Introduction

The expression ‘plasma’ indicates a quasi-neutral ionized gas, composed initially of free electrons, ions and ground- or excited-state atoms. Furthermore, the comprehensive components of plasma exist in a net neutral charge [1]. However, plasma is the fourth state of matter and forms more than 99% of the universe. Plasma consists of active particles (e.g., electrons, ions and photons), reactive species (e.g., free radicals) and temporary fields (e.g., heat, acoustic wave, electromagnetic fields). Thus, plasma is a very complicated and active medium. In plasma applications like treating biological materials, plasma components work harmonically. This phenomenon has the appropriate effect on materials in contact with the plasma. However, according to the thermodynamic equilibrium between electrons and ions, plasma can be divided into two categories, thermal and nonthermal plasma. In the case of cold plasma, the electron temperature (Te) is much higher than the global gas temperature (Te ≫ Tg) and the constituting ions, but, being Te \( \approx \) Tg with concerning hot plasma, this is the reason for the terms equilibrium and non-equilibrium plasma are referred to hot and cold plasma, respectively.

Nonthermal plasma has drawn enormous attention because of their common potentials for biomedical applications like sterilization, bio-decontamination and cancer handling [2,3,4,5,6]. Moreover, nonthermal (cold) plasma is an ionized gas generated under atmospheric or low-pressure conditions. At atmospheric or low pressures, nonthermal plasma can be induced and sustained using an electric discharge in a gas, using various methods such as the corona, dielectric barrier discharge, or the gliding arc discharge configurations. The generation of a stable plasma plume is considered as an important feature of cold atmospheric pressure plasma jet (CAPPJ) [7]. Many researchers have been studied the effect of cold atmospheric pressure plasma on the thermally sensitive materials using different plasma jet devices [8,9,10]. CAPPJ has been used in inactivation or death bacteria [11], cancer cells [12, 13], fungi [14, 15], spores [16], parasites [17], phages and viruses [18, 19].

The main importance of cold atmospheric plasma is the ability to generate reactive oxygen species (ROS) and reactive nitrogen species (RNS). Furthermore, these species are considered as active biological agents. On the other hand, the temperature of these species can be saved at room temperature. Moreover, CAPPJ has become a novel and safe technology to use for biological applications [20]. The design of a plasma device, gas type, applied voltage, operation time and air conditions play an essential role in the reactive species type and its concentration [21].

After Gram-negative bacteria were exposed to the nonthermal plasma, the cell wall and the outer membrane have been destroyed, a decrease in ATP intracellular and leakage of nucleic acid and protein from the cells of bacteria [22]. Most of the inactivation bacteria impacts regarding nonthermal plasma are attributed to the production of reactive oxygen and nitrogen species (RONS). Recent evidence recommends that RONS are essential agents in antimicrobial and anti-parasitic drugs, tumor medications and wound healing [23]. Therefore, cold atmospheric pressure plasma as a generator of RONS has high promise to be utilized successfully in these vital fields. RONS has a direct influence on the membrane and cell wall of microorganisms. ROS triggers an oxidative stress response leading to lipid peroxidation [24], inactivation of Fe-S-dependent dehydratases, inactivation of mononuclear iron proteins and DNA damage, which ultimately cause detrimental oxidative cell damage [25].

RONS generated by CAPPJ plays a significant role in wound healing, inactivation of microorganism, tumor medication and cardiovascular therapies. Previous research has shown that RONS has a therapeutic role in addition to their destructive role in living cells. On the other hand, it is being necessary for the immune system and serves as signaling molecules [22]. Moreover, the concentration of RONS must remain balanced in the biological systems. There is no doubt that CAPPJ affects this balance by generating a free radical at the treatment site, so that adjustment of the RONS concentration, plasma dose and exposure time are essential condition for the success of using plasma in many applications. Another advantage of cold atmospheric pressure plasma is the control of plasma dose according to the type of application. A low dose of CAPP can achieve the inactivation of bacteria while not damaging mammalian cells. On the other hand, a medium dose of CAPP can be used for wound healing, cell proliferation, growth factor release and apoptosis in cancer. Furthermore, mammalian cell death and necrosis can be operated at a high dose of CAPP. The principal aim of this work is to investigate the impacts of a helium cold atmospheric pressure plasma jet (HCAPPJ) on bacterial decontamination. This study compared the inactivation of HCAPPJ against E. coli and Staphylococcus aureus as an example for Gram-negative and Gram-positive bacteria, respectively.

