Skip to main content
Log in

Early corrosion monitoring of reinforcing steel bars by using long-gauge carbon fiber sensors

  • Original Paper
  • Published:
Journal of Civil Structural Health Monitoring Aims and scope Submit manuscript

Abstract

Corrosion of main steel reinforcements is one of the foremost causes of early deterioration and shortening of service life of reinforced concrete structures. Early detection of corrosion can aid in reducing the maintenance cost and extending the service life of structures. This research proposes an approach for early corrosion monitoring of steel reinforcements in concrete structures using strain measurements of long-gauge packaged carbon fiber line (PCFL) sensors. An accelerated corrosion method utilizing a salt solution and constant current was used to achieve the required corrosion levels. The effects of the salt solution, electrical current, and change in temperature during the corrosion process on the signals of the proposed packaged sensors were studied. A PCFL with temperature compensation and a protective cover was installed on a steel bar and tested under accelerated corrosion and a constant tensile load. Monitored measurements of the PCFL sensors during the corrosion progress were compared with a laboratory-scale model and measurements of packaged fiber Bragg grating (PFBG) sensors. The results confirmed that the proposed packaging could effectively protect the carbon fiber sensors from electric effects, long-term salt attack, and temperature variation during the corrosion process. The experimental results of both the PCFL and the PFBG sensors were in good agreement with the corrosion values calculated theoretically from Faraday’s law with a relative weight loss ratio error of less than 0.8. Therefore, the use of long-gauge PCFL sensors can be considered as a promising approach for monitoring the corrosion progress of steel reinforcements of large-scale structures.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15
Fig. 16

Similar content being viewed by others

References

  1. Khatri RP, Sirivivatnanon V (2004) Characteristic service life for concrete exposed to marine environments. Cem Concr Res 34(5):745–752

    Article  Google Scholar 

  2. Schueremans L, Van Gemert D, Giessler S (2007) Chloride penetration in RC-structures in marine environment–long term assessment of a preventive hydrophobic treatment. Constr Build Mater 21(6):1238–1249

    Article  Google Scholar 

  3. Zhang R, Castel A, François R (2010) Concrete cover cracking with reinforcement corrosion of RC beam during chloride-induced corrosion process. Cem Concr Res 40(3):415–425

    Article  Google Scholar 

  4. Oh BH, Kim KH, Jang BS (2009) Critical corrosion amount to cause cracking of reinforced concrete structures. ACI Mater J 106(4):333–339

    Google Scholar 

  5. Zhao Y, Yu J, Hu B, Jin W (2012) Crack shape and rust distribution in corrosion-induced cracking concrete. Corros Sci 55:385–393

    Article  Google Scholar 

  6. Gao J, Wu J, Li J, Zhao X (2011) Monitoring of corrosion in reinforced concrete structure using Bragg grating sensing. NDT E Int 44(2):202–205

    Article  Google Scholar 

  7. Zarrok H, Oudda H, Zarrouk A, Salghi R, Hammouti B, Bouachrine M (2011) Weight loss measurement and theoretical study of new pyridazine compound as corrosion inhibitor for C38 steel in hydrochloric acid solution. Der Pharma Chemica 3(6):576–590

    Google Scholar 

  8. Djeddi L, Khelif R, Benmedakhene S, Favergeon J (2013) Reliability of acoustic emission as a technique to detect corrosion and stress corrosion cracking on prestressing steel strands. Int J Electrochem Sci 8:8356–8370

    Google Scholar 

  9. Song HW, Saraswathy V (2007) Corrosion monitoring of reinforced concrete structures-A. Int J Electrochem Sci 2:1–28

    Google Scholar 

  10. Kuang F, Zhang J, Zou C, Shi T, Wang Y, Zhang S, Xu H (2010) Electrochemical methods for corrosion monitoring: a survey of recent patents. Recent Patents Corros Sci 2:34–39

    Article  Google Scholar 

  11. Tan CH, Shee YG, Yap BK, Adikan FM (2016) Fiber Bragg grating based sensing system: early corrosion detection for structural health monitoring. Sens Actuators A 246:123–128

    Article  Google Scholar 

  12. Leung CK, Wan KT, Chen L (2008) A novel optical fiber sensor for steel corrosion in concrete structures. Sensors 8(3):1960–1976

    Article  Google Scholar 

  13. Fuhr PL, Huston DR (1998) Corrosion detection in reinforced concrete roadways and bridges via embedded fiber optic sensors. Smart Mater Struct 7(2):217

    Article  Google Scholar 

  14. Wei H, Zhang P, Cui Y, Zhao X, Sun C (2014) Monitoring and evaluation of corrosion-induced expansion in the reinforced concrete structures. Yingyong Jichu yu Gongcheng Kexue Xuebao J Basic Sci Eng 22(3):556–565

    Google Scholar 

  15. Gotou T, Noda M, Tomiyama T, Sembokuya H, Kubouchi M, Tsuda K (2006) In situ health monitoring of corrosion resistant polymers exposed to alkaline solutions using pH indicators. Sens Actuators B 119(1):27–32

    Article  Google Scholar 

  16. Ansari F (1997) State-of-the-art in the applications of fiber-optic sensors to cementitious composites. Cem Concr Comp 19(1):3–19

    Article  Google Scholar 

  17. Yang CQ, Wu ZS (2007) In situ corrosion monitoring of PC structures with distributed hybrid carbon fiber reinforced polymer sensors. Smart Mater Struct 16(4):1050

    Article  Google Scholar 

  18. Li S, Wu Z (2007) Development of distributed long-gage fiber optic sensing system for structural health monitoring. Struct Health Monit 6(2):133–143

    Article  Google Scholar 

  19. Li S, Wu Z (2007) Modal analysis on macro-strain measurements from distributed long-gage fiber optic sensors. J Intell Mater Syst Struct 19(8):937–946

    Article  Google Scholar 

  20. Huang H, Wu ZS (2010) Small signal recognition system of CFRP strips during low strain rate tensile testing. J Appl Mech 13:963–970

    Google Scholar 

  21. Huang H, Wu ZS (2012) Static and dynamic measurement of low-level strains with carbon fibers. Sens Actuators A 183:140–147

    Article  Google Scholar 

  22. Huang H, Yang C, Wu ZS (2012) Electrical sensing properties of carbon fiber reinforced plastic strips for detecting low-level strains. Smart Mater Struct 21(3):035013

    Article  Google Scholar 

  23. Saifeldeen MA, Fouad N, Huang H, Wu ZS (2015) Health monitoring of bridges based on distributed long gauge carbon fiber sensors. 2nd international conference on bridge testing, monitoring & assessment, Cairo, Egypt

  24. Li S, Wu ZS (2005) Structural identification using static macro-strain measurements from long-gage fiber optic sensors. J Appl Mech 8:943–949

    Article  Google Scholar 

  25. Wan C, Hong W, Liu J, Wu Z, Xu Z, Li S (2013) Bridge assessment and health monitoring with distributed long-gauge FBG sensors. Int J Distrib Sens Netw 9(12):494260. doi:10.1155/2013/494260

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Z. S. Wu.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Fouad, N., Saifeldeen, M.A., Huang, H. et al. Early corrosion monitoring of reinforcing steel bars by using long-gauge carbon fiber sensors. J Civil Struct Health Monit 6, 691–701 (2016). https://doi.org/10.1007/s13349-016-0190-7

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13349-016-0190-7

Keywords

Navigation