Abstract

External Quality Assessment Scheme (EQAS) involves evaluation of a number of laboratories by an outside agency on the performance of a number of laboratories based on their analytical performance of tests on samples supplied by the external agency. In developing countries, establishment of national EQAS by preparing homemade quality control material is a useful scheme in terms of resources and time to monitor the laboratory performance. The objective of this study is to implement an EQAS to monitor the analytical performance of the district laboratories in Bhutan. Baseline information was collected through questionnaires. Lyophilized human serum including normal and abnormal levels were prepared and distributed to 19 participating laboratories. Nine routine analytes were included for the study. Their results were evaluated using Variance index scores (VIS) and Coefficient of variations (CV) was compared with Clinical Laboratory Improvement Act (CLIA) Proficiency Testing Criteria (PT) for each analyte. There was significant decrease in CV at the end of the study. The percentages of results in acceptable VIS as ‘A’ were 63, 60, 66, 69, 73 and 74, 75, 76 and 79 % in November 2009–July 2010 respectively. From our results, we concluded that, establishment of EQAS through distribution of home-made quality control material could be the useful scheme to monitor the laboratory performance in clinical chemistry in Bhutan.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Sciacovelli L, Zardo L, Secchiero S, Plebani M. Quality specifications in EQAS: from theory to practice. Clin Chim Acta. 2004;346:87–97.

    Article  PubMed  CAS  Google Scholar 

  2. Ministry of Health, Bhutan. Report of the national health survey. [Online]. http://www.health.gov.bt/healthsurvey2000.pdf (2000). Accessed on 20 Feb 2000.

  3. Ministry of health, Bhutan. Quality assurance and standardization. [Online]. http://www.health.gov.bt/qasd.php (2008). Accessed 20 May 2009.

  4. Maurukas J. Process for preparing biologic composition for use as a reference control in diagnostic analyses. US Patent 4121,905, 1978.

    Google Scholar 

  5. Prijavudhi A. Production and acquisition of control sample. [Online]. http://www.eqacenter.com/2010_04_11_archive.html (2010). Accessed 13 June 2010.

  6. Özbek B and Karavelioğlu H. Studies on the stability of various components of control serums prepared in lyophilized form. [Online]. www.sigma.yildiz.edu.tr/2001-1-4-tam.DOC (2010). Accessed 13 Aug 2010.

  7. Deom A, Aouad RE, Heuck CC, Kumari S, Lewis SM, Uldall A, Wardle J. Requirements and guidance for external quality assessment schemes for the health laboratory. 2nd ed. Geneva: WHO; 1999. p. 1–65.

    Google Scholar 

  8. UK NEQAS. Program for immunology and immunochemistry 2006–2007. [Online]. http://www.immqas.org.uk/docs/Scheme%20Handbook%202006-07.pdf (2010). Accessed 18 July 2010.

  9. WHO. Preparation of stabilized liquid quality control serum to be used in clinical chemistry (WHO documents Lab/86.4). [Online]. http://whqlibdoc.who.int/hq/198586/LAB_86.4.pdf (1986). Accessed 6 Aug 2009.

  10. Thompson M, Ellison SLR, Wood R. The international harmonized protocol for the proficiency testing of analytical chemistry. IUPAC. 2006;78(1):45–96.

    Google Scholar 

  11. Smith AF, Fogg BA. Possible mechanisms for the increase in alkaline phosphatase activity of lyophilized control material. Clin Chem. 1972;18(12):1518–23.

    PubMed  CAS  Google Scholar 

  12. Boyanton BL Jr, Blick KE. Stability studies of 24 analytes in human plasma and serum. Clin Chem. 2002;48(12):2242–7.

    PubMed  CAS  Google Scholar 

  13. Marjani A. Effect of storage time and temperature on serum analytes. Am J Appl Sci. 2008;5(8):1047–51.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Rixin Jamtsho.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Jamtsho, R., Nuchpramool, W. Implementation of External Quality Assessment Scheme in Clinical Chemistry for District Laboratories in Bhutan. Ind J Clin Biochem 27, 300–305 (2012). https://doi.org/10.1007/s12291-012-0204-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s12291-012-0204-0

Keywords

Navigation