Skip to main content

Advertisement

Log in

A new trend to reduce adverse events in patients undergoing transcatheter aortic valve implantation: cusp overlap technique: a cross sectional study

  • Original Article
  • Published:
Aging Clinical and Experimental Research Aims and scope Submit manuscript

Abstract

Background

Transcatheter aortic valve implantation (TAVI) is currently the treatment of choice for the majority of patients at moderate or high surgical risk. However, some complications occur frequently with this procedure. In this study, we aimed to assess whether the cusp-overlap view (COP) technique may be associated with a reduced incidence of some of these complications compared with the classical three-cusp view (TCV) technique.

Methods

In this single-center, retrospective study we investigated; technical success, postprocedural permanent pacemaker implantation (PPMI), new-onset stroke, pericardial tamponade, arrhythmia development, acute renal failure, major bleeding, major vascular complications, procedure-related coronary obstruction, new-onset left bundle branch block (LBBB), paravalvular leak, peri-procedural myocardial infarction (MI), day of hospitalization, death, and major adverse cardiac and cerebrovascular events (MACCE) were determined as the clinical endpoints.

Results

A total of 281 consecutive patients who met the study criteria and underwent elective or emergency transfemoral TAVI using the self-expandable CoreValve Evolut valve were included. 176 consecutive patients implanted with the classical TCV technique and 105 consecutive patients implanted with the COP technique were compared. Compared with the TCV group, patients in the COP group had lower PPMI (3.8% vs. 10.8%, p = 0.039), in-hospital mortality (1.9% vs. 8.5%, p = 0.018), and 1-year death (4.8% versus 18.8%, p = 0.001), and MACCE rates (12.4% vs 31.3%, p < 0.001).

Conclusion

The COP technique may help to reduce the conduction disturbances, PPMI requirement and complication rates that may develop following TAVI. In addition, it is an interesting result that it reduces mortality and MACCE rates in long-term follow-ups.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4

Similar content being viewed by others

Data availability

The data are available from the authors upon reasonable request.

References

  1. Leon MB, Smith CR, Mack MJ et al (2016) Transcatheter or surgical aortic-valve replacement in intermediate-risk patients. N Engl J Med 374:1609–1620

    Article  CAS  Google Scholar 

  2. Popma JJ, Deeb GM, Yakubov SJ et al (2019) Transcatheter aortic-valve replacement with a self-expanding valve in low-risk patients. N Engl J Med 380:1706–1715

    Article  Google Scholar 

  3. Abdel-Wahab M, Landt M, Neumann FJ et al (2020) 5-year outcomes after TAVR with balloon-expandable versus self-expanding valves: results from the CHOICE randomized clinical trial. JACC Cardiovasc Interv 13:1071–1082

    Article  Google Scholar 

  4. Zadrozny M, Hainzer N, Mehilli J et al (2021) TAVR in nonagenarians: an analysis investigating safety, efficacy, symptomatic improvement, and long-term survival. J Cardiol 78:44–50

    Article  Google Scholar 

  5. Sammour Y, Krishnaswamy A, Kumar A et al (2021) Incidence predictors, and implica-tions of permanent pacemaker requirement after transcatheter aortic valve replacement. JACC Cardiovasc Interv 14:115–134

    Article  Google Scholar 

  6. Wong I, Bieliauskas G, De Backer O et al (2021) Technical considerations for transcatheter aortic valve replacement with ACURATE neo2. JACC Cardiovasc Interv 14:224–226

    Article  Google Scholar 

  7. Doldi PM, Stolz L, Escher F et al (2022) Transcatheter aortic valve replacement with the self-expandable core valve evolut prosthesis using the cusp-overlap vs. Tricusp-View J Clin Med 11:1561

    Article  Google Scholar 

  8. Sengupta A, Alexis SL, Lee T et al (2021) Cusp overlap technique: should it become the standard implantation technique for self-expanding valves? Curr Cardiol Rep 23:154

    Article  Google Scholar 

  9. Pascual I, Almendárez M, Avanzas P et al (2022) Cusp-overlapping TAVI technique with a self-expanding device optimizes implantation depth and reduces permanent pacemaker requirement. Rev Esp Cardiol (Engl Ed) 75:412–420

    Article  Google Scholar 

  10. Tang GHL, Zaid S, Michev I et al (2018) “Cusp-overlap” view simplifies fluoroscopy-guided implantation of self-expanding valve in transcatheter aortic valve replacement. JACC Cardiovasc Interv 11:1663–1665

    Article  Google Scholar 

  11. Baumgartner H, Hung J, Bermejo J et al (2009) Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice. J Am Soc Echocardiogr 22:1–23

    Article  Google Scholar 

  12. Lang RM, Badano LP, Mor-Avi V et al (2015) Recommendations for cardiac chamber quantification by echocardiography in adults: an update from the American society of echocardiography and the European association of cardiovascular imaging. J Am Soc Echocardiogr 28:1-39.e14

    Article  Google Scholar 

  13. Généreux P, Piazza N, Alu MC et al (2021) Valve academic research consortium 3: updated endpoint definitions for aortic valve clinical research. Eur Heart J 42:1825–1857

    Article  Google Scholar 

  14. Mehran R, Rao SV, Bhatt DL et al (2011) Standardized bleeding definitions for cardiovascular clinical trials: a consensus report from the bleeding academic research consortium. Circulation 123:2736–2747

    Article  Google Scholar 

  15. Faroux L, Chen S, Muntané-Carol G et al (2020) Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis. Eur Heart J 41:2771–2781

    Article  Google Scholar 

  16. Jilaihawi H, Zhao Z, Du R et al (2019) Minimizing permanent pacemaker following repositionable self-expanding transcatheter aortic valve replacement. JACC Cardiovasc Interv 12:1796–1807

    Article  Google Scholar 

  17. Auffret V, Lefevre T, Van Belle E et al (2017) Temporal trends in transcatheter aortic valve replacement in france: FRANCE 2 to FRANCE TAVI. J Am Coll Cardiol 70:42–55

    Article  Google Scholar 

  18. Mendiz OA, Noč M, Fava CM et al (2021) Impact of cusp-overlap view for TAVR with self-expandable valves on 30-day conduction disturbances. J Interv Cardiol 2021:9991528

    Article  Google Scholar 

Download references

Funding

This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Tuncay Güzel.

Ethics declarations

Conflict of ınterest

The authors declare that there is no conflict of interest.

Compliance with Ethical Standards

This study was performed in line with the principles of the Declaration of Helsinki.

Ethical approval

Approval was granted by the Dicle University Ethics Committee (date and number: 17/03/2022-71).

Informed consent

Informed consent was obtained by patients.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Güzel, T., Demir, M., Aktan, A. et al. A new trend to reduce adverse events in patients undergoing transcatheter aortic valve implantation: cusp overlap technique: a cross sectional study. Aging Clin Exp Res 35, 375–385 (2023). https://doi.org/10.1007/s40520-022-02307-5

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40520-022-02307-5

Keywords

Navigation