Abstract
Background
The “Controlled Aliasing In Parallel Imaging Results In Higher Acceleration” (CAPIRINHA) technique greatly accelerates T1w 3D fast low angle shot (FLASH) scans while maintaining high image quality. We studied image quality and conspicuity of inflammatory lesions on CAIPIRINHA-accelerated imaging for pediatric small-bowel magnetic resonance imaging (MRI).
Methods
Forty-four consecutive patients (mean 14±3 years, 18 girls) underwent small-bowel MRI (MR enterography, MRE) at 1.5 T including diffusion-weighted imaging (DWI), contrast-enhanced CAIPIRINHA 3D-FLASH and standard 2D-FLASH imaging. Crohn’s disease (CD) was confirmed in 26 patients, 18 patients served as control. Independent blinded readings were performed for grading of image quality and conspicuity of CD lesions on CAIPIRINHA FLASH and standard FLASH images in comparison to a reference standard comprising imaging and endoscopic data.
Results
CAIPIRINHA FLASH yielded significantly higher image quality with good inter-observer agreement (κ=0.68) and showed better visual delineation in 40% of the assessed bowel lesions, as compared to standard FLASH. There was full agreement for identification of CD patients between CAIPIRINHA and standard FLASH. CAIPIRINHA FLASH detected two small-bowel lesions that were not seen on standard FLASH. DWI revealed additional inflammatory lesions inconspicuous on contrast-enhanced imaging. MRE showed an overall diagnostic accuracy of 93%.
Conclusion
We present first evidence that CAIPIRINHA greatly accelerates T1w imaging in paediatric MRE without trade-off in image quality or lesion conspicuity and is thus preferable to standard FLASH imaging.
Similar content being viewed by others
References
Loftus EV. Clinical epidemiology of inflammatory bowel disease: Incidence, prevalence, and environmental influences. Gastroenterol 2004;126:1504–1517.
Diefenbach KA, Breuer CK. Pediatric inflammatory bowel disease. World J Gastroenterol 2006;12:3204–3212.
Alison M, Kheniche A, Azoulay R, Roche S, Sebag G, Belarbi N. Ultrasonography of Crohn disease in children. Pediatr Radiol 2007;37:1071–1082.
Gore RM, Balthazar EJ, Ghahremani GG, Miller FH. CT features of ulcerative colitis and Crohn’s disease. AJR Am J Roentgenol 1996;167:3–15.
Brenner DJ. Should computed tomography be the modality of choice for imaging Crohn’s disease in children? The radiation risk perspective. Gut 2008;57:1489–1490.
Darge K, Anupindi SA, Jaramillo D. MR Imaging of the Abdomen and Pelvis in Infants, Children, and Adolescents. Radiology 2011;261:12–29.
Gee MS, Nimkin K, Hsu M, Israel EJ, Biller JA, Katz AJ, et al. Prospective evaluation of MR enterography as the primary imaging modality for pediatric Crohn’s disease assessment. AJR Am J Roentgenol 2011;197:224–231.
Alliet P, Desimpelaere J, Hauser B, Janssens E, Khamis J, Lewin M, et al. MR enterography in children with Crohn disease: results from the Belgian pediatric Crohn registry (Belcro). Acta Gastroenterol Belg 2013;76:45–48.
Borthne AS, Abdelnoor M, Rugtveit J, Perminow G, Reiseter T, Klow NE. Bowel magnetic resonance imaging of pediatric patients with oral mannitol MRI compared to endoscopy and intestinal ultrasound. Eur Radiol 2006;16:207–214.
Horsthuis K, de Ridder L, Smets AM, van Leeuwen MS, Benninga MA, Houwen RH, et al. Magnetic resonance enterography for suspected inflammatory bowel disease in a pediatric population. J Pediatr Gastroenterol Nutr 2010;51:603–609.
Casciani E, Masselli G, Di Nardo G, Polettini E, Bertini L, Oliva S, et al. MR enterography versus capsule endoscopy in paediatric patients with suspected Crohn’s disease. Eur Radiol 2011;21:823–831.
Chalian M, Ozturk A, Oliva-Hemker M, Pryde S, Huisman TA. MR Enterography Findings of Inflammatory Bowel Disease in Pediatric Patients. AJR Am J Roentgenol 2011;196:W810–W816.
