Introduction

Procalcitonin (PCT), a biomarker for bacterial infection, has been evaluated in adults, but is less well-studied in children. In adult patients with bacterial infections, PCT levels have been shown to rise early in infection and fall rapidly with effective treatment. In clinical practice, PCT levels above a given cut point suggest bacterial infection that requires antibiotic therapy, while levels below a cut point suggest non-bacterial etiologies that may not require antibiotic therapy. Studies have used a PCT cut point of 0.5 μg/L for sepsis and 0.25 μg/L for pneumonia [1,2,3,4,5]. As most studies have been performed in adults, data regarding the clinical utility of PCT in the pediatric population are limited. Therefore, the ideal PCT cut point in children is not clear. The few existing studies that have evaluated PCT in pediatrics used a variety of PCT cut point values (ranging from 0.13 to 1.75 μg/L), and these cut points also varied by the site of infection [6, 7].

One factor complicating clinical use of PCT is the large number of commercial platforms available for measuring PCT levels, which do not always yield comparable results [5, 8,9,10,11,12]. To date, the majority of pediatric PCT studies have utilized the bioMérieux VIDAS® B.R.A.H.M.S. PCT™ assay (Marcy-l’Étoile, France), which, until recently, was the only U.S. Food and Drug Administration (FDA)-approved PCT test to guide antibiotic initiation or de-escalation decisions. In July 2018, the Roche Elecsys® B.R.A.H.M.S. PCT test (Basel, Switzerland) received FDA approval for the same indication. Therefore, we evaluated agreement between the bioMérieux and Roche PCT assays using samples from hospitalized children with possible infection. We sought to determine the bias between assays and how often clinical decision making could be impacted by using one test versus the other.

Methods

Sample Collection, Processing and Procalcitonin Testing

We conducted a single-center cross-sectional study using plasma samples collected from children (less than 19 years of age) presenting to an urban, 267-bed pediatric tertiary care hospital. We included two cohorts of children. Cohort 1 consisted of 142 stored plasma specimens, collected as part of an earlier study from December 2014 through January 2017 from children presenting to the emergency department with clinical and radiographic evidence of community-acquired pneumonia [13]. Subjects were excluded if they met any of the following criteria: (1) alternative non-pneumonia diagnosis, (2) hospitalized within the previous 7 days (including hospital transfers), (3) primary or secondary immunocompromising conditions, (4) presence of tracheostomy, (5) diagnosis of cystic fibrosis, or (6) extended or long-term care facility resident.

Cohort 2 was comprised of an additional 71 stored plasma specimens from children presenting to either the emergency department or the oncology clinic for whom a blood culture was ordered due to concerns for sepsis, and who were prospectively enrolled from November 2017 through June 2018. Subjects were excluded if they met any of the following criteria: (1) neonates younger than 7 days of age, (2) infants who were ultimately admitted to the neonatal intensive care unit, or (3) the participant, parent or guardian did not provide informed consent and/or assent, when appropriate.

Samples for PCT testing for patients in Cohort 1 were collected in a lithium heparin gel tube at the time of study enrollment and refrigerated for a maximum of 12 h prior to centrifugation and storage of plasma at – 80 °C until PCT analysis. Frozen samples were thawed and separated into two aliquots. One aliquot was then run on the bioMérieux platform, while the other aliquot underwent an additional freeze–thaw cycle prior to testing on the Roche platform. For Cohort 2, blood samples were obtained in a lithium heparin gel tube for PCT analysis at the time that their initial blood culture was drawn. These samples were refrigerated within 3 h of collection, centrifuged, separated into two aliquots within 72 h of collection, and the plasma was then frozen at − 80 °C until PCT analysis. Each aliquot was only tested on one platform. Testing generally occurred within 3 months of specimen collection.

Procalcitonin testing was performed using the bioMérieux VIDAS® 3 platform and the Roche Elecsys® BRAHMS PCT reagent on an e411 immunoassay analyzer. The minimum volume of serum required for testing was 0.2 mL on the bioMérieux assay and 0.5 mL for the Roche assay. The reportable range of each assay is 0.05–200 μg/L for the bioMérieux assay and 0.02–100 μg/L for the Roche assay. Aliquots from all samples were tested on both platforms. For both cohorts, treating providers were not aware of the PCT results, which were not reported in the electronic medical record.

Statistical Analyses

Pearson’s correlation, simple linear regression and Bland–Altman plots were used to compare performance of the two PCT platforms. All analyses were performed using R v.3.5 (Boston, MA, USA) or Stata/IC v.15.1 for Mac (College Station, TX, USA). P values < 0.05 were considered statistically significant. We conducted a subgroup analysis comparing values from Cohort 1 and Cohort 2 separately, to account for the additional freeze–thaw cycle that samples from Cohort 1 underwent prior to testing on the Roche platform.

Compliance with Ethics Guidelines

The study procedures were approved by the Vanderbilt University Institutional Review Board, reference number 171094. The study conformed with the Helsinki Declaration of 1964, as revised in 2013, concerning human and animal rights, and Springer’s policy concerning informed consent was followed. Written informed consent for study participation and publication of de-identified results was obtained from the parents or guardians of the children who served as participants in the investigation and, when appropriate, assent from the subjects themselves was obtained.

Results

During the study period, 208 unique patients contributed 213 specimens, with 142 (67%) specimens from Cohort 1 and 71 (33%) specimens from Cohort 2. The median age of the 208 patients was 5.2 years (range 8 days–18.9 years), 157 (74%) were white, 164 (77%) were non-Hispanic or Latino, and 137 (65%) were male.

