Housing in Egypt consumes high energy for cooling. Bioclimatic building design is one of the strategies of sustainable development. This study aims to investigate the thermal performance and indoor air quality of solar chimney with passive cooling wind tower (SCPCW) on occupant’s comfort. Thermal performance of a full-scale SCPCW was experimentally investigated. The passive cooling design is integrated on the ceiling of 30 m2 test house. Monitoring of indoor environment was carried out over a period of 2 months in the summer season (August, September and early October) with a 2-min interval in order to calculate thermal comfort sensation, Predicted Mean Vote (PMV) and Predicted Percentage of Dissatisfied. The results show that outlet air temperature from the wind tower is 27.3 °C. Also, the calculated PMV is within the recommended range (− 0.5 < PMV < + 0.5). This indicates that occupants remain satisfied with indoor thermal environment after using the passive cooling system and the temperature difference between outdoor and indoor is approximately 8 °C. The system achieves the acceptable air flow rate with average 450 ppm for CO2 concentration during daytime. The results of this research provide information of the system applicability in the climate of Assiut during daytime in order to develop and install on top of real residential buildings in New Assiut, Egypt.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10

Similar content being viewed by others

References

  • Abdallah A (2015) The influence of urban geometry on thermal comfort and energy consumption in residential building of hot arid climate, Assiut, Egypt. Procedia Eng 121:158–166

    Article  Google Scholar 

  • Abdallah A (2016) Thermal performance and experimental study of solar chimneys integrated into a room in Assiut University, Egypt. In: 6th international conference on energy research and development, State of Kuwait

  • Abdallah A (2017) Experimental study of passive air condition system integrated into a single room in Assiut, Egypt. Energy Build 153:564–570

    Article  Google Scholar 

  • Abdallah A, Yoshino H, Tomonobu G, Enteria N, Abdelsamei Eid M, Radwan M (2013a) Analysis of thermal comfort for indoor environment of the new Assiut housing in Egypt. World Acad Sci Eng Technol 77:101–107

    Google Scholar 

  • Abdallah A, Yoshino H, Goto T, Enteria N, Radwan M, Abdelsamei Eid M (2013b) Integration of evaporative cooling technique with solar chimney to improve indoor thermal environment in the new city of Assiut, Egypt. Int J Energy Environ Eng 4:45

    Article  CAS  Google Scholar 

  • Alemu TA, Saman W, Belusko M (2012) A model for integrating passive and low energy airflow components into low rise buildings. Energy Build 49:148–157

    Article  Google Scholar 

  • ANSI/ASHRAE Standard 55 (2004) Thermal environmental conditions for human occupancy. American Society of Heating, Refrigerating and Air-conditioning Engineers, Inc., Atlanta, Georgia

    Google Scholar 

  • Arundel AV, Sterling EM, Biggin JH, Sterling TD (1986) Indirect health effects of relative humidity indoor environments. Environ Health Perspect 65:351–361

    CAS  Google Scholar 

  • Atthajariyakul S, Leephakpreeda T (2004) Real-time determination of optimal indoor-air condition for thermal comfort, air quality and efficient energy usage. Energy Build 36(7):720–733

    Article  Google Scholar 

  • Bahadori MN, Dehghani-Sanij AR (2014) Wind towers: architecture, climate and sustainability. Springer, Berlin

    Book  Google Scholar 

  • Bahadori MN, Mazidi M, Dehghani AR (2008) Experimental investigation of new designs of wind towers. Renew Energy 33:2273–2281

    Article  Google Scholar 

  • Bouchahm Y, Fatiha B, Azeddine B (2011) Performance analysis and improvement of the use of wind tower in hot dry climate. Rene Ener 36:898–906

    Article  Google Scholar 

  • Calautit J, Hughes BR, Nasir D (2016) Climatic analysis of a passive cooling technology for the built environment in hot countries. Appl Energy. https://doi.org/10.1016/j.apenergy.2016.05.096

    Article  Google Scholar 

  • Calautit JK, Aquino AI, Shahzad S, Nasir D, Hughes B (2017) Thermal comfort and indoor air quality analysis of a low-energy cooling windcatcher. Energy Procedia 105:2865–2870

    Article  Google Scholar 

  • Clements-Croome D (2000) Creating the productive workplace. Taylor and Francis, London

    Google Scholar 

  • Dehghani-sanij AR, Soltani M, Raahemifar K (2015) A new design of wind tower for passive ventilation in buildings to reduce energy consumption in windy regions. Renew Sustain Energy Reviw 42:182–195

    Article  Google Scholar 

  • Fanger PO (1972) Thermal comfort: analysis and applications in environmental engineering. Danish Technical Press, Copenhagen

    Google Scholar 

  • Farraj F, Loveday DL (2010) Indoor thermal conditions and thermal comfort in air-conditioned domestic buildings in the dry-desert climate of Kuwait. Build Environ 45:704–710

    Article  Google Scholar 

  • Haghighi AP, Pakdel SH, Jafari A (2016) A study of a wind catcher assisted adsorption cooling channel for natural cooling of a 2-storey building. Energy 102:118–138

    Article  Google Scholar 

  • Hosseini SH, Shokry E, Ahmadian Hosseini AJ, Ahmadi G, Calautit JK (2016) Evaluation of airflow and thermal comfort in buildings ventilated with wind catchers: simulation of conditions in Yazd City, Iran. Energy Sustain Dev 35:7–24

    Article  Google Scholar 

  • ISO 7730 (2005) Moderate thermal environments. Determination of the PMV and PPD indices and specification of the conditions for thermal comfort, 2nd edn. International Organisation for Standardisation, Geneva

    Google Scholar 

  • Khani MR, Bahadori MN, Dehghani-Sanij AR, Nourbakhsh A (2017a) Performance evaluation of a modular design of wind tower with wetted surfaces. Energy 10(845):1–22

    Google Scholar 

  • Khani MR, Bahadori MN, Dehghani-Sanij AR (2017b) Experimental investigation of a modular wind tower in hot and dry regions. Energy Sustain 39:21–28

    Article  Google Scholar 

  • Kosonen R, Tan F (2004) Assessment of productivity loss in air-conditioned buildings using PMV index. Energy Build 36(10):987–993

    Article  Google Scholar 

  • Nejat P, Calcutit JK, Abo Majid MZ, Hughes BR, Jomehzadeh F (2016) Anti-short-circuit device: a new solution for short-circuiting in windcatcher and improvement of natural ventilation performance. Build Environ 105:24–39

    Article  Google Scholar 

  • O’Connor D, Calautit JK, Hughes BR (2016) A novel design of a desiccant rotary wheel for passive ventilation applications. Appl Energy 179:99–109

    Article  Google Scholar 

  • Tyler H, Stefano S, Alberto P, Dustin M, Kyle S (2013) CBE thermal comfort tool, center for the built environment, University of California Berkeley. http://cbe.berkeley.edu/comforttool. Accessed Jan 2016

  • Yaghoubi MA, Sabzevari A, Golneshan A (1991) Wind towers-Measurement and performance. Solar Energy 47(2):97–106

    Article  Google Scholar 

Download references

Acknowledgments

This study is a part of a research project funded by STDF (The Ministry of State for Scientific Research, Egypt), Project No. 10255.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. S. H. Abdallah.

Additional information

Editorial responsibility: Mohamed Fathy Yassin.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Abdallah, A.S.H. A new design of passive air condition integrated with solar chimney for hot arid region of Egypt. Int. J. Environ. Sci. Technol. 16, 2611–2618 (2019). https://doi.org/10.1007/s13762-018-1804-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13762-018-1804-x

Keywords

Navigation