Li M, Winkler B, Pabst T, Bley T, Köstler H, Neubauer H. Fast MR imaging of the paediatric abdomen with CAIPIRINHAaccelerated T1w 3D-FLASH and with high-resolution T2w HASTE: a study on image quality. Gastroenterol Res Pract 2015;2015:693654.
Breuer FA, Blaimer M, Heidemann RM, Mueller FM, Griswold MA, Jakob PM. Controlled aliasing in parallel imaging results in higher acceleration (CAIPIRINHA) for multi-slice imaging. Magn Reson Med 2005;53:684–691.
Riffel P, Attenberger UI, Kannengiesser S, Nickel MD, Arndt C, Meyer M, et al. Highly Accelerated T1-Weighted Abdominal Imaging Using 2-Dimensional Controlled Aliasing in Parallel Imaging Results in Higher Acceleration. Invest Radiol 2013;48:554–561.
Yu MH, Lee JM, Yoon JH, Kiefer B, Han JK, Choi BI. Clinical application of controlled aliasing in parallel imaging results in a higher acceleration (CAIPIRINHA)-volumetric interpolated breathhold (VIBE) sequence for gadoxetic acid-enhanced liver MR imaging. J Magn Reson Imaging 2013;38:1020–1026.
Park YS, Lee CH, Kim IS, Kiefer B, Woo ST, Kim KA, et al. Usefulness of controlled aliasing in parallel imaging results in higher acceleration in gadoxetic acid-enhanced liver magnetic resonance imaging to clarify the hepatic arterial phase. Invest Radiol 2014;49:183–188.
Morani AC, Vicens RA, Wei W, Gupta S, Vikram R, Balachandran A, et al. CAIPIRINHA-VIBE and GRAPPA-VIBE for liver MRI at 1.5 T: a comparative in vivo patient study. J Comput Assist Tomogr 2015;39:263–269.
Neubauer H, Pabst T, Dick A, Machann W, Evangelista L, Wirth C, et al. Small-bowel MRI in children and young adults with Crohn disease: retrospective head-to-head comparison of contrast-enhanced and diffusion-weighted MRI. Ped Radiol 2013;43:103–114.
Siddiki H, Fidler J. MR imaging of the small bowel in Crohn’s disease. Eur J Radiol 2009;69:409–417.
Breuer FA, Blaimer M, Mueller MF, Seiberlich N, Heidemann RM, Griswold MA, et al. Controlled Aliasing in Volumetric Parallel Imaging (2D CAIPIRINHA). Magn Reson Med 2006;55:549–556.
Alexopoulou E, Roma E, Loggitsi D, Economopoulos N, Papakonstantinou O, Panagiotou I, et al. Magnetic resonance imaging of the small bowel in children with idiopathic inflammatory bowel disease: evaluation of disease activity. Pediatr Radiol 2009;39:791–797.
Oussalah A, Laurent V, Bruot O, Bressenot A, Migard MA, Regent D, et al. Diffusion-weighted magnetic resonance without bowel preparation for detecting colonic inflammation in inflammatory bowel disease. Gut 2010;59:1056–1065.
Ream JM, Dillman JR, Adler J, Khalatbari S, McHugh JB, Strouse PJ, et al. MRI diffusion-weighted imaging (DWI) in pediatric small bowel Crohn disease: correlation with MRI findings of active bowel wall inflammation. Pediatr Radiol 2013;43:1077–1085.
Sakuraba H, Ishiguro Y, Hasui K, Hiraga H, Fukuda S, Shibutani K, et al. Prediction of Maintained Mucosal Healing in Patients with Crohn’s Disease under Treatment with Infliximab Using Diffusion-Weighted Magnetic Resonance Imaging. Digestion 2014;89:49–54.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Li, M., Dick, A., Hassold, N. et al. CAIPIRINHA-accelerated T1w 3D-FLASH for small-bowel MR imaging in pediatric patients with Crohn’s disease: assessment of image quality and diagnostic performance. World J Pediatr 12, 455–462 (2016). https://doi.org/10.1007/s12519-016-0047-5
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12519-016-0047-5