Skip to main content
Log in

Experimental Study on Fire Resistance Performance of Concrete-Filled Steel Plate Composite Walls

  • Published:
International Journal of Steel Structures Aims and scope Submit manuscript

Abstract

Concrete-filled steel plate composite walls are increasingly used in high-rise buildings; their mechanical properties at room temperature have produced fruitful results. However, research on their mechanical properties in fire and at high temperatures is scarce. Moreover, published studies on the fire resistance of concrete-filled steel plate composite walls have not considered the impact of fire protection measures. Based on previous fire resistance research, a fire resistance test was designed in this study for four walls under the combined action of axial compression and a single-sided fire under the ISO-834 standard heating curve. Apart from that, the existing fire protections have the disadvantages of too thick, easy falling off and cracking or difficult to install. In order to eliminate the disadvantages of existing fire prevention measures, new composite fireproof structure using a rock wool board and a thin fire-retardant coating is proposed. The effects of no fireproof structures, autoclaved lightweight concrete plate fireproof structures, thick-coated fire-retardant structures, and new composite fireproof structures on the fire resistance of concrete-filled steel plate composite walls were studied experimentally. The results show that the fire resistance of the four test specimens meets the 3 h fire resistance limit of the primary load-bearing component in the specification. Based on the experimental results, reasonable fire protection methods are suggested for concrete-filled steel plate composite walls in actual projects, and an experimental basis is provided for further numerical simulation.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14

Similar content being viewed by others

References

  • Chen, Z.H., Du, Y.S., Wu, L. et al, Summary of research on rectangular concrete-filled steel tube structure, Building Structure, 45 (16) (2015) 40–46+76. DOI:https://doi.org/10.19701/j.jzjg.2015.16.009.

  • Chen, Z. H., Zhao, B. Z., Yu, J. H., et al. (2017). Residential design of rectangular steel tube concrete composite special-shaped column frame-shear wall structure system. Building Structure, 47(06), 1–6. https://doi.org/10.19701/j.jzjg.2017.06.001

    Article  Google Scholar 

  • EN 1994–1–2: 2005, Eurocode 4: design of composite steel and concrete structures-part 1–2: General rules-structural fire design, Brussels, Belgium, 2005.

  • Eom, T. S., Park, H. G., Lee, C. H., et al. (2009). Behavior of double skin composite wall subjected to in-plane cyclic loading. Journal of Structure Engineering, 135(10), 1239–1249. https://doi.org/10.1061/(ASCE)ST.1943-541X.0000057

    Article  Google Scholar 

  • Fang, C., Izzuddin, B. A., Elghazouli, A. Y., & Nethercot, D. A. (2011). Robustness of steel-composite building structures subject to localised fire. Fire Safety Journal, 46(6), 348–363. https://doi.org/10.1016/j.firesaf.2011.06.001

    Article  Google Scholar 

  • Fang, C., Izzuddin, B. A., Elghazouli, A. Y., & Nethercot, D. A. (2013). Robustness of multi-storey car parks under localised fire—Towards practical design recommendations. Journal of Constructional Steel Research, 90, 193–208. https://doi.org/10.1016/j.jcsr.2013.08.004

    Article  Google Scholar 

  • GB 14907–2018, Fire resistive coating for steel structure, Standardization Administration of the People's Republic of China, Beijing, China, 2018.

  • GB/T 9978.1–2008, Fire-resistance tests Elements of building construction, Standards Press of China, Bejing, China, 2008.

  • GB 50016–2014, Code for fire protection design of buildings, China Planing Press, Beijing, China, 2018.

  • GB 51249–2017, Code for fire safety of steel structures in buildings, China association for engineering construction standardization, Beijing, China, 2017.

  • GB15762–2008, Autoclaved aerated concrete slabs, China association for engineering construction standardization, Beijing, China, 2008.

  • Hu, H. S., Nie, J. G., & Eatherton, M. R. (2014). Deformation capacity of concrete-filled steel plate composite shear walls. Journal of Constructional Steel Research, 103, 148–158. https://doi.org/10.1016/j.jcsr.2014.08.006

    Article  Google Scholar 

  • ISO-834–1. Fire resistance tests - elements of building construction-part 1: general requirements, International Standard ISO 834, Geneva, 1999.

  • JGJ/T17–2008, Technical specification for application of autoclaved aerated concrete, China Architecture and Building Press, Beijing, China, 2008.