Materials and methods

In the current study, the helium cold atmospheric pressure plasma jet (HCAPPJ) system was designed and used in bacteria inactivation. The HCAPPJ is mainly composed of a commercial neon power supply, voltage controller, stainless steel electrodes, dielectrics and helium gas. The design of the CAPPJ as can be seen in Fig. 1 was described in an earlier study [26,27,28]. The high-voltage power supply is a commercially available transformer for neon light. The neon power supply is appropriated in the cold atmospheric plasma to produce the plasma jet to cut the overall cost of the system by substituting the expensive RF power supply which representing the major cost. The output of the high-voltage neon power supply is 30 mA, 10 kV, and 20 kHz, which lie in the range of very depressed frequency of RF. This power supply has an overload, open circuit, earth leakage and short-circuit protection. The input of this power supply is connected to 220 V, 12 A voltage controller. The voltage controller regulates the primary voltage of the high-voltage transformer. The electrode system of the HCAPPJ made up of two parallel stainless steel disks detached by Teflon insulator. The external electrode and the inside electrode have represented the cathode and the anode, respectively. However, the cathode and the anode have similar thickness and diameter of 15 mm and 2 mm, respectively, but the Teflon disk has a 1 mm thickness and 15 mm in diameter.

Fig. 1
figure 1

Cold atmospheric pressure plasma jet system

The two electrodes and Teflon disk have center hole of 1 mm and 1.2 mm diameter, respectively, though center hole helium gas is flowing. The gas flow system is liable for transporting the gas to the plasma jet at the convenient flow rate. It is composed of the gas storage cylinder, binary-stage gas flow controller and gas connection rubber hose. In this work, helium gas with a commercial grade of 99.998% was used to operate the plasma jet system. The helium flow rate was controlled by the binary-stage gas flow controller. Once the helium gas is introduced through the two electrodes and the suitable high voltage is applied between them, the helium atoms are ionized by driving off electrons so that the ionization of neighboring helium species occurred by a collision with free electrons. After the series of these reactions, the helium gas converts to the plasma state.

An optical emission spectrometer detects photon emission in this region. Spectra obtained provide valuable information about species present within the plasma and their electron excitation, which in turn enables the calculation of vibrational and electron temperature within the plasma. The UV–visible emission spectra from the plasma reactor were obtained with a spectrometer which consists of a lens connected to a detector via fiber optic cable. In this work, the spectroscopy with the model number of HR4000CG-UV-NIR (Ocean Optics) was employed. The spectra were registered in the longitudinal geometry with the device probe in an axial position, at a distance of 10 mm from the nozzle outlet with an acquisition time of 1 s. However, the voltage measurement was taken using a high-voltage probe P6015 Tektronix HV probe with a digital oscilloscope (Tektronix MSO4032).

The Reynolds number (Rn) is defined for many various conditions in which a fluid is in relative motion to the interior surface of the tube. The Reynolds number in a tube is commonly represented as the subsequent equation [29, 30],

$$ R_{\text{n}} = \frac{\nu \rho D}{\mu } = 2.2 \times 10^{ - 2} \frac{\rho }{\mu } \frac{Q}{{r_{\text{D}} }} $$
(1)

where ν is the fluid velocity (m/s), ρ is the fluid density (kg/m3), D is the diameter (m) of the tube, and μ is the viscosity (kg/m.s).

