Abstract
Economical design of the column-foundation connections is difficult to achieve due to the complex structural details of the anchor frame in the foundation concrete following the arrangement of 2 or 3 lines of connections using anchors that are needed to deal with the enlargement of the constructions. This study identified the problems of the conventional circular CFT column-foundation connections and proposed structural details to solve them. As a solution, high-tension bolts were adopted instead of the common anchors to provide new structural details enabling the anchor frame supporting the anchored connection to be omitted. Based on these new structural details, the specimens were manufactured with different types of internal reinforcements. The corresponding failure patterns, deformation capacities, and energy absorption hysteresis were compared and the behavior was analyzed to propose a rational shape of the connection details.
Similar content being viewed by others
References
Kim, E. H. (2003). Design of steel column base plates for concentric load. Master’s thesis, Hoseo University, Asan, Korea (in Korean).
KROAD (2010). Highway Bridge Design Code. Korean Road & Transportation Association, Gyeonggi, Korea (in Korean).
KSSC (2006). Steel Bridge Details Guidelines. Korean Society of Steel Construction, Seoul, Korea (in Korean).
KSSC (2010). Column-Base Plate Connection Design Guide. Korean Society of Steel Construction, Seoul, Korea (in Korean).
Lee, D. Y., Goel, S. C. and Stojadinovic, B. (2008a). “Exposed Column-Base Plate Connections Bending about Weak Axis: I. Numerical Parametric Study.” International Journal of Steel Structures, KSSC, 8(1), pp. 11–27.
Lee, D. Y., Goel, S. C. and Stojadinovic, B. (2008b). “Exposed column-base plate connections bending about weak axis: II. experimental study.” International Journal of Steel Structures, KSSC, 8(1), pp. 29–41.
LIST (1998). Design Manual of Steel Framed Pier. Research Institute of Industrial Science & Technology, Pohang, Korea (in Korean).
Marson, J. and Bruneau, M. (2004). “Cyclic testing of concrete-filled circular steel bridge piers having encased fixed-based detail.” Journal of Bridge Engineering, ASCE, 9, pp. 14–23.
Park, Y. M., Hwang W. S., Yoon, T. Y. and Hwang, M. O. (2005). “A new base plate system using deformed reinforcing bars for concrete filled tubular column.” Steel and Composite Structures, Techno-Press, 5(5), pp. 375–394.
Razzaghi, J. and Khoshbakht, A. (2015). “Numerical evaluation of column base rigidity.” International Journal of Steel Structures, KSSC, 15(1), pp. 39–49.
Shim, C. S., Chung, Y. S. and Yoon, J. Y. (2011). “Cyclic behavior of prefabricated circular composite columns with low steel ratio.” Engineering Structures, Elsevier B.V., 33, pp. 2525–2534.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Kim, HJ., Ham, J., Park, KT. et al. Experimental study of the behavior of circular column-foundation connections according to the internal reinforcement of the column. Int J Steel Struct 16, 877–885 (2016). https://doi.org/10.1007/s13296-016-0032-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13296-016-0032-9