  • JGJ/T 380–2015, Technical specification for steel plate shear walls, China Architecture and Building Press, Beijing, China, 2015

  • Link, R. A., & Elwi, A. E. (1995). Composite concrete steel plate walls-analysis and behavior. Journal of Structure Engineering, 121(2), 260–271. https://doi.org/10.1061/(ASCE)0733-9445

    Article  Google Scholar 

  • Liu, G. R. (2010). Experimental study on fire-resistance and post-fire seisnic behavior of concrete shear walls. School of Civil Engineering of Dalian University of Techonlogy.

    Google Scholar 

  • Rafiei, S., Hossain, K. M. A., Lachemi, M., et al. (2013). Finite element modeling of double skin profiled composite shear wall system under in-plane loadings. Engineering Structures, 56, 46–57. https://doi.org/10.1016/j.engstruct.2013.04.014

    Article  Google Scholar 

  • Rafiei, S., Hossain, K. M. A., Lachemi, M., et al. (2015). Profiled sandwich composite wall with high performance concrete subjected to monotonic shear. Journal of Constructional Steel Research, 107, 124–136. https://doi.org/10.1016/j.jcsr.2015.01.015

    Article  Google Scholar 

  • Sener, K. C., Varma, A. H., & Ayhan, D. (2015). Steel-plate composite (SC) walls: Out-of-plate flexural behavior, database, and design. Journal of Constructional Steel Research, 108, 46–59. https://doi.org/10.1016/j.jcsr.2015.02.002

    Article  Google Scholar 

  • Song, T. Y., & Han, L. H. (2008). Some new developments of the fire performance research on composite structures. Engineering Mechanics, 25(S2), 230–253.

    Google Scholar 

  • Sun, K., Wei, F. F., Wang, Y. L., et al. (2014). Comparative analysis of fire resistance performance of steel plate shear wall and steel frame. Low Temperature Architecture Technology, 36(08), 31–33. https://doi.org/10.13905/j.cnki.dwjz.2014.08.029

    Article  Google Scholar 

  • Wei, F. F., Du, J. E., Hu, X. F., et al. (2016). Experimental research on fire performance of concrete filled double-steel-plate composite wall exposed to one-side fire. Journal of Southeast University (Natural Science Edition), 46(03), 518–522.

    Google Scholar 

  • Wei, F., Fang, C., & Wu, B. (2017). Fire resistance of concrete-filled steel plate composite(CFSPC) walls. Fire Safety Journal, 88, 26–39. https://doi.org/10.1016/j.firesaf.2016.12.008

    Article  Google Scholar 

  • Wei, F. F., Zheng, Z. J., Yun, J., et al. (2019). Structure behavior of concrete filled double-steel-plate composite walls under fire. Advances in Structural Engineering, 22(8), 1895–1908. https://doi.org/10.1177/1369433218825238

    Article  Google Scholar 

  • Wu, H., Wei, F.F., Qu, L.H. et al, (2014) Comparison and analysis of fire resistance performance of steel plate shear walls with different fire protection coatings, Sichuan Building Science, 40 (01), 76–78+108

  • Yan, J. B., Liu, X. M., Liew, J. Y. R., et al. (2016). Steel-concrete-steel sandwich system in Arctic offshore structure: Materials, experiments, and design. Materials and Design., 91, 111–121. https://doi.org/10.1016/j.matdes.2015.11.084

    Article  Google Scholar 

  • Zhang, K., Varma, A. H., Malushte, S. R., et al. (2014). Effect of shear connectors on local buckling and composite action in steel concrete composite walls. Nuclear Engineering and Design, 269, 231–239. https://doi.org/10.1016/j.nucengdes.2013.08.035

    Article  Google Scholar 

  • Zhao, B. Z., Chen, Z. H., Zheng, P. Z., et al. (2017). Fire resistance experiment on SCFRT column insulated with ALC Board. Journal of Tianjin University (Science and Technology), 50(09), 931–938.

    Google Scholar 

  • Zhao, Q. H., & Astaneh-Asl, A. (2004). Cyclic behavior of traditional and innovative composite shear walls. Journal of Structure Engineering, 130(2), 271–284. https://doi.org/10.1061/(ASCE)0733-9445

    Article  Google Scholar 

Download references

Acknowledgements

The research described in this paper was financially supported by the Natural Science Foundation of Hebei Province (Grant No. E2021402006)

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hongbo Liu.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law.

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Zhou, T., Liu, X., Liu, H. et al. Experimental Study on Fire Resistance Performance of Concrete-Filled Steel Plate Composite Walls. Int J Steel Struct 23, 389–403 (2023). https://doi.org/10.1007/s13296-022-00700-4

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13296-022-00700-4

Keywords

Navigation