Das IJ, Ding GX, Ahnesjo A (2008) Small fields: nonequilibrium radiation dosimetry. Med Phys 35:206–215
Article
PubMed
Google Scholar
Benedict SH, Yenice KM, Followill D et al (2010) Stereotactic body radiation therapy: the report of AAPM Task Group 101. Med Phys 37:4078–4101
Article
PubMed
Google Scholar
Morales JE, Crowe SB, Hill R, Freeman N, Trapp JV (2014) Dosimetry of cone-defined stereotactic radiosurgery fields with a commercial synthetic diamond detector. Med Phys 41:111702
Article
PubMed
Google Scholar
Li S, Rashid A, He S, Djajaputra D (2004) A new approach in dose measurement and error analysis for narrow photon beams: beamlets shaped by different multileaf collimators using a small detector. Med Phys 31:2020–2032
Article
PubMed
Google Scholar
Zhu XR, Allen JJ, Shi J, Simon WE (2000) Total scatter factors and tissue maximum ratios for small radiosurgery fields: comparison of diode detectors, a parallel-plate ion chamber, and radiographic film. Med Phys 27:472–477
CAS
Article
PubMed
Google Scholar
Ding GX, Duggan DM, Coffey CW (2006) Commissioning stereotactic radiosurgery beams using both experimental and theoretical methods. Phys Med Biol 51:2549–2566
Article
PubMed
Google Scholar
McKerracher C, Thwaites DI (1999) Assessment of new small-field detectors against standard-field detectors for practical stereotactic beam data acquisition. Phys Med Biol 44:2143–2160
CAS
Article
PubMed
Google Scholar
Dieterich S, Sherouse GW (2011) Experimental comparison of seven commercial dosimetry diodes for measurement of stereotactic radiosurgery cone factors. Med Phys 38:4166–4173
Article
PubMed
Google Scholar
Laub WU, Wong T (2003) The volume effect of detectors in the dosimetry of small fields used in IMRT. Med Phys 30:341–347
CAS
Article
PubMed
Google Scholar
Scott AJ, Kumar S, Nahum AE, Fenwick JD (2012) Characterizing the influence of detector density on dosimeter response in non-equilibrium small photon fields. Phys Med Biol 57:4461–4476
Article
PubMed
Google Scholar
Francescon P, Cora S, Cavedon C (2008) Total scatter factors of small beams: a multidetector and Monte Carlo study. Med Phys 35:504–513
Article
PubMed
PubMed Central
Google Scholar
Cranmer-Sargison G, Weston S, Evans JA, Sidhu NP, Thwaites DI (2012) Monte Carlo modelling of diode detectors for small field MV photon dosimetry: detector model simplification and the sensitivity of correction factors to source parameterization. Phys Med Biol 57:5141–5153
CAS
Article
PubMed
Google Scholar
Cranmer-Sargison G, Weston S, Evans JA, Sidhu NP, Thwaites DI (2011) Implementing a newly proposed Monte Carlo based small field dosimetry formalism for a comprehensive set of diode detectors. Med Phys 38:6592–6602
CAS
Article
PubMed
Google Scholar
Charles PH, Crowe SB, Kairn T et al (2013) Monte Carlo-based diode design for correction-less small field dosimetry. Phys Med Biol 58:4501–4512
CAS
Article
PubMed
Google Scholar
Charles PH, Cranmer-Sargison G, Thwaites DI et al (2014) Design and experimental testing of air slab caps which convert commercial electron diodes into dual purpose, correction-free diodes for small field dosimetry. Med Phys 41:101701
CAS
Article
PubMed
Google Scholar
Ralston A, Liu P, Warrener K, McKenzie D, Suchowerska N (2012) Small field diode correction factors derived using an air core fibre optic scintillation dosimeter and EBT2 film. Phys Med Biol 57:2587–2602
Article
PubMed
Google Scholar
Kairn T, Crowe SB, Kenny J, Trapp JV (2011) Investigation of stereotactic radiotherapy dose using dosimetry film and Monte Carlo simulations. Radiat Meas 46:1985–1988
CAS
Article
Google Scholar
Pappas E, Maris TG, Zacharopoulou F et al (2008) Small SRS photon field profile dosimetry performed using a PinPoint air ion chamber, a diamond detector, a novel silicon-diode array (DOSI), and polymer gel dosimetry. Analysis and intercomparison. Med Phys 35:4640–4848
CAS
Article
PubMed
Google Scholar
Kairn T, Taylor ML, Crowe SB et al (2012) Monte Carlo verification of gel dosimetry measurements for stereotactic radiotherapy. Phys Med Biol 57:3359–3369
CAS
Article
PubMed
Google Scholar
Belec J, Patrocinio H, Verhaegen F (2005) Development of a Monte Carlo model for the Brainlab microMLC. Phys Med Biol 50:787–799
Article
PubMed
Google Scholar
Kairn T, Kenny J, Crowe SB et al (2010) Technical note: Modelling a complex micro-multileaf collimator using the standard BEAMnrc distribution. Med Phys 37:1761–1767
CAS
Article
PubMed
Google Scholar
Kairn T, Charles PH, Crowe SB, Langton CM, Trapp JV (2015) Clinical use of diodes and micro-chambers to obtain accurate small field output factor measurements. Australas Phys Eng Sci Med 38:357–367
CAS
Article
PubMed
Google Scholar
Kawrakow I (2005) egspp: the EGSnrc C++ class library, NRCC Report PIRS-899, National Research Council of Canada
Alfonso R, Andreo P, Capote R, Huq MS, Kilby W, Kjall P, Mackie TR, Palmans H, Rosser K, Seuntjens J, Ullrich W, Vatnitsky S (2008) A new formalism for reference dosimetry of small and nonstandard fields. Med Phys 35(11):5179–5186
CAS
Article
PubMed
Google Scholar
Standard Imaging (2013) Exradin Detectors (product brochure), accessible from http://www.standardimaging.com/exradin/micro-ion-chambers/
Crowe SB, Kairn T, Middlebrook N et al (2013) Retrospective evaluation of dosimetric quality for prostate carcinomas treated with 3D conformal, intensity-modulated and volumetric-modulated arc radiotherapy. J Med Radiat Sci 60:131–138
Article
PubMed
PubMed Central
Google Scholar
Kairn T, Crowe SB, Kenny J, Knight RT, Trapp JV (2014) Predicting the likelihood of QA failure using treatment plan accuracy metrics. J Phys Conf Ser 489:012051
Article
Google Scholar
Crowe SB, Kairn T, Kenny J et al (2014) Treatment plan complexity metrics for predicting IMRT pre-treatment quality assurance results. Australas Phys Eng Sci Med 37:475–482
CAS
Article
PubMed
Google Scholar
Ezzell GA, Burmeister JW, Dogan N et al (2009) IMRT commissioning: multiple institution planning and dosimetry comparisons, a report from AAPM Task Group 119. Med Phys 36(11):5359–5373
Article
PubMed
Google Scholar
Kairn T, Charles P, Crowe SB, Trapp JV (2014) Effects of small field output factors on IMRT optimisation and dose calculation. Australas Phys Eng Sci Med 37(1):214–215
Google Scholar
Charles PH, Cranmer-Sargison G, Thwaites DI et al (2014) A practical and theoretical definition of very small field size for radiotherapy output factor measurements. Med Phys 41:041707
CAS
Article
PubMed
Google Scholar