Self-administration with AI was more frequent than with PFS.

Proportion of MTX injections involving healthcare professionals in the AI group were about threefold lower than the one in the PFS group, suggesting a higher patient autonomy in the AI group. Safety profile including local safety was similar between the groups.

The World Health Organization considers that improving patients’ adherence to long-term therapies is more efficient than any biomedical progress [23]. Non-adherence is not only associated with negative clinical consequences [24] but can also result in substantial healthcare costs. Some authors have highlighted the good usability of SC MTX related to the absence of pain at injection site, a factor contributing to good compliance [25]. According to rheumatologists after a Delphi process, there are three major factors of non-compliance with DMARD: (1) not knowing what to do in the case of an adverse event with DMARD; (2) not having undergone adherence screening by health personnel for early detection of “non-compliant patients”; and (3) not having undergone interventions or strategies that improve adherence [26]. Linn et al. [27] documented explicit and implicit attitudes of RA patients towards MTX. If explicit attitudes were positive and health-related, implicit attitudes were, however, negative and sickness-related. Half of the patients displayed explicitly positive but implicitly negative attitudes. Implicit attitudes had a major impact on compliance. Improved adherence has been associated with belief in the necessity and efficacy of MTX, absence of low mood, mildness of disease, and monotherapy with MTX [28]. Compliance to MTX has been reported to be higher with subcutaneous administration when compared to oral route [11]. This could be due to a lower risk of gastro-intestinal side effects with parenteral MTX [29].

In the SELF-i study, patients compliance to MTX was greater than 95%. In a recent systematic literature review, Sheiman-Elazari et al. [30] reported a mean compliance rate with DMARDs of 66% (95% CI 58%; 75%). SELF-I study’s better results may be due to the context and to the method of assessment. Patients included in a clinical trial are more prone to be compliant with the study drug; they visit their physician on a regular basis, and the importance of compliance is regularly reminded; in addition, clinical trials are generally brief and do not mimic real-life conditions. Patients were asked to bring back their used and unused treatment units at each visit so that the physician could calculate compliance. Many other definitions of compliance have been found in the literature by Sheiman-Elazari et al. [30]. When using the same definition than in the SELF-i study, compliance rates for DMARDs vary from 68% [31] to 87% [32]. Using electronic monitoring systems to record MTX intake (orally or via injection) during 16 weeks, De Cuyper et al. reported that only 58% of patients were fully adherent [33]. We defined good compliers as patients who had administered at least 80% of the prescribed MTX units. The same or approaching definitions have been used by others [34, 35]. Curtiss et al. [36] have conducted a systematic review of 12 studies reporting adherence rate to MTX and observed a great variability among patient’s characteristics, clinical settings, methods of compliance assessment, and adherence rate. Of the current MTX users, Aaltonen et al. reported that 6.8% of patients identified themselves moderately non-adherent to the treatment [37]. As far as we know, compliance to MTX self-injection with a syringe, an AI or any of them has not been specifically evaluated. Consequently, the SELF-I study is one of the first trials addressing the compliance to MTX injection with AI.

The difference between groups in compliance exceeded the non-inferiority threshold that has been set at − 4%. This was a very demanding threshold, largely smaller than usually required. For example, bio-equivalence thresholds are usually (80%; 125%). The difference between groups was very small and certainly of no clinical relevance. As an indirect proof, clinical evolution was similar between groups with no difference on HAQ or change in DAS28. Furthermore, mean overall compliance rates in the two groups were both greater than 95% and were not significantly different [mean difference − 2.9% (− 6.6; 0.7); t test p = 0.1097, in FAS set]. These results suggested that compliance was not impaired when using AI rather than PFS with pre-filled syringes. Only very few patients showed poor compliance (≤ 60%) despite general convenience and ease of use of AI and to a lower extent PFS. Device-related aspects may not be the explanation for this slight and likely non-relevant difference in compliance. Moreover, the high level of satisfaction and acceptability and the good local safety did not jeopardize the compliance and certainly did not threaten adherence in a real-life setting. In addition, the large 95% CI was partly due to a smaller sample size than expected.

The importance of percent change contrasted with the stability of HAQ illustrated by absolute change. Indeed, the variance of the percent change was considerably inflated after imputation of missing data, resulting in a lack of power for comparisons and the large confidence interval of the difference between groups. In this context and for percent change, the study should be considered as non-informative rather than negative since it was not adapted to such variance. HAQ score remained stable during the study. Two definitions of minimal clinically important improvement (MCII) in HAQ score have been proposed [22, 38]. Relying on patients self-assessment against other patients, Redelmeier et al. proposed a value of − 0.22 [38]. On the other hand, relying on patients’ judgment of their current status relative to their previous status, Ward et al. proposed a value of − 0.375 [22]. A similar proportion of patients experienced a decrease in HAQ score reaching MCII in both groups, independent of the definition used.

Local safety was found to be very satisfactory or satisfactory by the physician in 96.7% at M6 in the AI group and in 94.6% in the PFS group. Given that the administered product was the same in the two groups, differences in local tolerance could have resulted from differences in flow rate, regularity of injection or injected volume. MTX concentration is twice lower in the AI than in the prefilled syringe. Consequently, patients had to inject a twice-larger volume to administer the same MTX dose. Volumes remained however very small. The median dose of MTX was 15 mg/week corresponding to 0.6 ml with the AI and 0.3 ml with the syringe. Indeed, patients did not report local adverse events that could be related to the injected volume. Using PFS, patients had to push the plunger of the syringe and therefore were able to adapt the flow rate at their own comfort. Conversely, the flow rate was fixed in the auto-injector group. Despite that, injections with AI were not painful. Furthermore, difficulty in using AI was reported only by two patients, although AI was a new device. As PFS was a well-established method of administration, such events were not collected during the study and no comparison could be made.

Fear of needles or at least discomfort with the idea to prick oneself is a widespread feeling. AI have the advantage of hiding the needle and indeed patients from the AI group found the MTX administration less stressful than when using a syringe. In the AI group, the prick was considered to be quite or very stressful by 8.4% of patients. By contrast, in the PFS group 16.7% of patients reported that the prick was quite or very stressful. AI was found easy to use and contributed to make the treatment less burdensome. It was considered more pleasant than the syringe. As mentioned earlier, concentration of MTX was different between AI and PFS, resulting in a twofold difference in the volume injected for the same MTX amount. It is not known if this feature had a role in the acceptance of the device. Nonetheless, taking in charge the parameter of injection, AI were found more reassuring. Furthermore, less recourse to nurse support for injection and consequently higher proportion of self-injections illustrated better autonomy, which is a key issue in active patients. Acceptability of AI certainly participated in the improvement of patient autonomy. Furthermore, the reduced involvement of nurse and healthcare staff for AI-related injections may result in potential savings of healthcare resources as both devices per se involved similar costs.

In our study, the majority of patients preferred AI over PFS. However, preference could not be assessed in all patients who went through the study, thus constituting a limitation of the study. Forty-three patients (out of the 202 patients of the FAS population) who entered the study in the AI group, without prior experience with PFS could not have been surveyed. One could not rule out that if they had been switched to PFS, their preference would have been different from the other patients.

Conclusions

This study did not demonstrate non-inferiority of AI versus PFS for administration of MTX in RA patients on both compliance and percentage change in HAQ score but compliance was excellent with both devices and HAQ score remained stable in the two groups. In addition, AI was better accepted than PFS, improved autonomy with less healthcare professional resource requirement, and gained patients’ preferences. Therefore, AI is a valuable alternative to PFS for MTX self-injections in RA patients.