Abstract
To evaluate the pattern of stress dissipation underneath the complete denture with various angled posterior teeth in both maxillary and mandibular arch. A 3D finite element models of residual ridge, mucosa, denture base in the coronal section were created from the dentures obtained from a patient, which were scanned and modeled. The coronal portion of the teeth was altered to stimulate the cuspal inclination of 0°, 20° and 33°, thus making the models. Special area of interest in bone, denture were selected to record the stresses. An vertical static load of 100N was applied through the mandibular model to the maxillary model. von Mises stresses developed in all the models were interpreted. Statistical analysis for comparison of stress values with different variables (0°–20°, 0°–33°, and 20°–33°) in various predefined areas of coronal section model was done using Student’s t test (paired). Stress of greater magnitude were observed with cuspal teeth i.e. 33° and 20°, where as 0° showed slightly less magnitude of stresses.
Similar content being viewed by others
References
Darbar UR, Huggett R, Harrison A (1994) Stress analysis technique in complete dentures. J Dent 22:259–264
Lawson WA (1960) The validity of a method used for measuring masticatory forces. J Prosthet Dent 10:99–111
Kelsy CC, Reid FD, Coplowitz JA (1976) A method of measuring pressures against tissues supporting functioning complete dentures. J Prosthet Dent 35:376–383
Clough HE, Knodle JM, Leeper SH, Pudwill ML, Taylor TD (1983) A comparison of lingualized occlusion and monoplane occlusion in complete denture. J Prosthet Dent 50:176–179
Inove S, Kawano F, Nagao K, Matsumoto N (1996) An in vitro study of the influence of occlusal scheme on the pressure distribution of complete denture supporting tissues. Int J Prosthodont 9:179–187
Frechette AR (1955) Comparison of balanced and non-balanced occlusion of artificial dentures based upon distribution of masticatory force. J Prosthet Dent 5(6):801–809
Takayama Y, Yamada T, Araki O, Seki T, Kawasaki T (2001) The dynamic behavior of a lower complete denture during unilateral loads: analysis using the finite element method. J Oral Rehabil 28:1064–1074
Mories JC, Khan Z, von Fraunhofer JA (1985) Palatal shape and the flexural strength of maxillary denture bases. J Prosthet Dent 53:670
Prombanas AE, Vlissids DS (2006) Comparison of the midline stress fields in maxillary and mandibular complete denture: a pilot study. J Prosthet Dent 95:63–70
El Ghazali S, Glantz PO, Strandman E, Randow K (1989) On the clinical deformation of maxillary complete dentures. Influence of denture base design and shape of denture-bearing tissue. Acta Odontol Scand 47:69–76
Dirtoft BI, Jansson JF, Abramson NH (1985) Using holography for the measurement of in vivo deformation in a complete maxillary denture. J Prosthet Dent 54:843–846
Prombanas AE, Vlissids DS (2002) Effects of the position of artificial teeth and load levels on the stress in the complete maxillary denture. J Prosthet Dent 88:414–422
Swoope CC, Kydd WL (1966) The effect of cusp form and occlusal surface area on denture base deformation. J Prosthet Dent 16:34–39
De Forest AV, Ellis G, Stern FB (1942) Brittle coating for quantitative strain measurements. J Appl Mech Trans ASME 64A:184–188
Mathews EM, Wain EA (1956) Stresses in denture bases. Br Dent J 100:167–171
Regli CP, Gaskill HL (1954) Denture base deformation during function. J Prosthet Dent 4:548–554
Rapp R (1954) The occlusion and occlusal patterns of artificial posterior teeth. J Prosthet Dent 4:548–554
Turner MJ, Clough RW, Martin HC, Top LJ (1956) Stiffness and deflection analysis of complex structures. J Aerosp Sci 23:805
Nishigawa G, Matsunaga T, Maruo Y, Okamoto M, Natsuaki N, Minagi S (2003) Finite element analysis of the effect of the denture supporting bone of the edentulous patient. J Oral Rehabil 30:646–652
Ates M, Cilinger A, Sulun T, Sunbuloglu E and Bozdag E (2006) The effect of occlusal contact localization on the stress distribution in complete maxillary denture. J Oral Rehabil 33:509–513
Atwood DA (1971) Clinical, cephalometric and densitometric study of the reduction of residual ridges. J Prosthet Dent 26:280
Kawano F, Koran III A, Asaoka K, Matsumoto N (1993) Effect of soft denture linear on stress distribution in supporting structures under a denture. Int J Prosthodont 6:43–49
Darbar UR, Huggett R, Harrison A (1995) Finite element analysis of stress distribution at the tooth denture base interface of acrylic resin teeth debonding from the denture base. J Prosthet Dent 74:591–594
Lambrecht JR, Kydd WL (1962) A functional stress analysis of the maxillary complete denture base. J Prosthet Dent 12(5):865
Lopuck S, Smith J, Caputo A (1978) Photoelastic comparison of posterior denture occlusion. J Prosthet Dent 40(1):18–21
Maeda Y, Wood WW (1989) Finite element method simulation of bone resorption beneath a complete denture. J Dent Res 68:1370–1373
Kydd WK ,Daly CH (1982) The biologic and mechanical effects of stress on oral mucosa. J Prosthet Dent 47:317–329
EMRC manual
Sharry JJ, Askaw HC, Hoyer H (1960) Influence of artificial tooth forms on bone deformation beneath complete dentures. J Dent Res 39:253–266
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Mankani, N., Chowdhary, R. & Mahoorkar, S. Comparison of Stress Dissipation Pattern Underneath Complete Denture with Various Posterior Teeth form: An In Vitro Study. J Indian Prosthodont Soc 13, 212–219 (2013). https://doi.org/10.1007/s13191-012-0193-y
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13191-012-0193-y