However, the fluid velocity can be determined by the following equation,

$$ \nu = \frac{q}{A} $$
(2)

where q is the flow rate in units of m3/s, and the following equation calculated the tube cross section,

$$ A = \pi \left( {\frac{D}{2}} \right)^{2} $$
(3)

The fluid velocity is calculated by the following equation,

$$ \nu = 2.12 \times 10^{1} \left( {\frac{Q}{{r_{\text{D}}^{2} }}} \right) $$
(4)

where Q is the volumetric flow rate in liters per minute (lpm) and rD is an inner diameter in (mm)

In this experiment to study the impact of HCAPPJ on inactivation microorganism, Staphylococcus aureus and Escherichia coli were used. Several colonies were picked up from an overnight culture of each isolate, suspended into 3 ml of brain heart infusion broth (BHI), and then kept for 24 h at 37 °C. However, after 24 h of incubation, the bacterial suspension was diluted with the sterile physiological solution to 5 × 108 CFU/ml, which was compared with 0.5 McFarland standard tubes. After the suspension was prepared, 0.1 ml of this suspension, containing 5 × 108 CFU/ml bacteria, was spread on the nutrient agar via the spreading method by a sterile swab in a standard Petri dish. The dishes were stored in an aseptic location to dry for 10 min and then exposed to the plasma jet.

After the plasma treatment, the samples were put into test tubes containing 5 mL of germ-free water and mixed for 5 min by a vortex mixer. The obtained suspensions were then serially diluted and dispersed onto agar plates, and the CUF number was counted after incubation for 36 h at 37 ± C. In this work, two independent kits of specimens were prepared, and each dilution was dispersed onto two agar dishes, which indicates that each colony counting result was an average of the four agar dishes [31].

Result and discussions

In this work, to determine the optimum conditions to use the HCAPPJ in biological applications a thermocouple was used to determine the plasma temperature. The effect of the distance from the jet nozzle, the helium flow rate and the applied voltage on the plasma temperatures was examined. The effect of the distance from the jet nozzle on the plasma temperatures at 3.5 kV and 14 l/min as a constant applied voltage and constant helium flow rate, respectively, can be seen in Fig. 2. As was expected, the plasma temperature decreases continuously by increasing the axial position. However, the gas temperatures of the plasma jet at different helium flow rates at 3.5 kV and 7 mm as a constant applied voltage and constant distance from the jet nozzle, respectively, can be shown in Fig. 3. From this figure, the gas temperature decreases continuously as the flow rate of helium increases from 10 l/min to 16 l/min. On the other hand, the effect of the applied voltage on the plasma temperatures at 7 mm and 14 l/min as a constant of the distance from the jet nozzle and constant helium flow rate, respectively, can be illustrated in Fig. 4. However, from this figure, the increase in the applied voltage to the carrier gas will produce an increase in ionizing rate, which will lead to a higher gas temperature [32].

Fig. 2
figure 2

The plasma jet temperature at different distances from jet nozzle

Fig. 3
figure 3

The plasma jet temperature at different helium flow rates

Fig. 4
figure 4

The plasma jet temperature at different input voltages

By increasing the input voltage, the higher ion current increases which led to the increase in temperature of gas plasma so that plasma temperature can be controlled by varying the applied voltage which applied to the gas between the two electrodes. Plasma temperature decreases to near room temperature when the gas flow rate increases [33]. However, the helium plasma plume entirely depends on the high flow rates of feed gas to help reduce the gas temperature. Furthermore, it was evident that the current plasma has a low temperature near the nozzle at the most discharge conditions concerning DC plasma plume using the same electrodes design. The DC plasma produces higher gas temperature near the jet nozzle because the cathode heat occurred by the continuous high ion current [34]. Moreover, cold atmospheric plasma can be used in sensitive surface treatment by choosing suitable conditions.

Furthermore, the gas temperature of nonthermal plasma depends on: (1) the input voltage which applied between cathode and anode, (2) the distance from the nozzle and (3) the gas flow rate. The region near the plasma nozzle is an ideal area for treating biological cells because it contains a high concentration of reactive species and the low plasma temperature, resulting in effective nondestructive treatment [35, 36]. Furthermore, the gas temperature increases continuously for all conditions by increasing the operation time.

The plume plasma of HCAPPJ was observed by Ocean optical emission spectroscopy to investigate the behavior of atomic and molecular helium and other constituent species. The optical emission spectrum of the helium plasma jet at 3.5 kV, 14 L/m and 7 mm, which represented applied voltage, helium flow rate and distance from nozzle, respectively, is illustrated in Fig. 5. In this figure, the active species of OH, OII, OI, N21+, N21+ and He are indented in the UV–Vis wavelength range. The interaction between the helium plasma jet and the surrounding air leads to form these active species [37].

