Abstract
Based on fire tests, a parametric numerical simulation on the catenary action of restrained steel beams in fire was performed by the finite element software ABAQUS. It can be known that axial constraint stiffness, rotational constraint stiffness and load ratio are key factors that affect the catenary action in fire. The formation mechanism of catenary action under ISO-834 standard fire was studied; and the judgement method for catenary action in fire was presented. The results show that: (1) when axial constraint stiffness reaches a certain value, the catenary action of restrained steel beams will occur almost at the same time; (2) with the increase of rotational constraint stiffness or load ratio, the catenary action of steel beams will occur earlier; (3) for restrained steel beams under a small load ratio, the catenary action usually occurs in fire when the mid-span deformation reaches 1/15 of the span; but for restrained steel beams under a large load ratio, the catenary action usually occurs when the mid-span deformation reaches 1/18 of the span; (4) for restrained steel beams with a large rotational constraint stiffness, the judgement method for catenary action in fire can still adopt the same method as above, which will be a little conservative.
Similar content being viewed by others
References
ABAQUS. (2003). ABAQUS/standard user’s manual volumes I–III and ABAQUS CAE manual, version 6.4. Pawtucket: Hibbitt, Karlsson & Sorensen, Inc.
EN1993-1-2. (2005). Eurocode 3: Design of steel structures-Part 1.2: General rules—Structural fire design. Brussels: European Committee for Standardization, CEN.
Gui, H. Y. (2016). Research on catenary action of the restrained steel beams in fire. Thesis (Master), School of Civil Engineering, Southeast University, Nanjing.
Guo, S. X. (2006). The behaviour of restrained steel beam during heating and cooling and the damage of beam-to-column connection. Thesis (Master), School of Civil Engineering, Tongji University, Shanghai.
Heidarpour, A., & Bradford, M. A. (2009). Generic nonlinear modelling of restrained steel beams at elevated temperatures. Engineering Structures,31(11), 2787–2796.
Li, G. Q., & Guo, S. X. (2006). Analysis of restrained steel girders with large deformation subjected to elevated temperature. Journal of Tongji University (Natural Science),34(7), 853–858.
Liu, T. C. H., Fahad, M. K., & Davies, J. M. (2002). Experimental investigation of behaviour of axially restrained steel beams in fire. Journal of Constructional Steel Research,58(9), 1211–1230.
Lou, G. B., Li, G. Q., Wang, C. H., Jiang, J., et al. (2018). Fire tests on full-scale steel portal frames against progressive collapse. Journal of Constructional Steel Research,145, 137–152.
Ma, N. (2015). Catenary action of the restrained castellated steel beams in a fire. Thesis (Master), School of Civil Engineering, Shandong University, Jinan.
Wang, Y. C. (2000). An analysis of the global structural behaviour of the Cardington steel-framed building during the two BRE fire tests. Engineering Structures,22(5), 401–412.
Wang, Y. C. (2002). The importance of considering whole structural behaviour in fire. International Symposium on Structures in Fire,10, 119–132.
Yin, Y. Z., & Wang, Y. C. (2004). A numerical study of large deformation behaviour of restrained steel beams at elevated temperatures. Journal of Constructional Steel Research,60(7), 1029–1047.
Yin, Y. Z., & Wang, Y. C. (2005a). Analysis of catenary action in steel beams using a simplified hand calculation method, part 1: Theory and validation for uniform temperature distribution. Journal of Constructional Steel Research,61(2), 183–211.
Yin, Y. Z., & Wang, Y. C. (2005b). Analysis of catenary action in steel beams using a simplified hand calculation method, part 2: Validation for non-uniform temperature distribution. Journal of Constructional Steel Research,61(2), 213–234.
Zhang, Z., Liu, C. B., & Wang, P. J. (2015). Catenary action analysis of the axially restrained corrugated web steel beams in a fire. Progress in Steel Building Structures,17(5), 58–64.
Zhang, Z., Liu, C. B., & Wang, P. J. (2016). Parameter analysis of the mechanics performance of axially restrained corrugated web beams at elevated temperatures in a fire. Steel Construction,31(1), 94–99.
Acknowledgements
The authors gratefully acknowledge the financial support of the National Natural Science Foundation of China (Nos. 51378105, 51878146 and 51808117) and National Key Research and Development Program of China (No. 2017YFC0703802). The research was sponsored by Jiangsu Provincial Qing Lan Project and Jiangsu provincial Six Talent Peaks Project (No. JZ-001). These financial supports are gratefully acknowledged.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Liu, M., Fan, S., Guo, Y. et al. Research on the Judgement Method for Catenary Action of Restrained Steel Beams in Fire. Int J Steel Struct 20, 692–704 (2020). https://doi.org/10.1007/s13296-020-00315-7
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13296-020-00315-7