The Roche and bioMérieux tests displayed excellent correlation across the entire range of PCT concentrations (Pearson’s correlation coefficient 0.95, line of best fit equation y = − 0.27 + 0.64x; Fig. 1a). In our subgroup analysis, there was excellent correlation among PCT values from Cohort 1 (Pearson’s correlation coefficient 0.98, line of best fit equation y = − 0.34 + 0.66x), and good correlation among PCT values from Cohort 2 Pearson’s correlation coefficient 0.78, line of best fit equation y = 0.17 + 0.47x). Platform concordance was better at lower values than at higher values (Fig. 1b, c). The Roche platform resulted in lower PCT values as compared to the bioMérieux platform across the entire range of PCT values, with a mean bias of 0.13 μg/L in the range < 2 μg/L, where accepted cut points for PCT-guided antibiotic treatment decisions lie (Fig. 1b, c). However, this bias did not always lead to a clinically significant difference (i.e., crossing a PCT cut point). That is, only 10 samples (4.7% of 213) had PCT levels that were 0.25 μg/L or higher on the bioMérieux platform, but less than 0.25 μg/L on the Roche platform. Similarly, 16 samples (7.5% of 213) had PCT levels of 0.5 μg/L or higher on the bioMérieux platform, but less than 0.5 μg/L on the Roche platform. One sample was greater than 0.5 μg/L on the Roche platform, but less than 0.5 μg/L on the bioMérieux platform. Overall, this resulted in a total of 27 samples (12.7%) in which the measurement bias would have potentially altered antibiotic therapy decisions.

Fig. 1
figure 1

Comparison of PCT measurement by bioMérieux and Roche Platforms. a Scatterplot of PCT values measured by each platform. Combined data from Cohort 1 and Cohort 2 are shown. Blue line represents regression line and black line represents line of unity. Black triangles represent PCT values from Cohort 1 and red circles represent PCT values from Cohort 2. Graph restricted to values ≤ 100 μg/L for better visualization. b Pair plot of PCT values measured by each platform, restricted to values ≤ 2 μg/L. Each pair represents one patient’s plasma sample. Solid line represents clinically accepted cut point for sepsis, dashed line represents clinically accepted cut point for pneumonia. Asterix represents pair of samples that cross clinically accepted cut points. c Bland–Altman plot of PCT values, restricted to PCT values ≤ 2 μg/L. Horizontal dashed black lines represent the mean of the difference between bioMérieux and Roche values, and the upper and lower limits of the 95% confidence interval. Black triangles represent PCT values from Cohort 1 and red circles represent PCT values from Cohort 2. The mean of the difference is approximately 0.13 μg/L, indicating that the mean PCT measured on the bioMérieux platform is 0.13 μg/L higher than the mean PCT measured on the Roche platform. Vertical solid black lines denote clinically accepted cut points; above 0.5 μg/L suggests bacterial infection is likely, and below 0.25 μg/L suggests bacterial infection is unlikely. PCT procalcitonin

Discussion

In this single-center study using stored specimens from children with possible sepsis or pneumonia, the bioMérieux and Roche PCT tests demonstrated similar results, with excellent concordance, particularly at levels below 2 μg/L where cut points for antibiotic decision making algorithms lie (ranging from 0.13 to 1.75 μg/L in prior studies) [6, 7]. The diagnostic utility of PCT in children with sepsis is unclear, and further studies are warranted to determine whether cut points used in adults also apply to children. The accepted PCT cut point for adults with sepsis of 0.5 μg/L and for adults and children with pneumonia of 0.25 μg/L are well within the range where the platforms demonstrate good agreement [1, 2, 11, 14, 15]. Our data demonstrate that PCT levels within the range of 0–2 μg/L are approximately 0.13 μg/L lower using the Roche test as compared to the bioMérieux test. Although this difference would have only impacted approximately 13% of samples in our study, clinicians should be aware of the potential difference in PCT measurements, especially when a patient is transferred between two institutions that use different PCT platforms. Assays that use the B.R.A.H.M.S. PCT monoclonal antibodies, such as the Roche and bioMérieux assays, are expected to have a high level of concordance, as was seen in this study. Notably, there are other PCT assays entering the market that do not use these antibodies, and it remains uncertain whether these assays will demonstrate the same degree of concordance [10, 16].

Our study has a number of strengths, including a large sample size and comparison of two commonly used and commercially available platforms. However, it also has some limitations. We did not include the gold-standard platform for testing, the BRAHMS PCT Kryptor system (Hennigsdorf, Germany) [10]. Additionally, due to logistical issues, the samples that were stored frozen for longer than 6 months underwent an additional freeze–thaw cycle prior to testing on the Roche platform. It is possible that this additional freeze–thaw cycle impacted the Roche PCT test results and potentially contributed to the observed bias between the two methods, although a prior study demonstrated that repeated freeze–thaw cycles do not have significant influence on measured PCT levels [17]. We used stored samples for PCT measurement, which have been shown to demonstrate a modest decline of approximately 10% after deep-frozen storage for 3–5 years [18]. Our study compared Roche and bioMérieux test results from the same blood sample, so long-term storage of samples should not account for differences between platforms.

Conclusions

We conclude that PCT levels measured on the bioMérieux and Roche platforms are similar, especially at ranges < 2 μg/L, where cut points lie for antibiotic decision-making algorithms. The Roche assay yielded lower PCT values than the bioMérieux assay, producing a bias that would have potentially altered PCT interpretation in a modest percentage of patients. As PCT is increasingly used for patient care, clinicians should be aware that PCT measurements can differ across platforms, although differences appear small and are unlikely to have major clinical impact.