Abstract
Surface texture technique increases the tribological capability and performance of bearing surfaces. This technology has a number of applications, including car engines and golf balls. However, the use of texture surface in artificial hip joints has not been adequately explored. The aim of the study is to investigate the effects of plateau honed surfaces on the tribological performance of metal-on-metal hip joints. Four sets of different plateau honed surfaces and a set of non-textured surface were investigated on a friction simulator with a lubricant having similar viscosity of pseudo-synovial fluid. The results showed 50% and 38% reductions in static and dynamic friction coefficient, respectively, for a honed surface (honed surface 3) compared with those of a non-textured surface after 1 million cycles. There was a number of wear signs, including adhesive and fatigue wear in all of the experimental surfaces. Nevertheless, the wear signs in the honed surface 3 were minor. Lubrication film thickness was thicker, and third body abrasive wear assumed to reduce in the honed surface since wear debris removed through honed channel. Therefore, the performance of a well-designed plateau-honed surface is significant in tribological aspects of metal-on-metal hip joints.
Similar content being viewed by others
References
National Joint Registry, “National Joint Registry for England and Wales, 7th Annual Report 2010,” http://www.njrcentre.org.uk/njrcentre/portals/0/njr%207th%20annual%20report%202010.pdf (Accessed 05 Jan, 2013)
Bozic, K. J., Ong, K., Lau, E., Kurtz, S. M., Vail, T. P., Rubash, H. E., and Berry, D. J., “Risk of Complication and Revision Total Hip Arthroplasty Among Medicare Patients with Different Bearing Surfaces,” Clin Orthop Relat Res, Vol. 468, pp. 2357–2362, 2010.
Macfarlane, J., “10,000 hip replacement patients told their operations may need to be reversed after receiving faulty implants,” in Daily Mail online: London, UK, 2010.
Smith, A. J., Dieppe, P., Porter, M., and Blom, A. W., “Risk of cancer in first seven years after metal-on-metal hip replacement compared with other bearings and general population: linkage study between the National Joint Registry of England and Wales and hospital episode statistics,” Brit Med J, Vol. 344, pp. 1–1, 2012.
Mäkelä, K. T., Eskelinen, A., Pulkkinen, P., Paavolainen, P., and Remes, V., “Results of 3,668 primary total hip replacements for primary osteoarthritis in patients under the age of 55 years,” Acta orthopaedica, Vol. 82, No. 5, pp. 521–529, 2011.
Jhurani, S. M. and Fred Higgs, C., “An elastohydrodynamic lubrication (EHL) model of wear particle migration in an artificial hip joint,” Tribol Int, Vol. 43, No. 8, pp. 1326–1338, 2010.
W Puhl, S. K., “Which factors influence the long term outcome of total hip replacement? In: C. Rieker, S. Oberholzer, W. Urs (eds),” World Tribology Forum in Arthroplasty. Hans Huber, Bern, pp. 35–47, 2001.
Katti, K. S., “Biomaterials in total joint replacement,” Colloids and surfaces. B, Biointerfaces, Vol. 39, No. 3, pp. 133–142, 2004.
Dowson, D., Hardaker, C., Flett, M., and Isaac, H. G., “Hip Joint Simulator Study of the Performance of Metal-on-Metal Joints, Part I: The Role of Materials. 19,” J Arthroplasty, Vol. 19, pp. 118–123, 2004.
Dowson, D., Hardaker, C., Flett, M., and Isaac, G. H., “A hip joint simulator study of the performance of metal-on-metal joints: Part II: design,” J Arthroplasty, Vol. 19, No. 8, Suppl 3, pp. 124–130, 2004.
Verheyen, C. C. P. M. and Verhaar, J. A. N., “Failure rates of stemmed metal-on-metal hip replacements,” J Bone Joint Surg Br, Vol. 93, pp. 298–306, 2011.
Gandhe, A. and Grover, M., “(i) Head size, does it matter?,” Current Orthopedics, pp. 155–164, Vol. 22, 2008.
Huang, W., Jiang, L., Zhou, C. X., and Wang, X. L., “The lubricant retaining effect of micro-dimples on the sliding surface of PDMS,” Tribol Int, Vol. 52, pp. 87–93, 2012.