Fig. 5
figure 5

Emission spectra from 200 to 900 nm corresponding to 14 l/min, 3.5 kV and 7 mm as helium flow rate, the applied voltage and distance from the jet nozzle, respectively

From this figure, it can be observed that there is no obvious UV emission between 200 nm and 300 nm. The disappearance of these peaks infers that the UV radiation did not contribute to the inactivation process and did not share in any damage which will be caused to the cells of bacteria using this jet. The spectral lines of the hydroxyl group and nitrogen second positive system can be found in the UV region only. Typically, the emission lines at wavelengths 391 and 354 nm correspond to OH and N22+, respectively. However, the spectral lines of OII only can be found in the UV–Vis region, this reactive species can be observed at 337, 406 and 459 nm. Moreover, the reactive species of N21+, OI and He can be found in the Vis region only. The reactive atomic oxygen OI can be detected at 645 and 777 nm [38, 39]. The 580, 654 and 677 nm observed peaks are represented in the N2 first positive system (N21+) [38, 40]. Besides, the reactive species of He can be found at 587 and 706 nm.

The change in the intensity peaks of OH, OII, OI, N21+, N21+ and He species by varying the applied voltage, the distance from the nozzle and the helium flow rate was examined. The change in the intensity peaks of reactive species by varying the distance from the jet nozzle at 3.5 kV and 14 l/min as a constant applied voltage and constant helium flow rate, respectively, is represented in Fig. 6. From this figure, it can be shown that as the distance from the nozzle increased, the spectral line intensities of five species decreased. These results agree with the result obtained by Mashayekh et al. 2015; they concluded that, by increasing the distance from the nozzle, the active species radicals will be recombined and their concentration will diminish with distance [32]. However, from Fig. 7, the intensity peaks of reactive species increase by increasing the applied voltage at 7 mm and 14 l/min as a constant of the distance from the jet nozzle and constant helium flow rate, respectively. This behavior can be attributed to the effect of increasing the applied voltage leading to enhanced discharge current by creating higher reactive species concentrations when more intense ionization wave enters inside the plasma plume [41].

Fig. 6
figure 6

Emission intensities of a OH, O I, O II, N2+1, He and N2+2 as a function of distance from nozzle

Fig. 7
figure 7

Emission intensities of a OH, O I, O II, N2+1, He and N2+2 as a function of applied voltage

On the other hand, from Fig. 8, the intensity peaks of reactive species increase as the helium flow rate is increased at 3.5 kV and 7 mm as a constant applied voltage and constant distance from the jet nozzle, respectively. This behavior can be attributed to the decrease in air concentration, which lies in the plasma region by increasing helium flow rate. The lower air concentration can lead to higher local electron concentration. These explain the higher emission intensity from the excited species [42, 43]. As observed from this figure, the intensity peaks have reached the maximum at 14 l/min, and then, the drop of intensity has occurred after that. These results can be attributed to the effect of Reynolds number. If the Rn is relatively small, such as Rn < 2000, the flow is laminar. If it is large, i.e., Rn > 4000, the flow is turbulent [44]. In this experiment at 16 l/min, the Rn is 4125, and this causes the flow rate to become turbulent and results in instabilities and deformations of the gas flow rate. However, it can be concluded that the decrease in reactive species intensity can be attributed to the deformations, which have been occurred in the gas flow rate.

Fig. 8
figure 8

Emission intensities of a OH, O I, O II, N2+1, He and N2+2 as a function of helium flow rate

Reactive species, which was generated by nonthermal plasma, play an essential role in cell death of microorganism [45]. These reactive species are such as ozone (O3), atomic oxygen (O), superoxide (O2), hydroxyl radicals (OH), nitric oxide (NO), hydrogen peroxide (H2O2), and other reactive molecules, all of which are known to have bactericidal effects [46]. The particles listed above attack the bacterial structure in various ways. Reactive species such as atomic oxygen and OH physically etch the outer cell capsule, thus exposing the cellular membrane [47]. Nonthermal plasma-induced radicals also attack the unsaturated fatty acids transported by the phospholipid bilayer, which are susceptible to attack by most reactive species [48]. Oxidation of the protein content of cellular components, by atomic oxygen, OH, or O2 alters their structure and causes functional changes that may disrupt cell metabolism, preventing necessary protein replication and hence stunting cellular metabolism [49].

