Introduction

Titanium aluminum nitride (TiAlN) is a refractory and very hard material. Due to its physical and chemical properties, from high-temperature resistance to corrosion resistance, it is widely used for coating in high-temperature technologies [1]. TiAlN consists of titanium and aluminum and has the following advantages over titanium nitride:

(1) Oxidation resistance at high temperatures (800–900 °C) due to the formation of the protective aluminum oxide layer; (2) higher hardness (3000 HV); and (3) lower electrical and thermal conductivity [1,2,3].

TiAlN coatings have wurtzite structure at a high-Al portion over Ti, while they are in the form of B1-NaCl at a high-Ti portion over Al (Fig. 1).

Fig. 1
figure 1

TiAlN lattice structure for a B1-NaCl and b wurtzite

TiAlN nanoparticles have been deposited by different methods among which are physical vapor deposition (PVD) [4,5,6], sputtering [7, 8], chemical vapor deposition (CVD) [9], and laser/sol–gel method [10]. TiAlN nanoparticles have also been formed by other plasma focus devices with different energies and configurations [11, 12].

In this study, the plasma focus device of Tabriz Sahand University of Technology was employed to grow TiAlN nanoparticles on stainless steel sub-layer. The nanoparticles were formed on the stainless steel with different numbers of shots. The synthesized samples were examined for their structure by XRD, in surface morphology by SEM, in elements dispersion on the sub-layer by mapping analysis, in topography and surface thickness by AFM, and in grown elements combination on the sub-layer by EDX.

Methodology

A Mather-type plasma focus device of Tabriz Sahand University of Technology consisted of a copper anode electrode with 1.8 cm of diameter and 5.3 cm of length, surrounded by six bronze cathode electrodes, each with 5.3 cm of length. A Pyrex insulator has separated the electrodes (Fig. 2). In this experiment, the anode was made of Ti and Al. There was a shutter between the anode electrode and the sample holder for the initial shots to achieve an excellent pinch. The entire set of the electrodes was placed inside a vacuum container that was pressure-dropped by a rotary compressor to 0.2 torr. Then, a mixture of N2 and Ar gases was injected inside the vacuum container as the working gas.

Fig. 2
figure 2

Schematic of Mather-type plasma focus device

The optimum pressure for the excellent pinch in the experiment was 0.2 torr at 6 kV of voltage. The voltage wave form versus current at pinch time, which was received from Rogowski coil, was recorded by an oscilloscope (Fig. 3).

Fig. 3
figure 3

Rogowski coil current derivative signal at pinch time

For the operation of the plasma focus device, a high voltage was applied between two anode and cathode electrodes by three 10 μF capacitors charged by a high voltage. Then, an electrical discharge took place on the insulator surface in 100 ns, creating a current layer on the insulator surface. A self-consistent magnetic field is created, producing Lorentz force and accelerating the current layer to the open end of the anode. As a result, the J × B force compressed the current layer on the anode, which created warm dense plasma. At this time, the plasma column created by the sausage instability (m = 0) was eliminated by the production of high-energy electron, ion, and X-ray particles. Since a strong magnetic field was created when the plasma column was eliminated, this magnetic field accelerated the ions and electrons in opposite directions such that the high-energy electrons collided with the anode (Ti, Al) and resulted in their melt. Ti and Al atoms were mixed with the ionized N2 gas and deposited on the sub-layer at the pinch time by the produced plasma jet (Fig. 4). Before the formation of the nanoparticles, steel samples were cleaned with alcohol, acetone, and distilled water, each for 20 min in an ultrasonic device with the help of ultrasonic waves.

Fig. 4
figure 4

Dynamics of the plasma focus device

The samples were placed 5 cm above the anode. (Ti, Al)N nanoparticles were also placed at 0° with respect to the anode axis with 100, 150, and 200 shots, being analyzed by XRD, SEM, AFM, EDX, and mapping devices.

X-ray spectroscopy results

The XRD spectroscopy of the samples was done using a grazing technique which is specific to thin layers and coatings. Figure 5 represents the X-ray diffraction spectrum of the synthesized samples with different shots. The diffraction spectrum shows the formation of the TiAlN crystalline phase for the samples grown on steel. Different peaks of TiAlN crystalline planes were observed at 2θ of 44.3°, 51.9°, and 75.6° along with Al2O3 at 45.7°. The diffraction peak locations are matched with the standard data for TiAlN. Hence, the patterns indicate the growth of TiAlN crystals on steel.

