Evaluation for the efficacy and safety of the crosser catheter as a CTO crossing device and a flossing device

  • Original Article
  • Published:
Cardiovascular Intervention and Therapeutics Aims and scope Submit manuscript

Abstract

The Crosser catheter is a unique device that facilitates antegrade intraluminal recanalization by high-frequency vibration energy and cavitation. We used this device not only as a chronic total occlusion (CTO) crossing device, but also as a flossing device in stenotic lesions and we also evaluated the efficacy of this device when used with both the “Crosser preceding” and the “Guidewire preceding” in CTOs. Complications related to this device were investigated, too. We retrospectively analyzed a total of 90 consecutive patients with peripheral artery disease in the femoropopliteal artery and below-the-knee artery (BTA). Primary technical success was defined as the successful delivery of this device into the distal true lumen. Secondary technical success was defined as successful revascularization. The safety endpoints were events of angiographic complications, including the occurrence of detachment of the metal tip from the shaft, slow flow, dissections, and perforations. Overall primary technical success rate was 93.3% and the secondary technical success rate was 96.7%. Detachment and slow flow occurred 14.4 and 4.4%, respectively, with no occurrences of either dissection or perforation. A predictor of detachment was Proposed Peripheral Arterial Calcium Scoring System (PACSS) grade 4 (OR 14.6; CI 1.26–168.5; P = 0.032). The Crosser catheter is useful not only as a CTO crossing device used with both the “Crosser preceding” and the “Guidewire preceding”, but also as a flossing device in stenotic lesions. But we have to pay attention to complications related to the Crosser.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Subscribe and save

Springer+ Basic
$34.99 /Month
  • Get 10 units per month
  • Download Article/Chapter or eBook
  • 1 Unit = 1 Article or 1 Chapter
  • Cancel anytime
Subscribe now

Buy Now

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Shin SH, Baril D, Chaer R, et al. Limitations of the Outback LTD re-entry device in femoropopliteal chronic total occlusions. J Vasc Surg. 2011;53:1260–4.

    Article  PubMed  Google Scholar 

  2. Joye J. The PATRIOT (peripheral approach to recanalization in occluded totals) study results. Am J Cardiol. 2007;100(Supp 1):S24.

    Google Scholar 

  3. Adam DJ, Bradbury AW. TASCII document on the management of peripheral artery disease. Eur J Vasc Endovasc Surg. 2007;33(1):1–2.

    Article  CAS  PubMed  Google Scholar 

  4. Staniloae CS, Mody KP, et al. Endoluminal treatment of peripheral chronic total occlusions using the Crosser recanalization catheter. J Invasive Cardiol. 2011;23:359–62.

    PubMed  Google Scholar 

  5. Gandini R, Volpi T, Pititone V, et al. Intraluminal recanalization of long infrainguinal chronic total occlusions using the Crosser system. J Endovasc Ther. 2009;16:23–7.

    Article  PubMed  Google Scholar 

  6. Igari K, Kudo T, Toyofuku T, Inoue Y, et al. A novel approach to infrainguinal arteries with chronic total occlusions using the high frequency vibrational device. Int Angiol. 2016;35(2):212–6.

    PubMed  Google Scholar 

  7. Khalid MR, Khalid FR, Farooqui FA, et al. A novel catheter in patients with peripheral chronic total occlusions: a single center experience. Catheter Cardiovasc Interv. 2010;76(5):735–9.

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Michinao Tan.

Ethics declarations

Conflict of interest

The authors declare no association with any individual, company, or organization having a vested interest in the subject matter/products mentioned in this article.

Human rights and ethical standards

This study was approved by the ethics committee of Tokeidai Memorial Hospital and written informed consents were obtained from patients.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Tan, M., Urasawa, K., Koshida, R. et al. Evaluation for the efficacy and safety of the crosser catheter as a CTO crossing device and a flossing device. Cardiovasc Interv and Ther 33, 77–83 (2018). https://doi.org/10.1007/s12928-016-0444-7

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12928-016-0444-7

Keywords

Navigation