An Analytical Study on Structural Performance Evaluation of Coupled Steel Plate Shear Wall Systems

  • Keunyeong Oh
  • Heonjun Ha
  • Byeonghyeon Jo
  • Kangmin Lee
Article
  • 9 Downloads

Abstract

The purpose of this study was to evaluate the structural performance of coupled steel plate shear walls (SPSWs) using finite element analysis (FEA). SPSW systems have good ductility and energy dissipation capacity and are known to have the advantage that the structure weight can be reduced by using thin steel plate. Although a coupled SPSW system is composed of two SPSW systems and a coupling beam that connects them, there have been almost no studies on the structural performance of coupled SPSW systems. Therefore, in this study, after the effectiveness of the FEA model was verified based on a previous experimental study, parametric analytical studies were conducted using variables such as bay width and coupling beam length. The parametric studies showed that the model with a medium bay width achieved better structural performance and ductility capacity than other models. Also, in comparison to models with different coupling beam lengths, although the model with a short coupling beam showed superior strength, variation of coupling beam length did not result in a significant difference.

Keywords

Steel plate shear wall Coupled shear wall Coupling beam Seismic performance evaluation Finite element analysis (FEA) 

Notes

Acknowledgements

This research was supported by Mid-career Researcher Program through National Research Foundation of Korea (NRF) funded by the Ministry of Science, ICT and Future Planning (Grant No.: 2015R1A2A2A01006765).

References

  1. Choi, I. R. (2005). Cyclic behavior of framed steel plate walls. M.S. Dissertation, Seoul National University, Korea. (in Korean).Google Scholar
  2. Lee, M. H., & Moon, T. S. (2002). Researches and application of steel plate shear walls. Journal of Korean Society of Steel Construction, KSSC, 14(4), 137–143. (in Korean).Google Scholar
  3. Park, W. S. (2005). Shear strength of steel coupling beam-wall connections in a hybrid coupled shear wall systems. Ph.D. Dissertation, Chungnam National University, Korea.Google Scholar
  4. Paulay, T., & Priestley, M. J. N. (1992). Seismic design of reinforced concrete and masonry buildings. New York: Wiley.CrossRefGoogle Scholar
  5. Roberts, T. M. (1995). Seismic resistance of steel plate shear wall. Engineering Structures, 17(5), 344–351.CrossRefGoogle Scholar
  6. Song, H. B., & Yi, W. H. (2005a). Behavior, reinforcing details and design of steel coupling beams joint in coupled shear wall systems. Journal of Architectural Institute of Korea, AIK, 21(12), 109–118. (in Korean).Google Scholar
  7. Song, H. B., & Yi, W. H. (2005b). Embedment length of steel coupling beam in coupled shear wall system. Journal of Architectural Institute of Korea, AIK, 21(11), 43–50. (in Korean).MathSciNetGoogle Scholar
  8. Thorburn L. J., Kulak G. L., & Montgomery C. J. (1983). Analysis of steel plate shear walls. Structural engineering report No. 107, Department of Civil Engineering, University of Alberta, Canada.Google Scholar

Copyright information

© Korean Society of Steel Construction 2018

Authors and Affiliations

  1. 1.Department of Architectural EngineeringChungnam National UniversityDaejeonKorea