Through this work, the optimum conditions of inactivation bacteria using HCAPPJ have been determined. The optimum conditions were obtained by study of helium cold plasma characterization. The irradiation time of helium atmospheric plasma to the same kinds of bacteria was 60 s. At these conditions, the high concentration of reactive species can be obtained; also, we can avoid the hyperthermia effect. Moreover, the first mechanism by which tissue is thermally affected can be attributed to conformational changes of molecules. These effects, accompanied by bond destruction and membrane alterations, are summarized in the single term ranging from approximately 42 to 50 °C [50]. The treatment temperature in this work was in the range of 26–36 °C. From this result, it can be observed that the survival amounts of the two bacteria decrease vastly when the rate flow rate equals 10 l/min, as can be seen in Fig. 9, which means the numbers of alive cells decrease rapidly in the two samples.

Fig. 9
figure 9

The effect of HCAPPJ on No. 1: S. aureus and No. 2: E. coli

Table 1 shows the effect of flow rate of helium at 3.5 kV as applied voltage and 7 mm as a distance from the nozzle on the number of survivors for the two types of bacteria. Further, as the flow rate increases, this led to the decrease in numbers of alive cells decrease. The maximum decrease in alive cells has been recorded at 14 l/min. The higher value of reactive species at 14 l/min of atmospheric helium plasma can be interpreted by the decrease in alive cells. On the other hand, the numbers of alive cells increase at 16 l/min of the helium atmospheric plasma flow rate. The bactericidal effects occur when the particular reactive molecules are present in high concentrations.

Table 1 The survivors number of E. coli and S. aureus as a function of helium flow rate

In low concentrations, most of the reactive species have beneficial effects on the cell functionality, e.g., inhibiting peroxidation or neutralization of other reactive components [51]. Reactive species either reacted with the cell envelope or damaged intracellular components. Gram negative was inactivated by cell envelope damage-induced leakage, while Gram positive was mainly eliminated by intracellular damage [52]. The results obtained show that HCAPPJ is more effective against Gram-negative than Gram-positive bacteria. The differences in cell wall structure can be critical for the differential sensitivity of Gram-negative and Gram-positive bacteria. The structure of the cell envelope concerning Gram-negative bacteria consists of a thin layer of peptidoglycan and lipopolysaccharide, while in the case of a Gram positive the cell envelope consists of a thick rigid layer of peptidoglycan. However, these differences in the cell envelope confer different properties to the cell, in particular response to external stresses, including heat, UV radiation and antibiotics [53]. That means, HCAPPJ induced biological effects which are cell-/bacteria-type dependency [54].

Conclusions

A helium cold atmospheric pressure plasma jet (HCAPPJ) was designed and operated to study the effect of nonthermal plasma on bacteria inactivation. This design exhibits many advantageous features, including i) the production of a large amount of reactive species, ii) operate at low temperature and iii) a simple design and operation. To study the effects of HCAPPJ on bacteria inactivation, initially, the plasma temperature was measured to make sure that the used cold atmospheric pressure plasma jet is safe and has powerful impacts. This measurement is essential and required in the biological application. The plasma temperature and the concentration reactive species depend on the applied voltage, the distance from the nozzle and the helium flow rate. The concentration of reactive species increased by increasing the flow rate from 10 to 14 l/min, and the decrease in the reactive species concentration has occurred when this value is exceeded. The bacteria exposed to plasma showed a decrease in the survival amounts of the two types of bacteria with increasing flow rate of helium gas, suggesting that the RONS played a significant role in the inactivation process. The result revealed that HCAPPJ has more effective against Gram-negative than Gram-positive bacteria. The optimum condition of our HCAPPJ system to bacteria inactivation is 14 l/min, 3/5 kV and 7 mm, which represent the helium flow rate as the applied voltage and the distance from the nozzle, respectively.