Electrode pad suitability for repeated application to the head and neck

Abstract

Electrode pads are an integral component of ambulatory monitoring, providing an interface to conduct and record bioelectrical signals. During a previous clinical investigation involving our device for monitoring patients with dizziness, 53% of individuals experienced temporary redness and inflammation after wearing standard ECG electrode pads on the face for up to 30 days. We postulated that this was caused by a combination of the material composition of the electrode pads and through skin stripping due to their daily replacement. To test this hypothesis, we undertook a further study to determine which combination of electrode pad and replacement regime was most tolerable to the skin. Participants wore three different electrode pads on both sides of their face for 30 days. Electrode pads on the left were replaced daily, and those on the right on alternate days. Participants were instructed to inspect their skin after removal and to not reapply a new electrode pad if they noticed any unexpected changes to the condition of their skin. Electrode pad performance was measured by the duration of wear. The two best performing electrode pads contained a wet gel rather than a solid, adhesive gel, but the advantage of replacing electrode pads on alternate days was negligible. The chloride concentration of the gels was found to be likely factor in determining tolerability. The results suggest that optimal tolerability for ambulatory monitoring on the head and neck is provided by electrode pads containing a wet gel and a low chloride concentration.

This is a preview of subscription content, access via your institution.

Fig. 1
Fig. 2

References

  1. Baig MM, GholamHosseini H, Moqeem AA, Mirza F, Lindén M. A systematic review of wearable patient monitoring systems – current challenges and opportunities for clinical adoption. J Med Syst. 2017;41:115. https://doi.org/10.1007/s10916-017-0760-1.

    Article  Google Scholar 

  2. Im C, Seo J-M. A review of electrodes for the electrical brain signal recording. Biomed Eng Lett. 2016;6:104–12. https://doi.org/10.1007/s13534-016-0235-1.

    Article  Google Scholar 

  3. Phillips JS, Newman JL, Cox SJ. An investigation into the diagnostic accuracy, reliability, acceptability and safety of a novel device for continuous ambulatory vestibular assessment (CAVA). Sci Rep. 2019;9:10452. https://doi.org/10.1038/s41598-019-46970-7.

    Article  Google Scholar 

  4. Marozas V, Petrenas A, Daukantas S, Lukosevicius A. A comparison of conductive textile-based and silver/silver chloride gel electrodes in exercise electrocardiogram recordings. J Electrocardiol. 2011;44:189–94. https://doi.org/10.1016/j.jelectrocard.2010.12.004.

    Article  Google Scholar 

  5. Tam H, Webster JG. Minimizing electrode motion artifact by skin abrasion. IEEE Trans Biomed Eng. 1977;BME-24:134–9. https://doi.org/10.1109/TBME.1977.326117.

    Article  Google Scholar 

  6. Hoon Lee J, Min Lee S, Jin Byeon H, Sook Hong J, Suk Park K, Lee SH. CNT/PDMS-based canal-typed ear electrodes for inconspicuous EEG recording. J Neural Eng. 2014;11:046014. https://doi.org/10.1088/1741-2560/11/4/046014.

    Article  Google Scholar 

  7. Rühlemann D, Kügler K, Mydlach B, Frosch PJ. Contact dermatitis to self-adhesive ECG electrodes. Contact Dermatitis. 2010;62:314–5. https://doi.org/10.1111/j.1600-0536.2010.01718.x.

    Article  Google Scholar 

  8. Weber-Muller F, Reichert-Penetrat S, Schmutz J-L, Barbaud A. Contact dermatitis from polyacrylate in TENS electrode. Ann Dermatol Venereol. 2004;131:478–80. https://doi.org/10.1016/s0151-9638(04)93644-7.

    Article  Google Scholar 

  9. Rippon M, White R, Davies P. Skin adhesives and their role in wound dressings. Wounds UK. 2007;3:76.

    Google Scholar 

  10. Baek J-Y, An J-H, Choi J-M, Park KS, Lee SH. Flexible polymeric dry electrodes for the long-term monitoring of ECG. Sensors Actuators A Phys. 2008;143:423–9. https://doi.org/10.1016/j.sna.2007.11.019.

    Article  Google Scholar 

  11. Gandhi N, Khe C, Chung D et al (2011) Properties of dry and non-contact electrodes for wearable physiological sensors. In: 2011 international conference on body sensor networks, pp 107–112

Download references

Acknowledgements

This work is funded by the Medical Research Council (MRC) as part of MR/P026265/1, but the MRC were not involved in any other aspect of producing this manuscript.

Funding

This work is funded by the Medical Research Council (MRC) as part of MR/P026265/1.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to John S. Phillips.

Ethics declarations

Conflicts of interest/competing interests

We have no relevant competing interests to declare.

Ethics approval (include appropriate approvals or waivers)

This study was reviewed and approved by the London – South East Research Ethics Committee (19/LO/0487, IRAS: 261103).

Consent to participate (include appropriate statements)

Not applicable.

Consent for publication (include appropriate statements)

Not applicable.

Availability of data and material (data transparency)

All data used in this study is available upon reasonable request.

Code availability (software application or custom code)

Not applicable.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and Permissions

About this article

Verify currency and authenticity via CrossMark

Cite this article

Phillips, J.S., Newman, J., Garioch, J. et al. Electrode pad suitability for repeated application to the head and neck. Health Technol. 10, 1325–1329 (2020). https://doi.org/10.1007/s12553-020-00444-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12553-020-00444-3

Keywords

  • Ambulatory monitoring
  • Electrode pads
  • Physiological monitoring