Skip to main content
Log in

Comparison of bolted end plate and T-stub connections sensitivity to bolt diameter on cyclic behavior

  • Published:
International Journal of Steel Structures Aims and scope Submit manuscript

Abstract

Considering the construction limitations, proper and correct design of connections is vital and of great importance. At the construction stage, it is probable to use a connection bolt with a diameter less than the design assumptions. It can occur due to an imperfection in construction or even to changes in the function of the building. The unforeseen changes can increase the structural load, and consequently the moment and shear force demand values. Therefore, the present paper is aimed to examine the sensitivity of the bolted connections to the diameter of bolts using a numerical method. The results show that bolted T-stub connections are more sensitive to bolt diameter than end plate connections. Hence, the bolted end plate connections are recommended where the imperfection in construction or changes in function of the building is probable. Moreover, in construction of bolted connections, if changing the number of bolts regarding the constant total cross sectional area is considered, it is recommended to use the symmetric arrangement of bolts on each beam flange. In design of connections for a particular frame according to AISC, the moment capacity of T-stub connection is higher than that of end plate connection. However, the total energy absorptions of these connection types are approximately equal.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • Abidelah, A., Bouchaïr, A., Kerdal, D. E. (2012). “Experimental and analytical behavior of bolted end-plate connections with or without stiffeners.” J. Construct. Steel Res., 76, pp. 13–27.

    Article  Google Scholar 

  • Abolmaali. A., Kukreti, A. R., Motahari, A., and Ghassemieh, M. (2009). “Energy dissipation characteristics of semirigid connections.” J. Construct. Steel Res., 65, pp. 1187–1197.

    Article  Google Scholar 

  • AISC (1980). Manual of steel construction. 8th ed., American Institute of Steel Construction, Chicago.

    Google Scholar 

  • Amir, S. D., Mohammadreza, S., Hamid, S., Vahid, S., and Ahmad, B. M. (2012). “Behavior of semi-rigid connections and semi-rigid frames.” Journal of The Structural Design of Tall and Special Buildings, DOI: 10.1002/tal.1032.

    Google Scholar 

  • ANSYS (2006). ANSYS User’s manual. Version10.0. ANSYS Inc.

    Google Scholar 

  • Bahaari, M. R. and Sherbourne, A. N. (1994). “Computer modeling of an extended end-plate bolted connection.” Computers & Structures, 52(5), pp. 879–893.

    Article  MATH  Google Scholar 

  • Bursi, O. S. and Jaspart, J. P. (1997). “Calibration of finite element model for isolated bolted end-plate steel connection.” J. Construct. Steel Res., 44(3), pp. 225–262.

    Article  Google Scholar 

  • FEMA-350 (2000). Recommended seismic design criteria for new steel moment frame buildings. Report no. FEMA-350, Federal Emergency Management Agency, California Universities for Research in Earthquake Engineering

    Google Scholar 

  • Hu, Y., Davison, B,. Burgess, I., and Plank, R. (2009). “Component modelling of flexible end-plate connections in fire.” International Journal of Steel Structures, 9(1), pp. 1–15.

    Article  Google Scholar 

  • Lee, J., Goldsworthy, H. M., and Gad, E. F. (2011). “Blind bolted moment connection to unfilled hollow section columns using extended T-stub with back face support.” Eng. Struct., 33, pp. 1710–1722.

    Article  Google Scholar 

  • Mistakidis, E. S., Baniotopoulos, C. C., Bisbos, C. D., and Panagiotopoulos, P. D. (1997). “Steel T-stub connections under static loading: an effective 2-D numerical model.” J. Construct. Steel Res., 44(1–2), pp. 51–67.

    Article  Google Scholar 

  • Nemati, N., Houedec, D., L., and Zandonini, R. (2000), “Numerical modelling of the cyclic behaviour of the basic components of steel end plate connections.” Advances in Engineering Software, 31, pp. 837–849.

    Article  Google Scholar 

  • Popov, E. and Takhirov, S. (2002). “Bolted large seismic steel beam-to-column connections. Part 1: experimental study.” Eng. Struct., 24, pp. 1523–1534.

    Article  Google Scholar 

  • Sumner, E. A., Mays, T. W., and Murray, T. M. (2000). Cyclic testing of bolted moment end-plate connections. Research report SAC/BD-00/21. CE/VPI-ST 00/03, Department of Civil and Environmental Engineering, Virginia Polytechnic Institute and State University, Blacksburg, VA.

    Google Scholar 

  • Sumner, E. A. (2003). Unified design of extended end plate moment connections subject to cyclic loading. Ph.D. dissertation, Virginia Polytechnic Institute and State University, Blackburg, VA.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Hamid Saberi.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Saberi, H., Kheyroddin, A. & Gerami, M. Comparison of bolted end plate and T-stub connections sensitivity to bolt diameter on cyclic behavior. Int J Steel Struct 14, 633–647 (2014). https://doi.org/10.1007/s13296-014-3021-x

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13296-014-3021-x

Keywords

Navigation