Inappropriate Socket Shield Protocol as a Probable Cause of Peri-Implant Bone Resorption: A Case Report

  • Case Report
  • Published:
Journal of Maxillofacial and Oral Surgery Aims and scope Submit manuscript

Abstract

Alveolar ridge remodeling post-extraction is a well-documented process. Alveolar bone is in a continuous state of remodeling even after implant placement, and this leads to changes in the contour of the peri-implant tissues over the years. A vast number of procedures have been described in literature to address and correct this resorption including procedures like socket grafting, dual zone grafting, socket shield (partial extraction therapy) and many more. Socket shield (partial extraction therapy) is a relatively new procedure described in the literature. This technique aims to try and slow down this remodeling and maintain the peri-implant tissues in a state near normalcy. The aim of this article is to assess a case where the possible cause of buccal bone loss around an integrated implant was an inappropriately prepared socket shield. It is recommended that an evidence-based consensus be put forth on both case selection and execution to minimize inappropriate execution of this technique by the average clinician.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5

References

  1. Wöhrle PS (1998) Single-tooth replacement in the aesthetic zone with immediate provisionalization: fourteen consecutive case reports. Pract Periodontics Aesthet Dent 10:1107–1114

    PubMed  Google Scholar 

  2. Touati B, Guez G (2002) Immediate implantation with provisionalization: from literature to clinical implications. Pract Proced Aesthet Dent 14:699–707

    PubMed  Google Scholar 

  3. Kan JY, Rungcharassaeng K, Lozada J (2003) Immediate placement and provisionalization of maxillary anterior single implants: 1-year prospective study. Int J Oral Maxillofac Implants 18:31–39

    PubMed  Google Scholar 

  4. De Rouck T, Collys K, Cosyn J (2008) Single-tooth replacement in the anterior maxilla by means of immediate implantation and provisionalization: a review. Int J Oral Maxillofac Implants 23:897–904

    PubMed  Google Scholar 

  5. Huynh-Ba G, Meister DJ, Hoders AB, Mealey BL, Mills MP, Oates TW, Cochran DL, Prihoda TJ, McMahan CA (2016) Esthetic, clinical and patient-centered outcomes of immediately placed implants (Type 1) and early placed implants (Type 2): preliminary 3-month results of an ongoing randomized controlled clinical trial. Clin Oral Impl Res 27:241–252

    Article  Google Scholar 

  6. Jung RE, Kokovic V, Jurisic M, Yaman D, Subramani K, Weber FE (2011) Guided bone regeneration with a synthetic biodegradable membrane: a comparative study in dogs. Clin Oral Implants Res 22:802–807

    Article  Google Scholar 

  7. Da Rosa JC et al (2013) Immediate dentoalveolar restoration of compromised sockets: a novel technique. Eur J Esthet Dent 8(3):432–443

    PubMed  Google Scholar 

  8. Piattelli A, Trisi P, Romasco N, Emanuelli M (1993) Histological analysis of a screw implant retrieved from man: influence of early loading and primary stability. J Oral Implantol 19:303–306

    CAS  PubMed  Google Scholar 

  9. Hürzeler MB, Zuhr O, Schupbach P, Re-bele SF, Emmanouilidis N, Fickl S (2010) The socket-shield technique: a proof-of- principle report. J Clin Periodontol 37:855–862

    Article  Google Scholar 

  10. Chen C-L, Pan Y-H (2013) Socket Shield technique for ridge poreservation- a case report. J Prosthodont Implantol 2(2):16–21

    Google Scholar 

  11. Gluckman Howard, Toit Du, Salama M (2016) The pontic-shield: partial extraction therapy for ridge preservation and pontic site development. Int J Periodontics Restor Dent 36:417–423. https://doi.org/10.11607/prd.2651

    Article  Google Scholar 

  12. Han CH, Park KB, Mangano FG (2018) The modified socket shield technique. J Craniofac Surg 29(8):2247–2254. https://doi.org/10.1097/SCS.0000000000004494

    Article  PubMed  Google Scholar 

  13. Siormpas KD, Mitsias ME, Kontsiotou-Siormpa E, Garber D, Kotsakis GA (2014) Immediate implant placement in the esthetic zone utilizing the “root-membrane” technique: clinical results up to 5 years postloading. Int J Oral Maxillofac Implants 29:15. https://doi.org/10.11607/jomi.3707

    Article  Google Scholar 

  14. Mitsias M, Kontsiotou-Siormpa E, Garber D, Kotsakis GA (2014) Immediate implant placement in the esthetic zone utilizing the “root-membrane” technique: clinical results up to 5 years postloading. Int J Oral Maxillofac Implants 29(6):9

    Google Scholar 

  15. Geguzis A, Vaiciunaite E, Gervickas A (2018) The socket shield technique—a review. J Cont Med A Dent 6(3):4–8

    Google Scholar 

  16. Gharpure Amit, Bhatavadekar Neel (2016) Current evidence on the socket-shield technique: a systematic review. J Oral Implantol. https://doi.org/10.1563/aaid-joi-D-16-00174

    Article  Google Scholar 

  17. Gluckman Howard, Salama Maurice, DuToit J (2017) Partial extraction therapies (PET) Part 2: procedures and technical aspects. Int J Periodontics Restor Dent. 37:377–385

    Article  Google Scholar 

  18. Davarpanah M, Szmukler-Moncler S (2009) Unconventional implant treatment: I Implant placement in contact with ankylosed root fragments. A series of five case reports. Clin Oral Implants Res 20:851–856

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Yazad Gandhi.

Ethics declarations

Conflicts of interest

The authors declare that they have no conflict of interest.

Additional information

Publisher's Note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Gandhi, Y., Bhatavadekar, N. Inappropriate Socket Shield Protocol as a Probable Cause of Peri-Implant Bone Resorption: A Case Report. J. Maxillofac. Oral Surg. 19, 359–363 (2020). https://doi.org/10.1007/s12663-019-01301-1

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12663-019-01301-1

Navigation