Krupka, I., Hartl, M., Zimmerman, M., Houska, P., and Jang, S., “Effect of surface texturing on elastohydrodynamically lubricated contact under transient speed conditions,” Tribol Int, Vol. 44, No. 10, pp. 1144–1150, 2011.
Mezghani, S., Demirci, I., Zahouani, H., and Mansori, M. E., “The effect of groove texture patterns on piston-ring pack friction,” Precis Eng, Vol. 36, No. 2, pp. 210–217, 2012.
Pawlus, P., Cieslak, T., and Mathia, T., “The study of cylinder liner plateau honing process,” J Mater Process Tech, Vol. 209, No. 20, pp. 6078–6086, 2009.
Gao, L., Yang, P., Dymond, I., Fisher, J., and Jin, Z., “Effect of surface texturing on the elastohydrodynamic lubrication analysis of metal-on-metal hip implants,” Tribol Int, Vol. 43, No. 10, pp. 1851, 2010.
Ito, H., Kaneda, K., Yusta, T., Nishimura, I., Yasuda, K., and Matsuno, T., “Reduction of polyethylene wear by concave dimples on the frictional surface in artificial hip joints,” J Arthroplasty, Vol. 15, No. 3, pp. 332–338, 2000.
Sawanoa, H., Warisawab, S., and Ishiharab, S., “Study on long life of artificial joints by investigating optimal sliding surface geometry for improvement in wear resistance,” Precis Eng, Vol. 33, pp. 492–498, 2009.
http://www.shorewestern.com/DOCUMENTS/Hip.pdf (accessed 27/09/2012)
Bergmann, G., Deuretzbacher, G., Hellerc, M., Graichen, F., Rohlmann, A., Strauss, J., and Duda, G. N., “Hip contact forces and gait patterns from routine activities,” J Biomech, Vol. 34, No. 7, pp. 859–871, 2001.
Oliveiraa, A. L. L., Limaa, R. G., Cuevab, E. G., and Queirozc, R. D., “Comparative analysis of surface wear from total hip prostheses tested on a mechanical simulator according to standards ISO 14242-1 and ISO 14242-3,” Wear, Vol. 271, pp. 2340–2345, 2011.
Jebens, E. H., and Eileen, M. M. J., “On the Viscosity and Ph of synovial fluid and the Ph of blood,” The journal of bone and joint surgery, Vol. 41-B, No. 2, pp. 388–400, 1959.
Larkin, G. J., Lowe, D. O. G., and Sturrock, D. R., “The correlation of clinical assessment of synovial fluid with its measure viscosity,” BRIT J RHEUMATOL, Vol. 23, pp. 195–197, 1984.
Pawlak, Z., Kotynska, J., Figaszewski, Z. A., Oloyede, A., Gadomski, A., and Gudaniec, A., “Impact of the charge density of phospholipid bilayers on lubrication of articular cartilage surfaces,” Journal of Achievements in Materials and Manufacturing Engineering, Vol. 23, No. 1, pp. 47–51, 2007.
Dimkovski, Z., “Characterization of a cylinder liner surface by roughness parameter analysis,” Blekinge Institute of Technology, Karlskrona, Sweden, 2006.
Stachowiak, G. W. and Batchelor, A. W., “Engineering Tribology,” Butterworth-Heinemann Publication, 2nd edn., 2001.
Mow, V. C. and Huiskes, R., “Basic Orthopaedics and Mechano-Biology,” William and Wilkins, 3rd edn., 2005.
Mattei, L., Puccio, F. D., Piccigallo, B., and Ciulli, E., “Lubrication and wear modelling of artificial hip joints: A review,” Tribol Int, Vol. 44, No. 5, pp. 532–549, 2011.
Hu, T., Hu, L., and Dinga, Q., “Effective solution for the tribological problems of Ti-6Al-4V: Combination of laser surface texturing and solid lubricant film,” Surf Coat Tech, Vol. 2006, No. 24, pp. 5060–5066, 2012.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Choudhury, D., Walker, R., Roy, T. et al. Performance of honed surface profiles to artificial hip joints: An experimental investigation. Int. J. Precis. Eng. Manuf. 14, 1847–1853 (2013). https://doi.org/10.1007/s12541-013-0247-z
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12541-013-0247-z