Abstract
This paper presents suction measurements in case of unsaturated soils using a commercially available water potential sensor. The sensor uses ceramic discs of predetermined pore-size distribution (i.e., fixed-matrix) for suction measurement and a surface mounted thermistor to take temperature readings. The ceramic disc assembly of the sensor is brought in contact with a soil for which the suction measurement is required. The sensor measures the water content of the ceramic discs and further uses the water retention characteristic of the ceramic discs to determine suction. The suction thus determined is equal to the suction of the soil which is in contact with the sensor. Soil–water mixtures were prepared from two clays (Speswhite kaolin and MX80 bentonite) with a diversified range of plasticity properties and mineralogy. Suction measurements of the soil–water mixtures were carried out at several water contents. The measured suctions of the clays were compared with the test results from a dew-point potentiameter. The test results showed that, very high suctions up to more than 10,000 kPa and very low suctions up to about 10 kPa can be measured using the sensor. The suction equilibrium time for the soils studied was found to vary between a couple of hours to several days depending upon the magnitude of suction and initial state of the sensor (i.e., wet or dry). Comparisons of the test results from the sensor with the results from the dew-point potentiameter tests showed some significant differences in case of the bentonite, whereas the agreements between the test results from the two devices were better in case of Speswhite kaolin. The test results clearly showed that under predetermined conditions, the water potential sensor can be used to measure soil suction greater than 1500 kPa within a few hours.
Similar content being viewed by others
References
Aitchison GD (ed) (1965) Moisture equilibria and moisture changes in soils beneath covered areas. In: A symposium in print. Butterworths, Australia
Bulut R, Leong EC (2008) Indirect measurement of suction. Geotech Geol Eng 26(6):633–644
Decagon Devices (2014) Commercial publications, operator’s manual for MPS-2 & MPS-6 dielectric water potential sensors. Decagon Devices, Inc., Pullman www.decagon.com
Delage P, Romero E, Tarantino A (2008) Recent developments in the techniques of controlling and measuring suction in unsaturated soils. In: Unsaturated soils: advances in geo-engineering, Toll DG et al. (eds), Routledge, London, pp. 33–52. Proceedings of the first European conference on unsaturated soils, E-UNSAT, Durham, UK
Fleureau J-M, Kheirbek-Saoud S, Soemitro R, Taibi S (1993) Behavior of clayey soils on drying-wetting paths. Can Geotech J 30(2):287–296
Fredlund DG, Rahardjo H, Fredlund MD (2012) Unsaturated Soil Mechanics in Engineering Practice. Wiley, New York
Krahn J, Fredlund DG (1972) On total, matric and osmotic suction. J Soil Sci 114(5):339–348
Leong EC, Tripathy S, Rahardjo H (2003) Total suction measurement of unsaturated soils with a device using the chilled-mirror dew-point technique. Géotechnique 53(2):173–182
Tang AM, Cui YJ (2005) Controlling suction by vapor equilibrium technique at different temperatures, Application in determining the water retention properties of MX80 clay. Can Geotech J 42(1):287–296
Tripathy S, Elgabu H, Thomas HR (2012) Matric suction measurement of unsaturated soils with null-type axis-translation technique. Geotech Test J 35(1):91–102
Tripathy S, Rees SW (2013) Suction of some polyethylene glycols commonly used for unsaturated soil testing. Geotech Test J 36(5):768–780
Tripathy S, Tadza MYM, Thomas HR (2014) Soil–water characteristic curves of clays. Can Geotech J 51(8):869–883
van Genuchten MTh (1980) A closed-form equation for predicting the hydraulic conductivity of unsaturated soils. Soil Sci Soc Am J 44:892–898
Vanapalli SK, Sillers WS, Fredlund MD (1998) The meaning and relevance of residual state to unsaturated soils. In: Proceedings of the 51st Canadian Geotechnical Conference, Edmonton, Alta., Canada, October 4–7, pp. 1–8
Acknowledgments
The Visiting International Professor grant received from Research School PLUS, Ruhr University Bochum, Germany is gratefully acknowledged. The first author acknowledges the financial support provided by the Welsh Government and Higher Education Funding Council for Wales through the Sêr Cymru National Research Network for Low Carbon, Energy and Environment. The writers are grateful to Mr. Ian Coates, Labcell Ltd., UK and Dr. Doug R. Cobos, Decagon Devices, Inc., US, for the helpful discussions related to the water potential sensor used in this study. The authors are grateful to Mr. Xinwei Guo, B. Eng. student at Cardiff University and Mr. Jeison Fabiano Vieira, Students Without Boarder (SWB) student from Brazil for carrying out some initial tests using the water potential sensors.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Tripathy, S., Al-Khyat, S., Cleall, P.J. et al. Soil Suction Measurement of Unsaturated Soils with a Sensor Using Fixed-Matrix Porous Ceramic Discs. Indian Geotech J 46, 252–260 (2016). https://doi.org/10.1007/s40098-016-0200-z