Abstract

We fabricated a simple fluidic device consisting of a needle, a glass capillary, and a Tygon® tube to produce oil-in-water (O/W) emulsion droplets. In the fluidic device, the flow rate of the continuous phase was adjusted by a syringe or peristaltic pump, where a syringe pump was used for the discontinuous phase. We compared the performance of the syringe and peristaltic pump for the continuous phase in terms of the average diameter and coefficient of variance of the resultant O/W emulsion droplets. It was found that uniform droplets could be obtained when the production frequency was well matched. In addition, the flow behavior of the discontinuous phase during droplet formation was monitored using a high-speed camera, observing the back pressure in the peristaltic pump. By employment of a peristaltic pump for the continuous phase, it was possible to prepare a large amount of emulsion droplets.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. R. Langer and N. A. Peppas, J. Macromol. Sci., Rev. Macromol. Chem. Phys., C23, 61 (1983).

    Article  CAS  Google Scholar 

  2. R. Langer, Science, 249, 1527 (1990).

    Article  CAS  Google Scholar 

  3. K. E. Uhrich, S. M. Cannizzaro, R. S. Langer, and K. M. Shakesheff, Chem. Rev., 99, 3181 (1999).

    Article  CAS  Google Scholar 

  4. S. Margel and M. Offarim, Anal. Biochem., 128, 342 (1983).

    Article  CAS  Google Scholar 

  5. F. Pittner, T. Miron, G. Pittner, and M. Wilchek, J. Solid Phase Biochem., 5, 167 (1980).

    Google Scholar 

  6. Z. A. Tokes, K. E. Rogers, and A. Rembaum, Proc. Natl. Acad. Sci. U.S.A., 79, 2026 (1982).

    Article  CAS  Google Scholar 

  7. Q. Xu, M. Hashimoto, T. T. Dang, T. Hoare, D. S. Kohane, G. M. Whitesides, R. Langer, and D. G. Anderson, Small, 5, 1575 (2009).

    Article  CAS  Google Scholar 

  8. C.-H. Yang, Y.-S. Lin, K.-S. Huang, Y.-C. Huang, E.-C. Wang, J.-Y. Jhong, and C.-Y. Kuo, Lab Chip, 9, 145 (2009).

    Article  CAS  Google Scholar 

  9. T. Nisisako, S. Okushima, and T. Torii, Soft Matter, 1, 23 (2005).

    Article  CAS  Google Scholar 

  10. A. R. Abate and D. A. Weitz, Small, 5, 2030 (2009).

    Article  CAS  Google Scholar 

  11. M. Seo, C. Paquet, Z. H. Nie, S. Q. Xu, and E. Kumacheva, Soft Matter, 3, 986 (2007).

    Article  CAS  Google Scholar 

  12. S.-W. Choi, I. W. Cheong, J.-H. Kim, and Y. Xia, Small, 5, 454 (2009).

    Article  CAS  Google Scholar 

  13. S.-W. Choi, Y. Zhang, and Y. Xia, Adv. Funct. Mater., 19, 2943 (2009).

    Article  CAS  Google Scholar 

  14. S.-W. Choi, Y.-C. Yeh, Y. Zhang, H.-W. Sung, and Y. Xia, Small, 6, 1492 (2010).

    Article  CAS  Google Scholar 

  15. S.-K. Moon, M.-J. Oh, D.-H. Paik, T.-K. Ryu, K. Park, S.-E. Kim, J.-H. Kim, and S.-W. Choi, Macromol. Rapid Commun., 34, 399 (2013).

    Article  CAS  Google Scholar 

  16. J. Eggers, Rev. Mod. Phys., 69, 865 (1997).

    Article  CAS  Google Scholar 

  17. D. T. Papageorgiou, Phys. Fluids, 7, 1529 (1995).

    Article  CAS  Google Scholar 

  18. L. Rayleigh, Proc. R. Soc. London, 29, 71 (1879).

    Article  Google Scholar 

  19. S. Okushima, T. Nisisako, T. Torii, and T. Higuchi, Langmuir, 20, 9905 (2004).

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sung-Wook Choi.

Additional information

These authors contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Hwang, SJ., Moon, SK., Kim, S.E. et al. Production of uniform emulsion droplets using a simple fluidic device with a peristaltic pump. Macromol. Res. 22, 557–561 (2014). https://doi.org/10.1007/s13233-014-2074-1

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s13233-014-2074-1

Keywords

Navigation