Fig. 5
figure 5

X-ray diffraction spectrum for the samples synthesized with a 100 shots, b 150 shots, and c 200 shots

The average size of TiAN was measured by Scherrer’s formula in Eq. 1, where λ is a wavelength of Cu Kα radiation 0.154 nm, D is the size of the crystal, β is FWHM, and K is the Scherrer constant, which in this case was 0.9. From this formula, the average particle size of 100, 150 and 200 shots is 47, 52 and 100 nm, respectively

$$d = \frac{0.9\lambda }{\beta \cos \theta }$$
(1)

SEM results

Figure 6 demonstrates the SEM images for TiAlN nanoparticles on the steel sub-layer. These particles are almost uniformly distributed on the surface. As it is observed, the increased number of the shots increased the deposition on the sub-layer, with the particles starting to join together. The size of the nanoparticles has been increased at 200 shots, which can be attributed to the increased surface energy due to the increased shot number and deposition.

Fig. 6
figure 6

SEM images at a 100 shots, b 150 shots, c 200 shots

AFM results

To measure roughness of the surface of the samples, a microscope of atomic force is used in noncontact state. The AFM images show that the number of the shots is increased from 100 to 200 and the nanoparticles size is increased from 40 ± 10 nm to 90 ± 10 nm which is corresponded with the XRD results. The mean surface thickness was 188 nm at 100 shots, which was increased to 359 nm as the number of the shots increased to 200. This can be due to the increased energy of the ions passed toward the sub-layer (Fig. 7).

Fig. 7
figure 7

AFM images for the nanoparticles grown at a 100 shots, b 150 shots, and c 200 shots

EDX results

EDX analysis was employed to identify the elements constituting the samples. Figure 8 shows the weight percentage graph of the elements grown on the sub-layer at different numbers of shots. EDX results indicate that an increase in the number of the shots affects TiAlN grown on the sub-layer—i.e., it increases TiAlN deposition. At 100 shots, a high content of TiAlN atoms does not have sufficient energy to reach the sub-layer and grow on it due to their high weights and low velocities. Another reason is that the atoms separated from the anode surface are conically dispersed when the focus collapses and the number of TiAlN atoms getting vertically close to the sub-layer is decreased.

Fig. 8
figure 8

Atomic weight graph of the elements deposited on the sub-layer at a 100, b 150, and c 200 shots

Mapping results

This analysis was performed to measure the uniformity of the thin layer and investigate the dispersion of the elements on the sub-layer by SEM, in which the locations of the deposited atoms on the sub-layer are indicated by the device. Figure 9 represents Ti, Al, and N atoms on the steel sub-layer. Mapping results show TiAlN deposition as uniform on the sub-layer.

Fig. 9
figure 9

Layer elements dispersion

Microhardness results

Microhardness is a mechanical property of thin layers, which relates to tensile strength. In this method, a square pyramid penetrator with 136° of apex angle is used. The penetrator penetrates in the sample surface with a given force and makes a rectangular sign with the diameters of d1 and d2 (Fig. 10). Vickers hardness number (DPH) is calculated as force/penetrated area. The penetrated area is calculated from microscopic lengths and diameters. Thus, we have

$${\text{DPH}} = \frac{{2P\sin \left( {\frac{\theta }{2}} \right)}}{{L^{2} }} = \frac{1.854P}{{L^{2} }}$$
(2)

where P is the force in kg, L is the mean length of the diameters in mm, and θ is the pyramid apex angle (i.e., 136°). Given the microhardness results, the hardness of the samples deposited at 100, 150, and 200 shots was 243, 260, and 286 VH, respectively.

Fig. 10
figure 10

Schematic of Vickers hardness

Conclusion

  1. 1.

    TiAlN nanoparticles were grown on 316 stainless steel sub-layer using a 1.5-kJ Mather-type plasma focus device.

  2. 2.

    XRD results indicated the formation of TiAlN structure on the sample surfaces, which is matched with the standard data for TiAlN.

  3. 3.

    According to SEM images and EDX analysis, an increase in the number of the shots resulted in a higher deposition on the sub-layer, increasing the size of the nanoparticles.

  4. 4.

    According to AFM images, the mean surface thickness is increased as the shots increase in number.

  5. 5.

    According to the microhardness results, the increased number of the shots increased the hardness of the deposited samples from 243 to 286 VH.