Purpose

To investigate the effect of pre-cured and co-cured flowable composite liner on fracture strength and microleakage of primary anterior teeth with extended composite resin restorations.

Methods

In the current in vitro experimental study, the crowns of 54 extracted primary canine teeth were cut 1 mm above the CEJ, and a pulpectomy procedure was performed. The samples were randomly divided into three groups to restore the coronal part up to 4 mm above the CEJ. In group 1, the samples were built up with Filtek Z250 packable composite resin. In group 2 (pre-cure), first, 1 mm of Filtek Z350 XT flowable liner was applied to the sample, and after curing, the restoration process continued using packable composite resin. In group 3 (co-cure), the flowable composite liner was cured while the first layer of packable composite resin was applied; then, the same restorative procedure similar to the other groups was followed. The samples’ cross-sectional area in the fracture strength test was calculated by AutoCAD software. Subsequently, the samples were subjected to a force in a universal testing machine. The samples related to the microleakage experiment were cut vertically, and then, the dye penetration percentage (10% methylene blue) was measured under a stereomicroscope. ANOVA was used to analyze the data.

Results

Mean fracture strength in group 2 was significantly higher than in group 1 (P = 0.016). The microleakage mean in group 3 was significantly lower than in groups 1 (P = 0.000) and 2 (P = 0.026).

Conclusion

The flowable composite liner and its relevant separate curing increased the fracture strength of composite resin restorations. However, less microleakage was reported in the group where the liner was applied as a co-cure.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to F. Z. Kalakijuybari.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Kalakijuybari, F.Z., Pasdar, N., Ahmadi, G. et al. Investigating the impact of flowable composite liner on the fracture strength and microleakage of large composite resin restorations of primary anterior teeth. Eur Arch Paediatr Dent 24, 473–479 (2023). https://doi.org/10.1007/s40368-023-00812-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s40368-023-00812-3

Keywords

Navigation