Abstract
Recent advances in myocardial perfusion single photon emission computed tomography (SPECT) processing software, incorporating iterative reconstruction, resolution recovery, and noise compensation, now provide the ability to acquire high quality scans despite reduced administered activity, shortened acquisition time, or both. These methods have thereby provided imaging protocol flexibility and facilitated patient-centered imaging. Other software methods allow for improved image quality by prescribing an image acquisition time that will yield optimal SPECT image count density. On some new solid state cameras list mode acquisition is now available, whereby suboptimal acquisition stops such as those with patient motion can be eliminated prior to SPECT reconstruction. Still other methods, incorporating phase analysis of gated perfusion SPECT, provide a quantitative analysis of left ventricular dyssynchrony, aiding in the selection of patients for whom cardiac resynchronization therapy is most beneficial.
Similar content being viewed by others
References
Papers of particular interest, published recently, have been highlighted as: • Of importance •• Of major importance
Patton JA, Slomka PJ, Germano G, Berman DS. Recent technological advances in nuclear cardiology. J Nucl Cardiol. 2007;14:501–13.
• Garcia EV, Faber TL. New trends in camera and software technology in nuclear cardiology. Cardiol Clin. 2009;27:227–36. This review article explains the theory and implementation of new scintillation cameras for myocardial perfusion SPECT and the introduction of new software methods for SPECT reconstruction.
DePuey EG. New software methods to cope with reduced counting statistics: shorter SPECT acquisitions and many more possibilities. J Nucl Cardiol. 2009;16:335–8.
•• DePuey EG. Advances in SPECT camera software and hardware: currently available and new on the horizon. J Nucl Cardiol. 2012;19:551–81. This review article provides an in-depth explanation of new myocardial perfusion SPECT hardware and software methods and recent clinical results.
Metz CE. The geometric transfer function component for scintillation camera collimators with straight parallel holes. Phys Med Biol. 1980;25:1059–70.
Tsui BMW, Gullberg GT. The geometric transfer-function for cone and fan beam collimators. Phys Med Biol. 1990;35:81–93.
Tsui BMW, Hu HB, Gillard DR, Gullberg GT. Implementation of simultaneous attenuation and detector response correction in SPECT. IEEE Trans Nucl Sci. 1988;35:778–83.
Tsui BMW, Frey EC, Zhao X, Lalush DS, Johnston RE, McCartney WH. The importance and implementation of accurate 3-dimensional compensation methods for quantitative SPECT. Phys Med Biol. 1994;39:509–30.
Tsui BMW, Zhao XD, Frey EC, Gullberg GT. Characteristics of reconstructed point response in 3-dimensional spatially variant detector response compensation in SPECT. In: Grangeat P, Amans J-L, editors. Three-dimensional image reconstruction in radiology and nuclear medicine. Kluwer. Dordrecht: Academic Publishers; 1996. p. 509–30.
Borges-Neto S, Pagnanelli RA, Shaw LK, Honeycutt E, Shwartz SC, Adams GL, et al. Clinical results of a novel wide beam reconstruction method for shortenings can time of Tc-99m cardiac SPECT perfusion studies. J Nucl Cardiol. 2007;14:555–65.
Venero CV, Heller GV, Bateman TM, McGhie AI, Ahlberg AW, Katten D, et al. A multicenter evaluation of a new postprocessing method with depth-dependent collimator resolution applied to full-time and half-time acquisitions without and with simultaneously acquired attenuation correction. J Nucl Cardiol. 2009;16:714–25.
DePuey EG, Gadiraju R, Clark J, Thompson L, Anstett F, Shwartz SC. Ordered subset expectation that maximization and wide beam reconstruction "half-time" gated myocardial perfusion SPECT functional imaging: a comparison with "full-time" filtered backprojection. J Nucl Cardiol. 2008;15:547–63.
DePuey EG, Bommireddipalli S, Clark J, Thompson L, Srour Y. Wide beam reconstruction “quarter-time” gated myocardial perfusion SPECT functional imaging: a comparison with “full-time” ordered subset expectation maximum. J Nucl Cardiol. 2009;16:736–52.
DePuey EG, Bommireddipalli S, Clark J, Leykekhman A, Thompson LB, Friedman M. A comparison of the image quality of full-time myocardial perfusion SPECT vs wide beam reconstruction half-time and half-dose SPECT. J Nucl Cardiol. 2011;18:273–80.
Chen J, Garcia EV, Folks RD, Cooke CD, Faber TL, Tauxe L, et al. Onset of left ventricular mechanical contraction as determined by phase analysis of ECG-gated myocardial perfusion SPECT imaging: development of a diagnostic tool for assessment of cardiac mechanical dyssynchrony. J Nucl Cardiol. 2005;12:687–95.
Henneman MM, Chen J, Dibbets-Schneider P, Stokkel MP, Bleeker GB, Ypenburg C, et al. Can LV dyssynchrony as assessed with phase analysis on gated myocardial perfusion SPECT predict response to CRT? J Nucl Med. 2007;48:1104–11.
Esteves FP, Raggi P, Folks RD, Keidar Z, Askew W, Rispler S, et al. Novel solid- state-detector dedicated cardiac camera for fast myocardial perfusion imaging: multicenter comparison with standard dual detector cameras. J Nucl Cardiol. 2009;16:927–34.
Erlandsson K, Kacperski K, Van Gramberg D, Hutton B. Performance evaluation of D-SPECT: a novel dedicated cardiac SPECT scanner. Phys Med Biol. 2009;54:2635–2649.
Hutton B, Erlandsson K, Kacperski K, Van Gramberg D, Roth N. Performance evaluation of D-SPCT: a novel dedicated cardiac SPECT scanner. J Nucl Med. 2008;49 Suppl 1:124P.
Sharir T, Ben-Haim S, Merzon K, Prochorov V, Dickman D, Ben-Haim S, et al. High-speed myocardial perfusion imaging: initial clinical comparison with conventional dual detector anger camera imaging. J Am Coll Cardiol Imaging. 2008;1:156–63.
Sharir T, Slomka PJ, Hayes SW, DiCarli MF, Ziffer JA, Martin WH, et al. Multicenter trial of high-speed vs conventional single-photon emission computed tomography imaging: quantitative of myocardial perfusion and left ventricular function. J Am Coll Cardiol. 2010;55:1965–74.
Corbett J, Meden J, Ficaro E. Clinical validation of attenuation corrected cardiac imaging with IQ-SPECT/CT [abstract]. J Nucl Med. 2010;4(Suppl):733.
Maddahi J, Mendez R, Mahmarian J, Thomas G, Bai C, Babla H, et al. Prospective multicenter evaluation of rapid gated SPECT myocardial perfusion and upright imaging. J Nucl Cardiol. 2009;16:351–7.
Duvall WL, Croft LB, Godiwala T, Ginsberg E, George T, Henzlova MJ. Reduced isotope dose with rapid SPECT MPI imaging: Initial experience with a CZT SPECT camera. J Nucl Cardiol. 2010;17:1009–14.
Conflict of Interest
E. Gordon DePuey has been a consultant to UltraSPECT Ltd.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
DePuey, E.G. New Software Solutions for Cardiac SPECT Imaging. Curr Cardiovasc Imaging Rep 6, 314–321 (2013). https://doi.org/10.1007/s12410-013-9204-6
Published:
Issue Date:
DOI: https://doi.org/10.1007/s12410-013-9204-6