Abstract
The unstable state of nitrite results in its very low concentration in seawater, which is below the limit of detection (LOD) of conventional techniques of analysis. Some sensitivity-enhanced methods have been proposed for the determination of nitrite at nanomolar level to illustrate the role of nitrite in the marine nitrogen cycle. However, most of previous reports are not widely accepted, because of their complexity and cost equipment or intensive labor requirement. In this study, a simple automatic system for the determination of nanomolar level nitrite using on-line preconcentration with spectrophotometric detection was described. An Oasis HLB cartridge was adopted to quantitatively enrich the pink-colored azo compound, formed from nitrite via Griess reaction. The cartridge was rinsed with water and ethanol (volume fraction is 55%, the same below), in turn, then eluted by an eluent containing 50% ethanol and 0.25 M(mol/dm3) H2SO4, and determined at 543 nm with a 2 cm path-length flow cell. Under the optimized experimental conditions, the calibration curve showed a good linearity in the range of 1.4–85.7 nM, and the LOD (3σ) was estimated to be 0.5 nM. The relative standard deviations of 7 measurements were 4.0% and 1.0% for the samples spiked at 7.1 and 28.6 nM, respectively. The recoveries for the different natural water samples were between 92.2%–108.4%. Each HLB cartridge could be reused for at least 50 times. As compared with other SPE methods, the advantages of this method included the free of interference from salinity variation and less sample consuming. The results of the application of the proposed method to natural water showed good agreement with liquid waveguide capillary cell detection method.
Similar content being viewed by others
Explore related subjects
Discover the latest articles and news from researchers in related subjects, suggested using machine learning.References
Adornato L R, Kaltenbacher E A, Greenhow D R, et al. 2007. High-resolution in situ analysis of nitrate and phosphate in the oligotrophic ocean. Environ Sci Technol, 41: 4045–4052
Axelrod H D, Engel N A. 1975. Fluorometric determination of subnanogram levels of nitrite using 5-aminofluorescein. Anal Chem, 47: 922–924
Braman R S, Hendrix S A. 1989. Nanogram nitrite and nitrate determination in environmental and biological materials by vanadium (iii) reduction with chemiluminescence detection. Anal Chem, 61: 2715–2718
Brandes J A, Devol A H, Deutsch C. 2007. New developments in the marine nitrogen cycle. Chem Rev, 107: 577–589
Chen G, Yuan D, Huang Y, et al. 2008. In-field determination of nanomolar nitrite in seawater using a sequential injection technique combined with solid phase enrichment and colorimetric detection. Anal Chim Acta, 620: 82–88
Cox R D. 1980. Determination of nitrate and nitrite at the parts per billion level by chemiluminescence. Anal Chem, 52: 332–335
Dore J E, Karl D M. 1996a. Nitrification in the euphotic zone as a source for nitrite, nitrate, and nitrous oxide at station ALOHA. Limnol Oceanogr, 1619–1628
Dore J E, Karl D M. 1996b. Nitrite distributions and dynamics at station ALOHA. Deep-Sea Res II, 43: 385–402
French D, Furnas M J, Smayda T J. 1983. Diel changes in nitrite concentration in the chlorophyll maximum in the gulf of mexico. Deep-Sea Res, 30: 707–722
Garside C. 1982. A chemiluminescent technique for the determination of nanomolar concentrations of nitrate and nitrite in seawater. Mar Chem, 11: 159–167
Gimbert L J, Worsfold P J. 2007. Environmental applications of liquid-waveguide-capillary cells coupled with spectroscopic detection. Trend Anal Chem, 26: 914–930
Grashoff K, Ehrhardt M, Kremling K. 1983. Methods of seawater analysis. Verlag Chemie: Weinheim, pp: 139–142
Kieber R J, Seaton P J. 1995. Determination of subnanomolar concentrations of nitrite in natural waters. Anal Chem, 67: 3261–3264
Liang Y, Yuan D, Li Q, et al. 2007. Flow injection analysis of nanomolar level orthophosphate in seawater with solid phase enrichment and colorimetric detection. Mar Chem, 103: 122–130
Ma J, Yuan D, Liang Y. 2008. Sequential injection analysis of nanomolar soluble reactive phosphorus in seawater with HLB solid phase extraction. Mar Chem, 111: 151–159
Masserini R T, Fanning K A. 2000. A sensor package for the simultaneous determination of nanomolar concentrations of nitrite, nitrate, and ammonia in seawater by fluorescence detection. Mar Chem, 68: 323–333
Miró M, Cladera A, Estela J M, et al. 2000. Sequential injection spectrophotometric analysis of nitrite in natural waters using an on-line solid-phase extraction and preconcentration method. Analyst, 125: 943–948
Motomizu S, Mikasa H, Toei K. 1986. Fluorometric determination of nitrite in natural waters with 3-aminonaphthalene-1, 5-disulphonic acid by flow-injection analysis. Talanta, 33: 729–732
Pai S C, Chung S W, Ho T Y, et al. 1996. Determination of nano-molar levels of nitrite in natural water by spectrophotometry after pre-concentration using Sep-pak C18 cartridge. Int J Environ Anal Chem, 62: 175–189
Patey M D, Rijkenberg M J A, Statham P J, et al. 2008. Determination of nitrate and phosphate in seawater at nanomolar concentrations. Trend Anal Chem, 27: 169–182
Ren J, Mi T, Dou W, et al. 2008. Colorimetric determination of nanomolar concentrations of silicate in natural waters after liquid-liquid extraction using methyl isobutyl ketone. Acta Oceanol Sin, 27: 137–146
Ryther J H, Dunstan W M. 1971. Nitrogen, phosphorus, and eutrophication in the coastal marine environment. Science, 171: 1008–1013
Yao W S, Byrne R H, Waterbury R D. 1998. Determination of nanomolar concentrations of nitrite and nitrate in natural waters using long path length absorbance spectroscopy. Environ Sci Technol, 32: 2646–2649
Zafiriou O C, Ball L A, Hanley Q. 1992. Trace nitrite in oxic waters. Deep-sea Res I, 39: 1329–1347
Zhang J Z. 2000. Shipboard automated determination of trace concentrations of nitrite and nitrate in oligotrophic water by gas-segmented continuous flow analysis with a liquid waveguide capillary flow cell. Deep-Sea Res I, 47: 1157–1171
Zhang J Z. 2006. Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection. Anal Sci, 22: 57–60
Author information
Authors and Affiliations
Corresponding author
Additional information
Foundation item: The National High Technology Research and Development Program of China under contract Nos 2006AA09Z174 and 2007AA061501; the National Natural Science Foundation of China under contract No. 40521003.
Rights and permissions
About this article
Cite this article
Zhang, M., Yuan, D., Huang, Y. et al. Sequential injection spectrophotometric determination of nanomolar nitrite in seawater by on-line preconcentration with HLB cartridge. Acta Oceanol. Sin. 29, 100–107 (2010). https://doi.org/10.1007/s13131-010-0012-4
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s13131-010-0012-4


